• Title/Summary/Keyword: Dead Space

Search Result 280, Processing Time 0.031 seconds

Extensive calcific myonecrosis of the lower leg treated with free tissue transfer

  • Kim, Tae Gon;Sakong, Yong;Kim, Il Kug
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.329-332
    • /
    • 2021
  • Calcific myonecrosis is a rare condition in which hypoperfusion due to compartment syndrome causes soft tissue and muscle to become calcified. As calcific myonecrosis gradually deteriorates, secretions steadily accumulate inside the affected area, forming a cavity that is vulnerable to infection. Most such cases progress to chronic wounds that are unlikely to heal spontaneously. After removing the calcified tissue, the wound can be treated by primary closure, flap coverage, or a skin graft. In this case, a 72-year-old man had extensive calcific myonecrosis on his left lower leg, and experienced swelling and increasing tenderness. After removing the muscle calcification, we combined two anterolateral thigh free flaps, which were harvested from the patient's right and left thigh, respectively, to reconstruct the wound with a dead-space filler and skin-defect cover at the same time. The patient recovered without revision surgery or major complications.

Temporomandibular joint re-ankylosis: a case report and literature review

  • Flora Kalita;Arunkumar KV
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.4
    • /
    • pp.218-222
    • /
    • 2023
  • Re-ankylosis is a common postoperative complication of temporomandibular joint (TMJ) ankylosis surgery. Various surgical options to prevent re-ankylosis, both with and without interpositional material, have been discussed in the literature. However, no standardized protocol has been suggested for management or prevention of TMJ ankylosis. This paper discusses the probable causes behind TMJ re-ankylosis and presents a case of unilateral TMJ re-ankylosis, which was managed by gap arthroplasty using an autologous abdominal dermal fat graft as an interpositional material and closely monitored for signs of relapse. Autologous fat graft acted as an effective barrier between the glenoid fossa and mandibular condyle, thus preventing dead space, hematoma and heterotrophic bone formation. A brief review of the literature and update on TMJ re-ankylosis are also presented.

INNOVATIVE CONCEPT FOR AN ULTRA-SMALL NUCLEAR THERMAL ROCKET UTILIZING A NEW MODERATED REACTOR

  • NAM, SEUNG HYUN;VENNERI, PAOLO;KIM, YONGHEE;LEE, JEONG IK;CHANG, SOON HEUNG;JEONG, YONG HOON
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.678-699
    • /
    • 2015
  • Although the harsh space environment imposes many severe challenges to space pioneers, space exploration is a realistic and profitable goal for long-term humanity survival. One of the viable and promising options to overcome the harsh environment of space is nuclear propulsion. Particularly, the Nuclear Thermal Rocket (NTR) is a leading candidate for nearterm human missions to Mars and beyond due to its relatively high thrust and efficiency. Traditional NTR designs use typically high power reactors with fast or epithermal neutron spectrums to simplify core design and to maximize thrust. In parallel there are a series of new NTR designs with lower thrust and higher efficiency, designed to enhance mission versatility and safety through the use of redundant engines (when used in a clustered engine arrangement) for future commercialization. This paper proposes a new NTR design of the second design philosophy, Korea Advanced NUclear Thermal Engine Rocket (KANUTER), for future space applications. The KANUTER consists of an Extremely High Temperature Gas cooled Reactor (EHTGR) utilizing hydrogen propellant, a propulsion system, and an optional electricity generation system to provide propulsion as well as electricity generation. The innovatively small engine has the characteristics of high efficiency, being compact and lightweight, and bimodal capability. The notable characteristics result from the moderated EHTGR design, uniquely utilizing the integrated fuel element with an ultra heat-resistant carbide fuel, an efficient metal hydride moderator, protectively cooling channels and an individual pressure tube in an all-in-one package. The EHTGR can be bimodally operated in a propulsion mode of $100MW_{th}$ and an electricity generation mode of $100MW_{th}$, equipped with a dynamic energy conversion system. To investigate the design features of the new reactor and to estimate referential engine performance, a preliminary design study in terms of neutronics and thermohydraulics was carried out. The result indicates that the innovative design has great potential for high propellant efficiency and thrust-to-weight of engine ratio, compared with the existing NTR designs. However, the build-up of fission products in fuel has a significant impact on the bimodal operation of the moderated reactor such as xenon-induced dead time. This issue can be overcome by building in excess reactivity and control margin for the reactor design.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

The Effectiveness of Progressive Tension Suture at Latissimus Dorsi Muscle Harvest (광배근 근피판 거상 후 점진적 긴장 봉합술의 유용성)

  • Moon, Joo Bong;Park, Jung Min;Kwon, Yong Seok;Lee, Keun Cheol;Kim, Seok Kwun;Cho, Se Heon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.611-616
    • /
    • 2007
  • Purpose: The latissimus dorsi muscle flap is a versatile flap used in a variety of reconstructive procedures. The most common complication of LD muscle flap is donor site seroma, reported to occur in 20 to 79 percent of cases. The formation of dead space under the flap is intimately associated with seroma formation. The authors think that the use of progressive tension suture at closing donor site can decrease the formation of dead space and ultimately reduce the incidence of donor site seroma. Methods: A retrospective review was performed with 38 patients who underwent latissimus dorsi muscle harvest for breast reconstruction from March 2003 to September 2004. Progressive tension sutures were used during donor site closure in 22 patients. This group was compared with controls group(16 patients) who underwent latissimus dorsi muscle harvest without using this technique. Operation time, length of hospital stay, period of drainage, complication, and satisfaction about postoperative scar of donor site were examined. Results: The average length of hospital stay was 10.2 days and 12.7 days, and the mean duration of drainage were 7.3 days and 11.7 days in each progressive suture group and control group. These results were statistically significant (p<0.05). In the 22 patients who underwent progressive tension suture, none had seroma, hematoma or skin necrosis. In control group(16 patients), there happened one seroma formation and one partial skin necrosis. These complications were healed by aspiration of seroma and wound revision. The patients' satisfaction was not statistically significant, but the higher points were given by the patients who underwent progressive tension suture. Conclusion: This technique, progressive tension suture, is an effective method to reduce or eliminate donor site seroma, which is the most common complication associated with latissimus dorsi muscle harvest.

Development of Commercial-scaled Pervaporation Hollow Fiber Membrane System for High Pressure and High Temperature Applications (고온 고압용 상업적 규모의 중공사 투과증발 막시스템 개발)

  • Yeom, Choong Kyun;Kang, Kyeong Log;Kim, Joo Yeol;Ahn, Hyo Sung;Kwon, Konho
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.257-266
    • /
    • 2013
  • The main purpose of this study is to develop a commercial scale of pervaporative process equipped with hollow fiber membrane modules, being able to effectually purify organic solvent at high temperature well over its boiling point under high vapor pressure. Three constituent technologies have been developed; 1) to fabricate braid-reinforced hollow fiber membrane stable in high pressure and high temperature application, 2) to design and fabricate a commercial scale of hollow fiber membrane module, and 3) to design and fabricate a pilot scale of pervaporation equipment system. The developed hollow fiber membrane possesses a membrane performance superior to the membrane of Sulzer (Germany) which is the most-well known for pervaporation process, and the membrane module equips hollow fiber membranes of $4.6m^2$ and the pervaporation system can treat organic liquid at 200 L/h, which is based on the dehydration of 95 wt% isopropyl alcohol (IPA). Since the membrane module is designed to flow in and pass through the inside of individual hollow fiber membrane, not to involve both the formation of feed's dead volume observed in flat-sheet membrane module and the channeling of feed occurring inside hollow fiber bundle which lower membrane performance seriously, it showed excellent separation efficiency. In particular, the module is inexpensive and has less heat loss into its surrounding, in compared with flat-sheet membrane module. In addition, permeant can be removed effectively from the outer surface of hollow fiber membrane because the applied vacuum is conveyed uniformly through space between fibers into respective fiber, even into one in the middle of the hollow fiber bundle in which the space between fibers is uniform in distance. Since the hollow fiber membrane pervaporation system is the first one ever developed in the world, our own unique proprietary technology can be secured, preoccupying technical superiority in export competitive challenges.

Fuel cell system for SUAV using chemical hydride - II. Lightweight fuel cell propulsion system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - II. 경량 연료전지 추진 시스템)

  • Hong, Ji-Seok;Park, Jin-Gu;Sung, Myeong-Hun;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.233-239
    • /
    • 2013
  • A 100 W fuel cell system using chemical storage method has been applied for a propulsion system of the SUAV(Small Unmanned Aerial Vehicle). A fuel cell and battery have been combined for both the small/light hydrogen generation control system and the hybrid power supply system. A small hydrogen generation device was implemented to utilize NaBH4 aqueous solution and dead-end type PEMFC system, which were evaluated on the ground and by the flight tests. The system pressurized at a 45kpa stably operates and get higher fuel efficiency. The pressure inside of the hydrogen generation control system was maintained at between 45 kPa and 55 kPa. The 100W fuel cell system satisfies the required weight and power consumption rate as well as the propulsion system, and the fuel cell system performance was demonstrated through flight test.

Fuel cell system for SUAV using chemical hydride - I. Lightweight hydrogen generation and control system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - I. 경량 수소 발생 및 제어 장치)

  • Hong, Ji-Seok;Jung, Won-Chul;Kim, Hyeon-Jin;Lee, Min-Jae;Jeong, Dae-Seong;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A compact hydrogen generation device of fuel cell system using chemical hydride storage technique was designed to fit the propulsion device requirement of a small unmanned aerial vehicle(SUAV). For high efficient, compact, and lightweight hydrogen generation control device, the Co-B catalyst hydrogen conversion rate by $NaBH_4$ aqueous solution flux is measured so that the proper amount of Co-B catalyst for maximum hydrogen generation of 100W stack was proposed. A compact hydrogen generation device is controlled by pump's on/off using its own internal pressure and consumes fuel in high efficiency through a dead-end type fuel cell. The fuel cell system has stable operation for a planed flight profile. The system operates up to maximum 7 hours and at least 4 hours for tough flight profiles.

Quality Assurance of Air Kerma Strength for Ir-192 High Dose Rate Source (Ir-192 고선량률 선원에 대한 공기커마강도의 품질보증)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.147-151
    • /
    • 2007
  • AAPM TG43 report has recommended to measure air kerma strength with the strength of source. Main purpose of this study is to verify the accuracy of air kerma strength provided by manufacturer. Materials for this study were MAX-4001 Electrometer, HDR 1000 Plus of the corporation of standard imaging, and 6 french bronchial Applicator with 1000 mm. we measured ionization current in 10-90 mm range from the bottom of the central axis of chamber. The reference point of calibration displayed by the maximum ionization current in the ionization current curve was measured, and air kerma strength was computed from the maximum ionization current. we acquired 50 mm distance to correspond with the maximum ionization current in the ionization current curve. Its distance has perfectly fitted to the source reference point of calibration certificate of UW-ADCL. Air kerma strength computed value has measured about 0.5% more than calibration value provided by manufacturer. Air kerma strength of calibration certificate provided by manufacturer has acquired reliable results. This study shows that considering the move error of dwell position of source and the dead space length in well-type chamber is a good way to get an accurate result.

  • PDF

The Management Methods of Multi-Purpose Ecological Reservoir by System Thinking - Focused on Anteo Eco Park - (시스템 사고를 통한 다기능 생태저류지의 관리방안 - 광명 안터생태공원을 중심으로 -)

  • Lee, HyunJi;You, Soojin;Chon, Jinhyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.2
    • /
    • pp.1-17
    • /
    • 2015
  • Ecological reservoir is a multifunctional space where provides the functions of retention, animal habitat and improvement of ecosystem health and landscape. The ecological reservoir of Anteo Eco Park located in Gwangmyeong-si has established to functions for water purification, maintenance of healthy aquatic ecosystem. Because the Anteo Eco Park is located in the site where nonpoint pollutant materials flow in, Anteo Eco Park has potential factors which aquatic ecosystem health deteriorates and damages the habitat of golden frog(Rana plancyi chosenica) which is restoration target species. Therefore, the purpose of this study is to suggest the plan to manage the variables which impede the right functions of aquatic ecosystem by understanding the causal loop diagram for the change of water quality environment and the interaction of predator-prey through system thinking. The results are as follows. First, the study showed that the individual number of golden frog which is an indicator species of Anteo Eco Park is threatened by snakeheaded fish, which is an upper predator. Therefore, balanced food chain should be hold to protect golden frog by capturing the snakeheaded fish which is individual number's density is high, and the monitoring management of the individual number for predator(snakeheaded fish)-prey(golden frog) should be performed. Second, the study represented that water pollution and carnification is caused by the sediment as the dead body of the large emergent vegetation in the winter cumulates as sediment. Ecological reservoir in Anteo Eco Park has been managed by eliminating the dead body of the large emergent vegetation, but the guideline for the proper density maintenance of vegetation community is additionally needed. Lastly, the study showed that aquatic ecosystem of Anteo Eco Park where is contaminated from the inflow of nonpoint pollutants affects the individual number's decline of golden frog and snakeheaded fish. Accordingly, the creation of a buffer area and a substitution wetland is needed in the periphery of the Anteo Eco Park to control the inflow of nonpoint pollutants including organic matters, nutrients and heavy metals. This study will be helpful that Anteo Eco Park improves the regional landscape and maintain healthy aquatic ecosystem space for the park visitors including local residents.