• Title/Summary/Keyword: Decay Rate Method

Search Result 155, Processing Time 0.028 seconds

Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence (주택의 실내공기질 개선 평가 방법)

  • Yang, Won-Ho;Son, Bu-Soon;Yim, Sung-Kuk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.

A study of $Q_{Lg}^{-1}$ by the reversed two station method in the crust of central South Korea (Reversed Two Station Method (RSTM)에 의한 중부지방 $Q_{Lg}^{-1}$ 연구)

  • Cheong, Tae-Woong
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.3
    • /
    • pp.211-218
    • /
    • 2002
  • The reversed two station method (RSTM) devised by Chun et al. (1987) is widely used to obtain $Q_{Lg}^{-1}$ for Lg wave data with hypocentral distance greater than 90 km. By applying RSTM to the Lg data of central South Korea with hypocentral distance between 95 and 381 km, we obtained high $Q_{Lg}^{-1}$. The value of $Q_{Lg}^{-1}$ is very similar with that of southeastern S. Korea, which is derived from the same method for similar distances. The studied hypocentral range seems to distort $Q_{Lg}^{-1}$ to high value because decay rate in this range is higher than 0.5, which is typical decay rate of surface wave.

  • PDF

Prediction of Concentration Decay of Volatile Organic Compounds from Ondol Floor and Furniture (주택에 설치한 온돌 마루 및 붙박이 가구에서 발생하는 휘발성유기화합물의 농도 감소 예측)

  • Cho, Hyun;Pang, Seung-Ki;Baik, Yong-Kyu;Sohn, Jang-Yeul
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.51-57
    • /
    • 2005
  • In this study, time-dependent concentration variations of VOCs from fixed furniture and Ondol floor widely used as finishing material of the floor were measured, and prediction equations were developed based on the measured results. VOCs were measured and analyzed based on EPA TO-17 and NIOSH 1500, 1501 method respectively, and GC/FID were used for the analysis of VOCs concentration. Measurements were carried out for 10 days after the installation of furniture and for 40 days after the installation of the floor in the residence constructed more than 10 years ago. In both case of floor and furniture installation, time-dependent concentration decay of VOCs can be properly converted into logarithmic scale. Especially in case of furniture, toluene showed the highest concentration and took longest time to decay. As a result of the prediction of VOCs concentration decay under different air change rate using estimated equations, concentration decay rate of indoor VOCs increased rapidly as the air change rate also increased.

Decay and diffusion characteristic of electron and ion surface charges on MgO

  • Syn, Ho-Jung;Jeong, Dong-Cheol;Lee, Tae-Ho;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.377-380
    • /
    • 2008
  • In this work, we measured the spatiotemporal surface charge distribution by the longitudinal electro-optic amplitude modulation method with BSO single crystal to investigate the decay and diffusion characteristics of surface charges in three types of MgO. The speed of decay and diffusion of two different kinds doped MgO is compared with those of pure MgO. The difference in the characteristics of the decay and diffusion between the electron and ion surface charges is investigated separately. We found that the rate of ion decay is the major factor that makes the difference of the temporal variation of wall voltage among different types doped MgO.

  • PDF

New Fashion Clothing Image Classification (새로운 패션 의류 이미지 분류)

  • Shin, Seong-Yoon;Lee Hyun-Chang;Shin, Kwang-Seong;Kim, Hyung-Jin;Lee, Jae-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.555-556
    • /
    • 2021
  • We propose a novel method based on a deep learning model with an optimized dynamic decay learning rate and improved model structure to achieve fast and accurate classification of fashion clothing images.

  • PDF

Experimental Methods for the Measurement of Damping Loss Factors (내부손실계수 측정을 위한 실험 방법)

  • 김관주;최승권
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1187-1192
    • /
    • 1999
  • The purpose of this study is to determine the most appropriate experimental method of the measurement of "damping loss factors" (DLF) for the statistical energy analysis(SEA) calculation. The successful prediction of vibration levels from the structure is critically dependent on the accurate estimation of DLF's not only in conventional vibration analysis but especially in SEA. Unforunately, calculation of accurate DLF is not an easy matter. So experimental methods are made use of for the DLF values. Three kinds of experimental methods for estimating DLF, i.e. decay rate method, half-power bandwidth method and power balance method, are presented and tests are carried out for the plate and the cylindrical shell examples. Pro and con of each methods is reviewed. Finally, calculated DLF values are used for vibration level estimation using commercial SEA software and compared with measured vibration data.tion data.

  • PDF

Predictive Equations of Ground Motions in Korea

  • Noh, Myung-Hyun
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.3
    • /
    • pp.171-179
    • /
    • 2006
  • Predictive equations of ground motions are one of the most important factors in the seismic hazard analysis. Unfortunately, studies on predictive equations of ground motions in Korea had been hampered due to the lack of seismic data. To overcome the lack of data, seismologists adopted the stochastic method based on the seismological model. Korean predictive equations developed by the stochastic method show large differences in their predictions. It was turned out through the analysis of the existing studies that the main sources of the differences are the uncertainties in the (Brune) stress drop and spectral decay rate . Therefore, it is necessary to focus the future research on the reduction of the uncertainties in the two parameters.

  • PDF

Waves propagating in railway tracks at high frequencies (철로를 따라 장거리 전파하는 고주파수 대역 파동 특성 연구)

  • Ryue, J.;Thompson, D.J.;White, P.R.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.791-796
    • /
    • 2011
  • In order to understand long range wave propagation in railway tracks, it is required to identify how far vibrations can travel along a rail. To answer this question, the attenuation characteristics of the main propagating waves are required as a function of distance. In this work, it is identified which wave types predominantly propagate on various regions of the rail cross-section. Then decay rates of propagating waves in railway tracks are investigated for frequencies up to 80 kHz. A numerical method called the Wavenumber Finite Element (WFE) method is utilized to predict dispersion curves and decay rates for a rail on a continuous foundation. In order to validate the simulated results, measurements have been performed on a test track and an operational railway track. The measured results are compared with the output of the simulations and good agreements are found between them.

  • PDF

Estimation of Mean Air Exchange Rate and Generation Rate of Nitrogen Dioxide Using Box Model in Residence (주택에서 Box Model을 이용한 평균 환기율 및 이산화질소 발생량 추정)

  • Bae, Hyeon Ju;Yang, Won Ho;Son, Bu Sun;Kim, Dae Won
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.645-653
    • /
    • 2004
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate these factors by application of multiple measurements. For the total duration of 30 days, daily indoor and outdoor $NO_2$ concentrations were measured in 30 houses in Brisbane, Australia, and for 21 days in 40 houses in Seoul, Korea, respectively. Using a box model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated, Sub-sequently, the ventilation and source strength were estimated. In Brisbane, the penetration factors were $0.59\pm0.14$ and they were unaffected by the presence of a gas range. During sampling period, geometric mean of natural ventilation was estimated to be $l.l0\pm1.5l$ ACH, assuming a residential $NO_2$ decay rate of 0.8 hr^{-1}$ in Brisbane. In Seoul, natural ventilation was $1.15\pm1.73$ ACH with residential $NO_2$ decay rate of 0.94 hr^{-1}$ Source strength of $NO_2$ in the houses with gas range $(12.7\pm9.8$ ppb/hr) were significantly higher than those in houses with an electric range $(2.8\pm2,6$ ppb/hr) in Brisbane. In Seoul, source strength in the houses with gas range were $l6.8\pm8.2$ ppb/hr. Conclusively, indoor air quality using box model by mass balance was effectively characterized.

Decay Rate and Changes of Nutrients during the Decomposition of Zizania latifolia

  • Mun, Hyeong-Tae;Jeong, Namgung;Kim, Jeong-Hee
    • The Korean Journal of Ecology
    • /
    • v.24 no.2
    • /
    • pp.81-85
    • /
    • 2001
  • Decomposition of Zizania latifolia was investigated with litterbag method for 13 months from November in 1998 to December in 1999, at the fringe of stream at Boryeong, Chungnam Province in Korea. After 13 months, remaining mass of leaves, culms and rhizomes was 16.9, 14.7, and 10.1%, respectively. Mass loss of the rhizomes was higher than those of the leaves and culms. The decay rate of leaves, culms and rhizomes was 1.86, 2.00 and 2.36 per year, respectively. Initial concentration of N, P, K, Ca, and Mg of leaves, culms and rhizomes was 18.0, 14.5, 44.0 mg/g for N,0.18, 0.12, 0.67 mg/g for P, 14.1 ,14.2, 14.8 mg/g for K,3.6, 1.5, 0.3 mg/g for Ca, 1.1, 0.5, 0.5 mg/g for Mg, respectively. Concentrations of N and P in rhizomes were higher than those in leaves and culms. Except for Mg in rhizomes, there was no immobilization period during the decomposition. Most of the N, P and Mg were lost during the first 3 months. In case of K and Ca, most were lost within 1 month.

  • PDF