검색결과 5,067건 처리시간 0.031초

사육수의 고수온 스트레스가 벤자리(Parapristipoma trilineatum)에 미치는 생리학적 영향 (Physiological Responses of the Chicken Grunt Parapristipoma trilineatum to High Water Temperature Stress)

  • 김기혁;홍성원;문혜나;여인규
    • 한국수산과학회지
    • /
    • 제51권6호
    • /
    • pp.714-719
    • /
    • 2018
  • We investigated the effects of water temperature on physiological parameters in the chicken grunt Parapristipoma trilineatum. At high temperature, the aspartate aminotransferase (AST) and the alanine aminotransferase (ALT) levels were increased, suggesting that high temperature induced hepatic damage. In addition, total protein (TP) was high at high water temperatures, which were considered stressful in the breeding environment. At high water temperatures, triglycerides (TG) were low due to increased metabolic activity, which decreased the blood TG levels as TG were used as an energy source. There was no significant difference in the plasma osmolality or the blood ion concentrations with water temperature. In generally, lysozyme, a factor in innate immunity, increased with water temperature. However, lysozyme activity tended to decrease with increasing water temperature, but the difference was not significant. These results suggested that the decrease of biophylaxis at high temperature was affect the growth or survival of the population.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 1 The effects of heating temperatures and testing conditions (hot and cold)

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제2권2호
    • /
    • pp.145-162
    • /
    • 2014
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was determined by conducting three-point bending tests on eighty notched HPC beams of $500mm{\times}100mm{\times}100mm$ at high temperatures up to $450^{\circ}C$ (hot) and in cooled-down states (cold). When the concrete beams exposed to high temperatures for 16 hours, both thermal and hygric equilibriums were generally achieved. $K_{IC}$ for the hot concrete sustained a monotonic decrease tendency with the increasing temperature, with a sudden drop at $105^{\circ}C$. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and rapidly thereafter. The fracture energy-based fracture toughness $K_{IC}$' was found to follow similar decrease trends with the heating temperature. The weight loss, the fracture energy and the modulus of rapture were also evaluated.

산성 염화물 환경에서 F53 슈퍼 듀플렉스 스테인리스강의 2 상간의 공식 거동 연구 (Investigation of the pitting corrosion behavior between the constituent phases in F53 super duplex stainless steel in acidified chloride environments)

  • 김순태;공경호;이인성;박용수;이종훈;김두현
    • Corrosion Science and Technology
    • /
    • 제13권3호
    • /
    • pp.95-101
    • /
    • 2014
  • The pitting corrosion behaviors between the constituent phases in F53 super duplex stainless steel (SDSS) in acidified chloride environments were investigated using a critical pitting corrosion temperature test, a potentiodynamic anodic polarization test, and the microstructure analyses through a SEM-EDS and a SAM. As the solution annealing temperature decreased from $1150^{\circ}C$ to $1050^{\circ}C$, the ${\gamma}$-phase fraction increased whereas the ${\alpha}$-phase fraction decreased. The pitting potential and the critical pitting temperature increased with a decrease of solution annealing temperature, thereby increasing the resistance to pitting corrosion. The pitting corrosion of the SDSS was selectively initiated at the ${\alpha}$-phases because the PREN (pitting resistance equivalent number, PREN = %Cr+3.3%Mo+30%N) value of the ${\gamma}$-phase is much larger than that of the ${\alpha}$-phase, irrespective of the solution annealing temperature. The pitting corrosion was finally propagated from the ${\alpha}$-phase to the ${\gamma}$-phase. The decrease of solution annealing temperature enhanced the resistance to pitting corrosion greatly in acidified chloride environments due to a decrease of PREN difference between the ${\gamma}$-phase and the ${\alpha}$-phase, that is, a decrease of $PREN{\gamma}$ by dilution of N in ${\gamma}$-phase with an increase in the ${\gamma}$-phase volume fraction and an increase of $PREN{\alpha}$ by enrichment of Cr and Mo in the ${\alpha}$-phase with a decrease in the ${\alpha}$-phase volume fraction.

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.

Differential Effects of Cotton and Polyester Ensembles on Changes in Clothing Surface Temperature, Skin Temperature and Skin Blood Flow During Heat Load

  • Tanaka, Kaori;Hirata, Kozo
    • 한국의류산업학회지
    • /
    • 제2권5호
    • /
    • pp.405-410
    • /
    • 2000
  • The effects of individual sweating rates on thermophysiological responses during the decrease phase of clothing surface temperature (Tcs) with cotton (C) and polyester (P) clothed subjects were examined. Seven women subjects were exposed in a climatic chamber at ambient temperature of $27.2^{\circ}C$, relative humidity of 50%, and their lower-legs were immersed in a water bath at a temperature of $35-41^{\circ}C$ for 70 min. During water immersion, Tcs in C-clothed subject rose immediately after the onset of sweating and then Tcs fell gradually. In C-clothed subjects, Tcs decreased directly (p<0.05) in proportion to total sweating rate (TSR), however no significant correlation was observed in P-clothed subjects. The relationship between TSR and changes in mean skin temperature, and skin blood flow showed negative correlation when wearing C-clothing (p<0.05), however, no significant correlation when wearing P-clothing. Individual TSR was correlated with threshold rectal temperature for sweating onset (p<0.05) with C- and P-clothed subjects. The results showed that individual TSR had significant effects on not only Tcs but also on thermoregulatory responses during the Tcs decrease phase.

  • PDF

최근 40년(1979~2018) 우리나라 겨울 일 평균기온의 장기 변화 경향 및 주기 분석 (Long-term Trend and Period Analysis of Korean Daily Temperature During Winter Season of 40 Years (1979~2018))

  • 최지영;황승언;예상욱;송세용;김윤재
    • 대기
    • /
    • 제29권5호
    • /
    • pp.599-607
    • /
    • 2019
  • The change and periodicity of Korean winter temperature in the period 1979-2018 are investigated. It is shown that the winter temperature is on a long-term rise, with two regime shifts of winter temperature during 40 years. In addition, the decrease in cold days is confirmed along with the rise in temperature. Analysis of the periodicity of daily temperature in winter is carried out by means of power spectral analysis. Of the spectral peaks that are statistically significant, the most frequent detection exists on the time scale between 7 and 8 days. It is found that the number of significant periods have decreased since 2014, particularly no longer existent around the period of 7 day. The longer periods than 7 days gradually increase during 40 years, while the shorter periods show the tendency of decrease but recently rebound. Spectral analysis calculated from high/low-pass filtered daily temperature data also shows similar results.

외기온 변화에 따른 공기-공기/공기-물 형태로 된 복합형 열펌프 시스템의 성능 특성 분석 (Performance Analysis of Hybrid Heat Pump System of the Air-to-Air/Air-to-Water with the Ambient Temperature)

  • 송현갑
    • Journal of Biosystems Engineering
    • /
    • 제25권4호
    • /
    • pp.273-278
    • /
    • 2000
  • The hybrid heat pump system of the air to air and / or air to water was composed and its COP was analyzed with the ambient temperature on the opened and closed loop system respectively. The results be indicated by the equation(7) that the COP(Coefficient of Performance) of air-source(air to air and / or air-water) heat pump is effected with the ambient air temperature and AVACTHE.(Automatic Variable Area Capillary Type Heat Exchanger) 2. The COP of air-to-water heat pump without AVACTHE decreased in accordance with the ambient temperature decrease, however in case of the heat pump with AVACTHE the COP was maintained at 2.8∼3.0 level when the ambient temperature decrease from -$5^{\circ}C$ to $-11^{\circ}C$. 3. The COP of the air-to-water heat pump operated on the open loop was higher 40∼58% than that of the heat pump operated on the close loop. 4. The lower ambient temperature air effect on the COP of the air-to-air heat pump operated on the semi closed loop could be controlled using the AVACTHE, and at the high ambient air temperature the COP increased using the Bypass circuit.

  • PDF

Effects of Elevated $CO_2$ and Temperature on Competition between Rice and Echinochloa glabrescens Seedlings

  • Kim, Han-Yong
    • Plant Resources
    • /
    • 제1권1호
    • /
    • pp.43-48
    • /
    • 1998
  • The objective of this study was to determine how elevated $CO_2$ and temperature affected early growth and competition between direct seeded rice (Oryza sativa) and a common paddy weed (Echinochloa glabrascens). By using temperature gradient chambers. Rice and E. glabrescens were grown for 5 weeks at ratios of 1:0. 3:1 and 0:1 at three temperatures ($16.4^{\circ}C,\;19.8^{\circ}C,\;and\;22.2^{\circ}C$) and either in ambient (361ppm) or elevated (566ppm) $CO_2$. For both species. elevated $CO_2$ had no effect on mainstem leaf number while air temperature had a slight positive effect which was greater in E. glabrescens than rice. With elevated $CO_2$ rice leaf area index and plant height increased alightly in all species combinations but no increases were observed for E. Glabuescens. For rice in all combinations. elevated $CO_2$ tended to increase the rot and total biomass much more than any other growth parameters: the increases in root and total biomass resulting from elevated $CO_2$ ranged from 16% to 40%. depending on air temperature. At the lowest temperature, the decrease in rice biomass in combination with E. glabrescens was significantly greater at elevated $CO_2$ (18%) than ambient $CO_2$ (3%). At the highest temperature, however, the decrease in rice biomass at elevated $CO_2$ (22%) was less than that at ambient $CO_2$ (36%). The competitive ability of rice as measured by the decrease in biomass when grown in combination with E. glabrescens depended strongly on root growth and/or allocation. These results suggest that at higher temperatures elevated $CO_2$ could enhance the competitive ability of direct seeded rice during early growth. However, at lower temperatures. the competitive ability of E. glabrescens seems to be greater.

  • PDF

기상 관측자료 및 RCP 기후변화 시나리오를 고려한 용담댐 유입하천의 유량 및 수온변화 전망 (Assessment of Runoff and Water temperature variations under RCP Climate Change Scenario in Yongdam dam watershed, South Korea)

  • 이혜숙;김동섭;황만하;안광국
    • 한국물환경학회지
    • /
    • 제32권2호
    • /
    • pp.173-182
    • /
    • 2016
  • The objective of this study is to quantitatively analyze climate change effects by using statistical trends and a watershed model in the Yongdam dam watershed. The annual average air temperature was found to increase with statistical significance. In particular, greater increases were observed in autumn. Also, this study was performed to evaluate the potential climate change in the streamflow and water temperature using a watershed model (HSPF) with RCP climate change scenarios. The streamflow of Geum river showed a decrease of 5.1% and 0.2%, respectively, in the baseline data for the 2040s and 2080s. The seasonal impact of future climate change on the streamflow showed a decrease in the summer and an increase in the winter. The water temperature of Geum river showed an average increase of 0.7~1.0℃. Especially, the water temperature of Geum river showed an increase of 0.3~0.5℃ in the 2040s and 0.5~1.2℃ in the 2080s. The seasonal impact of future climate change on the water temperature showed an increase in winter and spring, with a decrease in summer. Therefore, it was determined that a statistical analysis-based meteorological and quantitative forecast of streamflow and water temperature using a watershed model is necessary to assess climate change impact and to establish plans for future water resource management.

3.5% NaCl 수용액의 온도변화가 복합조직강의 부식피로파괴에 미치는 영향 (The Effects of 3.5% NaCl Aqueous Solution Temperature on the Corrosion Fatigue Fracture of Dual phase steel)

  • 오세욱;도영문;박수영;김재철;김광영
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.140-147
    • /
    • 1992
  • Corrsion fatigue test was performed under rotated bending in 3.5% NaCl aqueous solution having a temperature from 278.deg.K in order to investigate the effects of aqueous solution remperature on the corrosion fatigue fracture of raw material steel(SS41) and dual phase steel that was produced from SS41 by a series of heat treatment. Corrosion fatigue life decreases remarkably with increase in solution temperature or with decrease in stress level. The corrosion fatigue life and the crack propagation rate at 303.deg.K show the similar behaviors with those at 318.deg.K, which is assumed to be caused by concentration polarization phenamena. The number and the lengths of microcracks increase with increase in solution temperature, so they lead to the decrease in corrosion fatigue life.

  • PDF