• Title/Summary/Keyword: Dead Volume

Search Result 134, Processing Time 0.024 seconds

Morphological Assessment of Proximal Restoration Depending on Different Matrix Systems in Primary Molars with a 3D Scanner: In Vitro Studies (매트릭스 시스템에 따른 유구치 인접면 수복물에 대한 3D 스캐너를 이용한 형태학적 평가: 실험실적 연구)

  • Hyewon Shin;Nanyoung Lee;Joohun Song;JoonSeong Kim;Myeongkwan Jih
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.4
    • /
    • pp.396-408
    • /
    • 2023
  • The purpose of this study was to compare the proximal surface contour, size of contact area, and volume difference before and after restoration in artificial teeth of primary molars during proximal composite resin restoration using different matrix systems. Four types of artificial teeth were restored with composite resin using sectional matrix systems-Palodent V3 Sectional Matrix System and myJunior Kitand a circumferential matrix system-Tofflemire Matrix System-and modeled threedimensionally for analysis. When sectional matrix systems were used, there was a higher probability of concave proximal surface contour and simultaneously greater contact area and volume. This is attributed to the dead soft properties of the matrix band used in sectional matrix systems, which can lead to deformation of the band and hence an excessive amount of resin applied around the contact point. Additionally, the rubber wedge in the sectional matrix system may not help the matrix band fit into the cavity. Therefore, based on the findings of this study, morphological aspects need to be carefully considered for proximal composite resin restoration of primary molars using sectional matrix systems.

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

Comparison of stand structure and growth characteristics between Korean white pine plantation and oak-dominated natural deciduous forest by thinning treatment

  • Lee, Daesung;Choi, Jungkee
    • Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.85-98
    • /
    • 2022
  • Background: Korean white pine (Pinus koraiensis) is a major commercial species, and the importance of the oak trees (Quercus spp.) is increasing due to various factors such as environmental and ecological values. However, more information is required to clearly understand the growth characteristics of these species especially regarding thinning intensity. This study was performed to provide the basic information to develop the silvicultural guideline and field manual by analyzing tree and stand characteristics in line with thinning intensity in the Korean white pine plantation and oak-dominated natural deciduous forest. Results: Diameter at breast height (DBH) and volume changes by the thinning intensity in the Korean white pine plantation were significantly different from those in the oak-dominated deciduous natural forest. In particular, DBH distribution in the pine stand appeared that there were more large diameter trees as the thinning intensity was higher. DBH periodic annual increment (PAI) of the pine stand was higher as the thinning intensity was stronger and the growth period was shorter. This trend was similarly shown in the natural deciduous forest, but the amount of PAI was smaller than in pine stand. The volume PAI after thinning was not decreased over time. In each stand type, the PAI tended to be lower as stand density was higher. The volume PAI in the pine stand was significantly higher than that in the oak-dominated natural deciduous forest. Dead trees occurred the most in the unthinned plots of each stand type, and those were higher in the natural deciduous forest. Ingrowth trees were observed only in the natural deciduous forest, and its distribution was the lowest in unthinned plots; Korean white pine as ingrowth occurred the most frequently among many tree species. Conclusions: Different effects of thinning treatment on DBH and volume PAI, mortality, and ingrowth were observed for each stand. With respect to forest growth, Korean white pine plantation was superior to the oak-dominated natural deciduous forest. The results of this study offer fundamental information for the development of silvicultural guidelines for Korean white pine plantations and oak-dominated natural deciduous forests in Korea.

Factors influencing the prognosis after total correction of tetralogy of Fallot (Fallot 4징증의 근치수술후 예후에 영향을 미치는 요소)

  • Min, Yong-Il;O, Bong-Seok;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.71-80
    • /
    • 1987
  • Twenty six patients were operated a total correction of tetralogy of Fallot between Jan., 1984 and July, 1985 at the Dept. of thoracic and cardiovascular surgery, Chonnam University Medical School, and a comparison between the survived group [n = 18] and the dead group [n = B was performed to detect factors influencing laboratory data, cineangiographic findings, operative findings and methods, and pump time. Following results were obtained, 1. There was no significant difference between two groups in the preoperative P.O2 and hematocrit level. 2. The size of the interventricular defect was not related to the operative mortality. 3. There was a significant difference in mortality rate between combined type of stenosis of pulmonary artery, valve and infundibulum and other types of right ventricular outflow tract stenosis. 4. There was a significant difference in mortality rate between the transannular patch reconstruction and other types of operative procedure. 5. There was no significant difference between two groups in total bypass time and aortic time. 6. There was no significant difference between two groups in left ventricular end diastolic volume and right ventricular end diastolic volume. 7. The operative mortality was related to the ratio of the diameter of the pulmonary valve annulus or each pulmonary artery to the ascending or descending aorta in cineangiographic findings, but there was no statistical significance of which probably is due to the lack of the total number of patients.

  • PDF

Effect of Multiple Showering and Vitamin Supplementation on Sexual Behaviour, Quality and Freezability of Buffalo Bull Semen

  • Singh, Pawan;Sengupta, B.P.;Tripathi, V.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.184-188
    • /
    • 2001
  • In a summer study during May to July, involving 12 young Murrah buffalo bulls at forty months of average age, the effects of multiple shower vs single shower body cooling and vitamin A, D and E supplementation on the sexual behaviour, semen quality and freezability were investigated. The animals were divided into two groups (6 animals in each group) and housed in a half-walled shed with proper spacing, the feeding management being identical. The bulls in the control group were given a single shower at 1000 h, whereas the experimental bulls were given four showers at 10,12,14 and 16 h. In addition, the experimental bulls were given vitamin A, D and E injections at fifteen day intervals. The sexual behaviour of bulls was observed in terms of reaction time, sexual aggressiveness and ejaculatory thrust. Semen quality of all the bulls was assessed in terms of volume, mass activity, live-dead sperm and sperm concentration, sperm motility and morphology, and acrosomal abnormality. The sexual behaviour did not vary significantly between the groups, whereas semen quality differed significantly for volume, per cent live sperms, total sperms per ejaculate and total live sperm per ejaculate between groups. It can be concluded that sexual behaviour was not influenced by the thermal comfort treatment coupled with periodic vitamin A, D and E injections. But the treatments improved most of the seminal traits in the experimental group of bulls. However, benefit of treatment was not reflected in the freezability traits of the semen.

The effect of front edge on efficiency for point and volume source geometries in p-type HPGe detectors

  • Esra Uyar ;Mustafa Hicabi Bolukdemir
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4220-4225
    • /
    • 2022
  • Monte Carlo (MC) simulations are increasingly being used as an alternative or supplement to the gamma spectrometric method in determining the full energy peak efficiency (FEPE) necessary for radionuclide identification and quantification. The MC method is more advantageous than the experimental method in terms of both cost and time. Experimental calibration with standard sources is difficult, especially for specimens with unusually shaped geometries. However, with MC, efficiency values can be obtained by modeling the geometry as desired without using any calibration source. Modeling the detector with the correct parameters is critical in the MC method. These parameters given to the user by the manufacturer are especially the dimensions of the crystal and its front edge, the thickness of the dead layer, dimensions, and materials of the detector components. This study aimed to investigate the effect of the front edge geometry of the detector crystal on efficiency, so the effect of rounded and sharp modeled front edges on the FEPE was investigated for <300 keV with three different HPGe detectors in point and volume source geometries using PHITS MC code. All results showed that the crystal should be modeled as a rounded edge, especially for gamma-ray energies below 100 keV.

A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS (ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화)

  • Woo, B.C.;Han, S.W.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

Flow Simulation of a Small Engine Carburettor (소형엔진 기화기의 유동해석)

  • Bae, Bong-Ki;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.511-514
    • /
    • 2009
  • 현재 일반적으로 사용되는 300cc 소형엔진 기화기의 최적화 및 성능 향상을 위하여 유동해석을 수행하였다. 베르누이의 정리를 기본으로, 성능을 발휘하는 주요 설계인자인 기화기 내부의 벤튜리 튜브의 각도, 길이 등을 변수로 하여 유동해석을 수행하였다. 그 결과를 분석하여 최적화된 모델을 제시하였다. 결론적으로, 유동 해석을 바탕으로 기존 사양 대비 향상된 성능의 모델을 제시하였다. 유동해석을 통해 기화기 내부의 벤튜리관에 곡면(Rounding)처리를 적용함으로 기화기에서 소모되는 흡기저항을 줄여 펌핑로스를 저감활수 있음을 확인하였다. 펌핑로스의 저감은 엔진 연비의 향상과 엔진토크에 긍정적 효과로 작용할 것으로 기대된다. 벤튜리관의 출구 각도를 감소시킴으로 박리를 개선하여 Dead Volume을 줄임으로서 기존 모델에 대비하여 원활해진 유동의 흐름을 얻을 수 있었다. 이는 흡기유량을 증대시키고 엔진출력을 상승시키는 효과로 작용할 것으로 예상된다.

  • PDF

A Study on the output ripple reduction of Active-Clamp Forward Converter (액티브 클램프 포워드 컨버터의 출력 리플 저감에 관한 연구)

  • Jung, Jae-Yeop;Kim, Yong;Bae, Jin-Yong;Kwon, Soon-Do;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.963_964
    • /
    • 2009
  • This paper presents an output ripple reduction of Active-Clamp Forward Converter, which is mainly composed of interleaving two active-clamping forward converters. By interleaving, Output ripple is reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve ZVS during the dead times. The duty cycles are not limited to be equal and within 50%. The complementary switching and the resulted interleaved output inductor currents diminish the current ripple in output capacitors. Accordingly, the smaller output chokes and capacitors lower the converter volume and increase the power density. Detailed analysis of this ouput reduction of Active-Clamp Forward Converter is described.

  • PDF

Fabricationof small size catridge for electrolyte measurement including flow-channel and microsensors (Flow-channel과 microsensor를 내장한 전해질 측정용 소형 카트리지 제작)

  • 이영철;조병욱;김창수;고광락;손병기
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.78-83
    • /
    • 1998
  • A small size cartrideg for FET type electrolyte sensor is designed and faricated with much simplified process by using micromachining tenchiques such as silicon etching andglass bonding. Size of the whole cartideg is 2.4cm*2.5cm, and the dead volume of a micro flow-channel in the cartrideg is only 8.5.mu.l. The photosensitive polymer(THB 30) is used to define a micropool and to encapsulate the sensor surface for standardizationof electrolyte sensors. To miniaturize micro flow-channel conventional reference electrode(Ag/AgCl) a differential amplification is introduced using REFET and quasi reference electrode. Refet was fabricated using photosensitive polymer(OMR 83). The fabricated cartridge with built-in pH-ISFET showed good operational characteristics such as linearity and high sensitivity (55.4mV/pH) in a wide pH range(pH2-pH12).

  • PDF