• Title/Summary/Keyword: Deck-plate slab

Search Result 73, Processing Time 0.031 seconds

A Study on Modifacation of a Prediction Equation for the Natural Frequency of a Composite Deck Floor System through the Simplification of a section Transformation (합성데크 플레이트 바닥구조의 단면환산 단순화를 통한 고유진동수 예측식의 보정에 관한 연구)

  • Im, Ji Hoon;Park, Jin Young;Hong, Won Kee;Kim, Hee Cheul
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.549-556
    • /
    • 2002
  • The natural frequency of a system is commonly used in evaluating the serviceability condition of a floor. However. the current equations recommended in many building codes do not consider the various material types of a slab system; thus. different results are observed. Likewise. the transformation of a slab section required to predict the natural frequency of a composite deck plate is complicated. due to the varying shapes of the deck plates. Therefore. a new and simplified method of transforming a composite slab into an equivalent concrete slab is proposed. he modified vibration prediction equation was proposed based on the current vibration prediction equation recommended by LRFD. Compared to other equations. it is the closest to those obtained from experiments. The modified equation provides about 14.3% more accurate results than that recommended by LRFD. Likewise. the applicability of the proposed equation to other types of composite deck plate floor system was validated.

An Experimental Study of the Composite Slab under a Repeated Loading (단조 반복하중이 작용하는 합성슬래브의 거동에 대한 실험적 연구)

  • Eom, Chul Hwan;Kim, Hee Cheul;Park, Jin Young;Seo, Sang Hoon
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.143-148
    • /
    • 2007
  • The application of metal deck floor system is increasing gradually and especially for office buildings. In the cases of large parking structures and storage structures, the construction period and the cost can be reduced. Also the steel deck system can prevent the crack of a floor and reduce the retrofit expenses. However, the floor should stand for the repeated truck load which is relatively heavier repeated loading. The mechanical behavior of a slab under repeated load is also different from the static loading state. An evaluation of a structural capacity was performed in this study through the dynamic capacity evaluation experiment for an application of a composite deck floor system as a parking structure slab. The period of repeated loadings were set up as 25years and 960,000 times monotone cyclic loads were applied at the center of the specimens. The tension crack propagation and patterns at the center of specimens were examined.

Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers (마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Hong, Geon-Ho;Kim, Gap-Deug;Choi, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • In the present study, to enhance the constructability, a composite slab system using deck plate and micro steel fiber concrete was studied. In the proposed slab system, on-situ re-bar placement is not required. Steel fibers replace the temperature reinforcement. The present study focused on the crack control at the slab top in the continuous composite slab without spliced bars. Eight continuous slabs with various parameters were tested under vertical loading. The test parameters were the amount and types of micro steel fibers, types of deck plate, and the use of top bars in the continuous slab. To evaluate the crack resistance of the slabs, crack widths were measured in the continuous slabs. The test results showed that although the top spliced bars were not used, cracking were restrained by large flexural stiffness of the composite sections.

Experimental Study on Bending and Shear Performance of Deck Type Void Slab with Trapezoidal Hollow Ball (사다리꼴 형상의 경량체를 가진 데크형 중공슬래브의 휨 및 전단성능에 대한 실험적 연구)

  • Kim, Pil Jung;Kim, Sang Mo;Park, Joon Hyuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.443-453
    • /
    • 2017
  • In this study, a trapezoidal hollow ball is used, instead of a spherical hollow ball commonly used in void slab, to secure the high hollow ratio in the deck type void slab. The bending and shear performance was measured with consideration for the shape change of the hollow ball. And to confirm the effect of deck plate and truss wire on shear performance, experiments were performed depending on the installation directions of the one-way deck plate. As a result, the bending performance of the deck type void slab with a trapezoidal hollow ball was similar to that of the void slab with a spherical hollow ball. However, according to the data of shear strength examined, the contribution of shear performance enhancement of the truss wire had a more effect on the shear performance of deck type void slab, rather than the influence by changing of the shape of hollow ball. In the previous studies, the shear strength is reduced to about 60%, due to the reduction of the effective section of concrete by installation of hollow ball. But in this experiment, the maximum load of specimen, in which the deck was installed in horizontal direction, so expected to have no influence on the shear performance, was only reduced to about 87%, due to the truss framework of truss wire.

Flexural Capacity and CO2 Reduction Evaluation for Composite Beam with Weight Reducing Steel Wire-Integrated Void Deck Plate slab (자중저감 철선일체형 중공 데크플레이트 슬래브를 사용한 합성보의 휨내력 및 CO2 감소량 평가)

  • Kim, Sang-Seop;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.313-323
    • /
    • 2012
  • The purpose of this study is to evaluate $CO_2$ reduction and the flexural performance of steel wire-integrated void deck plate slabs that were inserted in omega-shaped steel plates to reduce concrete and welded H-section beams. The void deck plate slab can secure the structure, not only reducing the weight of the building but it is also eco-friendly. Therefore, this study evaluated the flexural performance of the composite beam by conducting a monotonic loading test with the use of actuators. It quantitatively evaluated the $CO_2$ emission based on earlier studies. The main test parameters are the concrete thickness of upper slabs, and the interrupted width of the omega-shaped steel plate. The result of the test showed that the welded H-section beam applied steel wire-integrated void deck plate slabs that were inserted into the omega-shaped steel plate declined in flexural performance on the composite beam after reducing concrete volume. Likewise, it is effective in reducing $CO_2$.

Structural Performance of Super-Deck Plate Slab System with Truss Type Bar (트러스근을 사용한 슈퍼데크 플레이트의 구조성능평가)

  • Kim, Seong-Soo;Kim, Sang-Shik;Lee, Woo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.193-199
    • /
    • 2003
  • This paper presents the results of an experimental research project on 7 Super Deck Plates with continuous or simple beam types. The test parameters included the distance of truss, depth of deck plate and the type of beam. The test results are as follows ; When thickness of deck plate was increased, maximum strength was improved When the distance of truss bar was reduced from 20cm to 15cm, the mean value of maximum load was increased to 1.21 times. Continuous beam shown superior to simple beam, such as 5.03 times high strength, low deflection at yield point.

Structural Characteristics of Preloaded Deep Deck Composite Slabs with Tenns

  • Lee, Tae-Hun;Kyung, Jae-Hwan;Song, Jong-Wook;Choi, Sung-Mo
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.187-195
    • /
    • 2020
  • As deep decks are commonly used in construction fields and high-rise building. etc, the slim floor system is increasingly employed. But, the drawback of the slim floor system is that the use of 250 mm deep decks in a structure having a clear span of more than 6 m because of deflection and flexural buckling. This study suggests a non-support construction method where tendons are installed in the deep decks of the slim floor structure to introduce preload in order to control deflection in a structure having a clear span of 9 m. Loading tests were conducted to verify the composite effect and flexural capacity of the preloaded deep deck composite slab and evaluate the serviceability of the supportless construction method. The results showed the complete composite behavior of the preloaded deep deck composite slab with tendons. The specimens satisfied deflection limit and the working load was approximately 25% of the maximum load capacity. It is deemed that the cross-sectional area and yield strength of the deck plate should be taken into account in slab design and the yield strength and diameter of the tendon should be determined with the pre-tension taken into consideration.

A Study on the Structural Characteristic of Strengthened Bridge Deck Specimens Using External Bonded Plate (Plate로 전면보강된 교량 상판의 거동특성에 관한 연구)

  • 심종성;오홍섭;김언경
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.163-168
    • /
    • 2001
  • Punching shear in concrete slabs is a serious problem in certain structural systems, such as flat slab. In this study, mechanical improvement between specimens which are unstrengthened and strengthened with steel plate and fiber panel is experimentally investigated. The strengthened bridge deck specimens had increment of strength and broke down with punching shear failure. Strengthening ratio should be considered to restraint punching failure.

  • PDF

An Experimental Study on the Flexural Behavior of Composite Steel Deck Slab with Bored Openings (천공 개구부가 있는 합성슬래브의 휨거동에 관한 실험적 연구)

  • Eom, Chul Hwan;Kim, Hee Cheul;Park, Jin Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.607-614
    • /
    • 2006
  • The composite metal deck plate system has been widely used of late for office structures. However, composite floor decks are bored imprudently for installation in building equipment. In this study, experimental investigations of bored composite steel deck slabs were performed to evaluate the flexural capacity of each specimen. The variables set were the shapes and positions of the openings in the composite slabs. The results were analyzed in the form of load-displacement graphs and with respect to the ductility and energy dissipation capacity ofeach specimen to evaluate its structural capacity.

Structural Performance and Usability of Void Slab Established in T-deck Plate (T형 데크 플레이트 중공형 슬래브의 구조성능 및 사용성능)

  • Hong, Eun-Ae;Chung, Lan;Paik, In-Kwan;Yun, Sung-Ho;Cho, Seung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.677-684
    • /
    • 2012
  • In recent years, extension of life span of buildings is becoming an important issue in our society. To improve the life span of buildings, rhamen structure construction and long-spanned structures are advantageous. And in order to achieve this goal, structural elements of buildings must be light and slender. As an alternative method, general porous slabs are used frequently domestically and internationally. But the study on the porous slabs using T-deck plate and assembly of light weight precast construction is insufficient at present. In this study, flexural and fatigue tests were performed on six specimens to verify structural performance and serviceability. The main parameters of the specimens were light weight and T-deck plate construction possibility as well as slab thickness. The test results indicated that the strength of porous slabs using T-deck plate and assembly of light weight were much better than general RC slabs and porous slabs without T-deck plate. And stiffness was much better than that of other tested slabs.