• 제목/요약/키워드: Decay time

검색결과 894건 처리시간 0.028초

원자력발전소 고압전동기 모선 잔류전압 특성 (Motor Bus Residual Voltage Characteristics at Nuclear Power Plant)

  • 변상윤;김순용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.662_663
    • /
    • 2009
  • Motor bus transfer involves the process of transferring a bus that has several critical motors to an alternate source of power when the main normal power source feeding them is interrupted. Bus transfer is a time-critical application in which the transfer progress depends on various parameters such as the type of motor, load on the motor at the time of transfer, inertia of the motor, and the combined open-circuit time constant of various motors present on the bus at the time of transfer. This paper present the result of modeling and simulation of nuclear power motor bus using ETAP(Electrical Transient Analyzing Program) program for motor and motor bus residual voltage decay characteristics.

  • PDF

IPS-LCD에서의 표면액정배향효과가 시야각 특성과 응답속도에 미치는 영향 (Improvement of the response time and embodiment of the viewing angle in IPS mode)

  • 최재학;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.65-68
    • /
    • 1998
  • The mechanism of response time and viewing angle in in-plane switching ( IPS ) liquid crystal display ( LCD ) were investigated. The response time of photo-aligned IPS-LCD is fast compared with rubbing-aligned IPS-LCD on polyimide ( PI ) surface. The decay time $\tau$$\_$d/ is decreased with increasing the azimuthal anchoring energy A $\psi$ due to the steric interaction between the LC molecules and side chain of polymer. The viewing angle of IPS-LCD is increased by using photo-depolymerizatin method ; about ${\pm}$70$^{\circ}$at all direction.

  • PDF

Sensitivity Changes of Auxin Transport System in Maize Coleoptile Segments

  • 윤인선
    • Journal of Plant Biology
    • /
    • 제36권1호
    • /
    • pp.59-66
    • /
    • 1993
  • In maize coleoptile segments where auxin transport capacity decreases with time following excision, susceptability of the tissue to transport inhibitors such as N-1-naphthylphthalamic acid (NPA), 3,4,5-triiodobenzoic acid (TIBA) or high concentrations of IAA was found to be rather increased. A time-dependent increase in the sensitivity to NPA can be postulated since the dose-response curve for NPA was shifted in the‘aged’tissue to the left (i.e. lower concentration). Preincubation of the tissue at a low temperature abolished the time-dependent sensitivity change, suggesting that cellular metabolism could be involved. The NPA-sensitive state was also brought about by calcium depletion of the tissue, which can be partially reversed by addition of calcium. Presence of exogenous IAA in the preincubation medium kept the auxin transport system from decay, implicating auxin as an endogenous controlling factor. Results of our experiments indicate a reversible, time-dependent changes of auxin transport system in which transport capacity and sensitivity to NPA are tightly coupled. Changes in the sensitivity to NPA were also seen in auxin action as well.

  • PDF

Calculation of kinetic parameters βeff and L with modified open source Monte Carlo code OpenMC(TD)

  • Romero-Barrientos, J.;Dami, J.I. Marquez;Molina F.;Zambra, M.;Aguilera, P.;Lopez-Usquiano, F.;Parra, B.;Ruiz, A.
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.811-816
    • /
    • 2022
  • This work presents the methodology used to expand the capabilities of the Monte Carlo code OpenMC for the calculation of reactor kinetic parameters: effective delayed neutron fraction βeff and neutron generation time L. The modified code, OpenMC(Time-Dependent) or OpenMC(TD), was then used to calculate the effective delayed neutron fraction by using the prompt method, while the neutron generation time was estimated using the pulsed method, fitting Λ to the decay of the neutron population. OpenMC(TD) is intended to serve as an alternative for the estimation of kinetic parameters when licensed codes are not available. The results obtained are compared to experimental data and MCNP calculated values for 18 benchmark configurations.

Assessment of Bacteria Removal Using Silver Ion Absorbed Ceramic Filter

  • Kim, Woo-Hang;Smith, James
    • 한국환경과학회지
    • /
    • 제21권8호
    • /
    • pp.901-907
    • /
    • 2012
  • The objective of this study was to evaluate bacteria removal ability of the metallic silver which was baked silver ion impregnated ceramic filter at heating condition. Silver leaking from baked ceramic filter was tested to sustain bacteria removal for a long time. Silver impregnated ceramic filter could remove E. coli completely at $10^{12}$ MPN/100ml to $10^{13}$ MPN/100ml of influent. However, ceramic filter without silver did not remove E. coli completely under the same condition. After baking, the silver impregnated ceramic filter almost didn't leak out the silver ion from filter. Photo of TEM (Transmission Electron Microscopy) showed that absorbed silver ions remained in ceramic filter after baking process and most of silver were less than 10 nm. According to the increase in the amount of silver in the ceramic filter, removal efficiencies of E. coli were increased but turbidity removal was decreased. It can be accounted that increased removal efficiency of E. coli was from disinfection of silver that is in the ceramic filter. Simulated concentrations of bacteria agree well with the observed experimental effluent concentration data. Moreover, first-order decay coefficients increased to 0.0034/min after silver was added in the ceramic filter. Increase of first-order decay coefficient proves that silver-added ceramic filter can remove bacteria easily.

Accumulation and Decay of Macroscopic Correlations in Elementary Reactions Kinetics

  • Doktorov, Alexander B.;Kipriyanov, Alexander A.;Kipriyanov, Alexey A.
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.941-952
    • /
    • 2012
  • In the present contribution the Encounter Theory (ET) (the prototype of the classical Collision Theory in rarefied gases) concepts for widely occurring diffusion assisted irreversible bulk reactions A + A ${\rightarrow}$ C and A + B ${\rightarrow}$ C in liquid solutions examined by the authors in the literature are analyzed and compared with each other for these different types of reactions. It is shown that for a particular case of equal initial concentrations $[A]_0=[B]_0$ in the reaction A + B ${\rightarrow}$ C, when the kinetics of both reactions A + A ${\rightarrow}$ C and A + B ${\rightarrow}$ C in the framework of formal chemical kinetics and ET are the same, the accumulation of macroscopic correlations breaking the concepts of independent encounters and leading to the Generalized Encounter Theory (GET) are drastically different. The influence of the force interaction and the decay of nonstable reactants on the time behavior the macroscopic correlations is also briefly discussed.

레이저 형광여기법(LIF)를 이용한 복잡 난류유동장의 혼합특성에 관한 연구 (A Study on the Mixing Characteristics in Complex Turbulent Flow by a Laser Induced Fluorescence Method)

  • 김경천;정은호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.542-547
    • /
    • 2001
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera can be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration in each region after the dye infusion reflects the large scale mixing while the followed slow decay reveals the small scale mixing. The temporal change of concentration probability functions conjectures the two sequential processes in the batch type mixing. An inactive column of water existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

  • PDF

산화 이리듐의 물의 산화반응에 대한 버블 과전압 현상과 촉매 특성 연구 (Study on Electrocatalytic Water Oxidation Reaction by Iridium Oxide and Its Bubble Overpotential Effect)

  • 김정중;최용수;권성중
    • 전기화학회지
    • /
    • 제16권2호
    • /
    • pp.70-73
    • /
    • 2013
  • 산화 이리듐은 물의 산화반응에 대해 좋은 전기촉매 물질로서 많은 연구가 이루어 지고 있다. 최근 전기화학적 증폭방법을 이용하여 산화 이리듐 나노입자의 개별적인 촉매특성을 연구한 결과를 보면 촉매반응에 의한 전류가 지속적으로 유지되지 않고 시간에 따라 감소하는 결과가 얻어 졌다. 이러한 촉매특성의 사라짐에 대한 원인을 규명하고자 사이즈가 큰 이리듐전극을 산화시킨 산화이리듐 전극에서 물의 산화반응을 진행시켰다. 그 결과 나노입자에서와 유사하게 전류가 감소하는 현상이 관찰되었다. 큰 전극에서의 실험에서는 발생하는 산소방울을 관찰 할 수 있었는데 산소방울의 발생 주기가 전류의 증감주기와 일치하는 것으로 보아 전류의 감소는 산소방울에 의한 버블 과전압 때문으로 생각된다.

초고온가스로의 RCCS 해석을 위한 축대칭 모사 방법론 평가 (EVALUATION OF METHODOLOGY FOR AXISYMMETRIC SIMULATION OF RCCS IN VHTR)

  • 김성훈;조봉현;탁남일;김민환
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2010
  • RCCS is a passive safety-related system that removes the decay heat of VHTR when normal decay heat removal systems are in failure. Understanding thermo-hydraulics of RCCS is important to design a safer VHTR. RCCS consists of 292 cooling panels, which are placed in the reactor cavity. The layout of RCCS gives an idea that, for CFD simulations, cooling panels can be assumed to be one annulus tube. This assumption can reduce significantly the computational time, especially for the unsteady simulation. To simulate RCCS in an axisymmetric manner, three models were suggested and compared. Each model has (1) the same outer radius, (2) the same cross-sectional area (3) the same pressure drop, respectively, as the RCCS cooling panels. The steady-state simulation was conducted with these three models and the DO radiation model. It is found that over 90% of the heat from the outer wall of the reactor pressure vessel is transported to the RCCS by radiative heat transfer. The simulation with the third model, which has the same pressure drop as the design, estimates the closest wall temperature profiles to a thermo-hydraulic code, GAMMA+, result.

레이저 형광여기법(LIF)를 이용한 러쉬톤 터빈 교반기의 혼합특성에 관한 연구 (A Study on the Mixing Characteristics in a Rushton Turbine Reactor by a Laser Induced Fluorescence Method)

  • 정은호;김경천
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1145-1152
    • /
    • 2002
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields was obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera could be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter. height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration after the dye infusion reflects the large scale turbulent mixing while the fellowed slow decay reveals the small scale molecular mixing. The temporal change of concentration variance field conjectures the two sequential processes for the batch type mixing. An inactive column of water is existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.