• Title/Summary/Keyword: Dead-end mode

Search Result 21, Processing Time 0.027 seconds

Dead-end Mode Operation of a Large Scale PEM Fuel Cell Stack (대면적 고분자전해질 연료전지의 데드엔드 운전)

  • Jeong, Jeehoon;Shin, Hyunkhil;Han, In-Su;Seo, Hakyu;Kim, Minsung;Cho, Sungbaek;Hur, Taeuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.83.1-83.1
    • /
    • 2010
  • A Dead-end mode operation is one of the best way to maximize the gas usage rate. But, some components of fuel cell stack like gas diffusion layer(GDL) or membrane can be damaged in dead-end mode operation. In this study, a Large Scale Polymer electrolyte membrane fuel cell(PEMFC) for a dead-end operation has been developed. The stack is composed with 4 cells which has over 400cm2 of active area. Hydrogen is used as a fuel, and oxygen is used as a oxidant. The dead-end operation performance was evaluated by a long-term dead-end mode operation. The fuel cell stack is operated over 1,500 hours in dead-end mode operating fuel cell test station. And the performance change of the fuel cell stack was investigated.

  • PDF

A study on the characteristic of the anodic dead-end mode PEM fuelcell and performance improvement by pulsation effect (수소 데드 앤드 연료전지의 특성 및 맥동을 이용한 성능 향상에 관한 실험적 연구)

  • Choi, Jong-Won;Hwang, Yong-Sheen;Kim, Sung-Il;Ha, Jeong-Hoon;Park, Joon-Ho;Cha, Suk-Won;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.336-340
    • /
    • 2009
  • This paper presents experimental results carried out on the purge characteristic of the anodic dead-end mode fuelcell and how to improve the cell performance by pulsation effects. The dead-end mode fuelcell has some merits that a fuel supplying device is not needed and the cell power is higher than that in the open mode fuelcell. However, the purge is necessary for preventing the porous media from being flooded by liquid water formed in the channel. At this time, the un-reacted fuel is discharged with the liquid water together in purge process. The discharged fuel can make the fuel efficiency lower. Therefore, the number of purge times should be decreased for the better fuel efficiency. In this study, the outlet of the anode channel was equipped with a purge solenoid valve and a pulsation generator. The purge times was decreased when the current density decreased and operation pressure increased without the pulsation effects. In addition, when the pulsation effects such as various frequencies or amplitudes were applied, purge times was alleviated up to 40%.

  • PDF

An experimental study on the performance improvement of dead-end type PEMFC with pulsating effect (맥동 효과를 이용한 dead-end type 연료전지의 성능향상에 대한 실험적 연구)

  • Choi, Jong-Won;Seo, Jeong-Hoon;Hwang, Yong-Sheen;Lee, Dae-Heung;Cha, Suk-Won;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.567-571
    • /
    • 2008
  • PEM Fuel Cell operation mode can be classified into dead-end mode or open mode by whether the outlet port is blocked or not. Generally, dead-end type fuel cell has some merits on the pressure drop and system efficiency because it can generate more power than the open type fuel cell due to high operating pressure condition. However, the periodic purging process should be done for removing water which is formed as product of a reaction in the gas diffusion layer. In this study, cathode side dead-end type operation has been conducted. Moreover, pulsating flow generator at the outlet of cathode side has been suggested for increasing the period to purge the formed water because the pulsating flow can make formed water scattered uniformly over the whole channel. As a result, the purging period with pulsation increased by 1.5-2 times longer than that without pulsating.

  • PDF

Small Hydrogen Regulator for Mobile Fuel Cells (모바일 연료전지용 초소형 수소 레귤레이터)

  • Kim, Hyung-Jin;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.129-132
    • /
    • 2011
  • This paper presents small hydrogen regulator for the mobile fuel cell. Mobile fuel cell is generally classified into open-end type and dead-end type. In the open-end type, flow rate of hydrogen is constantly controlled, while pressure of hydrogen is constantly maintained in the dead-end type. Considering the efficiency and stability of the fuel usage, dead-end type is more suitable with mobile fuel cell. Mobile fuel cell operated by dead-end mode requires hydrogen regulator which controls the hydrogen pressure from 0.1bar to 0.5bar within 3% error. In this paper, small hydrogen regulator (volume of 2.6cc) was fabricated by stainless steel. Regulation characteristics was experimentally evaluated.

A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode (역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구)

  • Eom, Jung Yeol;Kim, Kwan Yeop;Kim, Young Hoon;Song, June Sup;Kim, Hyung Soo;Han, Myung Ae;Yang, Hyung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

Performance Characteristics of a Polymer Electrolyte Fuel Cell with the Anodic Supply Mode (고분자 전해질 연료전지의 수소극 공급모드에 따른 성능특성)

  • Lee, Yong-Taek;Park, Cha-Sik;Heo, Jae-Hyeok;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.588-595
    • /
    • 2007
  • The water transport inside a polymer electrolyte fuel cell (PEFC) varied according to the anodic supply mode. The performance characteristics of a PEFC which can be affected by the water transport were observed with the anodic supply mode. In the flow-through and recirculation mode the performance showed no reduction with time because the flow in the anode was not stagnated. In the dead-end mode, without any discharged gas, the water remains inside of the anode, which caused the reduction of the performance with the lapse of time. However, even in the dead-end mode, little reduction of the performance with time was shown when only the anode was humidified externally. It means that the back-diffusion was the major factor to the accumulation of water in the anode rather than external humidification.

Free Vibrations of Beams with Static Deflections due to Dead Loads (사하중에 의한 정적 처짐을 고려한 보의 자유진동)

  • 이병구;박광규;오상진;모정만
    • Journal of KSNVE
    • /
    • v.4 no.4
    • /
    • pp.451-457
    • /
    • 1994
  • A numerical method is presented to obtain natural frequencies and mode shapes of uniform elastic beams with static deflections due to dead loads. The differential equation governing the free vibration of beam taken into account the static deflection due to deal loads is derived and solved numerically. The hinged-hinged, clamped-clamped and clamped-hinged end constraints are applied in the numerical examples. As the numerical results, the lowest three nondimensional frequency parameters are reported as functions of nondimensional system parameters; the load parameters, and the slenderness rations. And some typical mode shapes of free vibrations are also presented in figures.

  • PDF

Implementation of an Auto-Steering System for Recreational Marine Crafts Using Android Platform and NMEA Network

  • Beirami, Mohammadamin;Lee, Hee Yong;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.577-585
    • /
    • 2015
  • This paper deals with development of an autopilot system for leisure yacht based on NMEA 2000 network and android platform. The developed system can operate both for manual steering and automatic navigation mode. In automatic steering mode, after manipulation of commands which are NMEA 0183 sentences by android platform, the developed system translates and sends the packets through NMEA 2000 network. Then the controller which is connected to NMEA 2000 network receives the commands and controls the boat's rudder system automatically. The automatic steering mode is achieved by cooperation of two controllers; one for controlling the rudder system, and the other for controlling the vessel's heading. To control the vessel's rudder and heading angle two PID controllers are developed with an adjustable dead-band gain. Also, in order to eliminate the steady-state error occurred by applying dead-band, an integral controller which specifically supervises the system's behavior inside the dead-band area is developed. In this paper, at the first stage, simulations are accomplished using computer in order to examine the feasibility of the proposed based on simulation results. In the next step, the system on a real hydraulic steering model is implemented and at the end the performance examination by implementing it on a real boat and doing test navigation is executed.

Experimental Analysis for Optimization of PEM Fuel Cell Dead-end Operation (고분자전해질 연료전지 Dead-end 운전 최적화에 대한 실험적인 연구)

  • Lee, Bonggu;Sohn, Young-Jun
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.2
    • /
    • pp.136-147
    • /
    • 2015
  • Dead-ended operation of Proton Exchange Membrane Fuel Cell(PEMFC) provides the simplification of fuel cell systems to reduce fuel consumption and weight of fuel cell. However, the water accumulation within the channel prohibits a uniform supply of fuel. Optimization of the purge strategy is required to increase the fuel cell efficiency since fuel and water are removed during the purge process. In this study, we investigated the average voltage output which depends on two interrelated conditions, namely, the supply gas pressure, purging valve open time. In addition, flow visualization was performed to better understand the water build-up on the anode side and cathode side of PEMFC in terms of a variety of the current density. We analyzed the correlation between the purge condition and water flooding.

Experimental Study of Performance of PEMFC Operated in Dead-End Mode (수소극 Dead-End 모드 고분자 전해질 연료전지의 실험적 연구)

  • Ji, Sang-Hoon;Hwang, Yong-Sheen;Choi, Jong-Won;Lee, Dae-Young;Park, Joon-Ho;Jang, Jae-Hyuk;Kim, Min-Soo;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.643-648
    • /
    • 2010
  • Portable fuel cells are commonly operated in the dead-end mode because of such as high fuel utilization. However, the performance of such systems deteriorates continuously with an increase in the amount of by-products such as water vapor and nitrogen. In this study, to verify the effect of water vapor on Proton Exchange Membrane Fuel Cells (PEMFCs), constant-load experiments were carried out for a current density of 600 mA/cm2 and a voltage of 0.4 V, respectively. The performance of the cell was more stable under constant voltage conditions than under constant current density conditions. Condensed water accumulated in the anode channel near the cell outlet. The experimental results show how the relative humidity (RH = 0.15, 0.4 and 0.75) of air at the cathode side affect the performance of PEMFCs with dead-end anode. At RH values higher than 0.15, the mean power density increased by up to 51% and the mean purge duration decreased by up to 25% compared to the corresponding initial values.