• Title/Summary/Keyword: Dc breakdown strength

Search Result 51, Processing Time 0.053 seconds

Analysis of DC dielectric breakdown strength of Nano-composite insulation material for HVDC Cable (HVDC용 나노복합 절연재료의 DC절연파괴 분석)

  • Cho, Sung-Hoon;Jung, Eui-Hwan;Lee, Han-Ju;Lim, Kee-Joe;Jeong, Su-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.104-104
    • /
    • 2010
  • With the advent of nano-particle fillers in insulating materials, the insulating materials of superior quality have come to fore. In the recent past, nanocomposite LDPE/XLPE (Low Density Polyethylene/Cross Linked Polyethylene) power cable dielectrics have been synthesized. A preliminary evaluation of these new class of materials seem to show that, addition of small amounts of sub-micron inorganic fillers improved the dielectric properties of the composite, in particular, the volume resistivity, and the DC breakdown strength. The thermal behaviour, for example, the stability of composites against decomposition and ensuing electrical failure, do not seem to have been addressed. In a conventional XLPE insulated cable, the average thermal breakdown strength and maximum temperature at the onset of breakdown were seen to be markedly lower than the corresponding intrinsic breakdown strength and decomposition temperature. In this page, analysis of DC Breakdown of nano-composite insulating material for HVDC Cable is introduced.

  • PDF

Copper Particle Effect on the Breakdown Strength of Insulating Oil at Combined AC and DC Voltage

  • Wang, You-Yuan;Li, Yuan-Long;Wei, Chao;Zhang, Jing;Li, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.865-873
    • /
    • 2017
  • Converter transformer is the key equipment of high voltage direct current transmission system. The solid suspending particles originating from the process of installation and operation of converter transformer have significant influence on the insulation performance of transformer oil, especially in presence of DC component in applied voltage. Under high electric field, the particles easily lead to partial discharge and breakdown of insulating oil. This paper investigated copper particle effect on the breakdown voltage of transformer oil at combined AC and DC voltage. A simulation model with single copper particle was established to interpret the particle effect on the breakdown strength of insulating oil. The experimental and simulation results showed that the particles distort the electric field. The breakdown voltage of insulating oil contaminated with copper particle decreases with the increase of particle number, and the breakdown voltage and the logarithm of particle number approximately satisfy the linear relationship. With the increase of the DC component in applied voltage, the breakdown voltage of contaminated insulating oil decreases. The simulation results show that the particle collides with the electrode more frequently with more DC component contained in the applied voltage, which will trigger more discharge and decrease the breakdown voltage of insulating oil.

The variation of water absorption rate and DC dielectric breakdown strength of Epoxy composites due to filler content (충진재 함량 변화에 따른 에폭시 복합재료의 흡수율과 직류 절연파괴강도의 변화)

  • Lee, D.J.;Kim, T.Y.;Shin, S.K.;Kim, M.H.;Kim, K.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2349-2351
    • /
    • 1999
  • In this paper, the variable absorption rates and DC dielectric breakdown strength of epoxy composites were measured at boiling absorption condition in order to observe the influences of moisture in out door use. Also, in order to improve withstand voltage properties at moisture absorbtion condition. IPN (interpenetrating polymer network) method which had been already reported, was introduced and the influence was investigated. As a result, it was confirmed that the moisture absorption rate was increased and DC dielectric breakdown strength was degraded with boiling time and filler content increasing. On the other hand, it was confirmed that moisture absorption rate and DC dielectric breakdown strength degrading rate were lowered by the improvement of adhesion strength In IPN specimens.

  • PDF

Dielectric Breakdown Characteristics of PPLP and GFRP for HTS DC Cable System (고온초전도 DC 케이블 시스템용 PPLP 및 GFRP의 절연 특성)

  • Kim, S.H.;Choi, J.H.;Kim, W.J.;Jang, H.M.;Lee, S.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.3
    • /
    • pp.5-9
    • /
    • 2011
  • DC high-temperature superconducting(HTS) cable system has attracted a great deal of interest from the view point of low loss, dense structure and large capacity. A HTS cable system is made of cable and termination. The insulating materials and insulation technology must be solved for the long life, reliability and compact of cable system. In this paper, we will report on the dielectric breakdown characteristics of insulating materials for HTS cable and termination. The AC, DC and lightning impulse breakdown strength of laminated polypropylene paper(PPLP) and glass fiber reinforced plastic(GFRP) have been measured under nitrogen pressures in the range of 0.l-0.4MPa. PPLP and GFRP are found to have a significantly higher DC breakdown strength. Also, DC surface flashover voltage of negative polarity is slightly higher than that of positive polarity in GFRP.

A Study on Improvement of DC Breakdown Strength due to Interface Treatment Effect of Epoxy/$SiO_2$ Compund Material for Electrical installation (전기설비용 Epoxy/$SiO_2$ 복합재료의 계면처리 효과에 따른 직류 절연파괴 강도의 개선에 관한 연구)

  • 김재환;박창옥;김경환;김명호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.2
    • /
    • pp.51-55
    • /
    • 1992
  • In this study as treating to filter silance coupling agent (KM-6030 improving coupling strength between matrix resin (bisphenole-A type epoxy resin) and filler (SiO2), breakdown strength was investigated on cases applying DC voltage to specimen. In the case on DC voltage, breakdown strength was improved bout 12.73% and 10.77% in specimen of 5[wt%] and 50[wt%] of filler content of 10 of epoxy. Therefore, it was investigate the effect that concentration of coupling agent and content of filler was influential on breakdown strength of epoxy resin.

  • PDF

Electrical Breakdown Strength of Insulation under Combined DC-AC Voltages

  • Grzybowski, S.
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.32-39
    • /
    • 1998
  • Electrical breakdown strength of paper-oil and polypropylene/film-oil insulation samples was measured under dc, ac and pulsating voltages. The latter was obtained by superimposing ac upon dc volate and provides an attractive method for a simultaneous testing and assessment of the state of insulation of the various parts of HV apparatus in service. The measurements were carried out over a wide range of the pulsation ratio defined as p=Eac/Edc. The results obtained under pulsating voltages follow colsely an experssion which relates the breakdown strength to the sum of arc tangent and arc cotangent function of the parameter p. The study was carried out using dry paper as well as paper containing various degrees of moisture. The presence of moisture showed a pronounced effect upon the breakdown strength which varied with the pulsation parameter p.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 절연 신뢰도 평가)

  • 임중관;박용필;김정호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.92-95
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 [Mv/cm].

  • PDF

The Influence of Gap Length and Tip Radius on Breakdown of Electrical Insulating Oil (전기절연유의 절연파괴에 미치는 전극간격 및 곡률반경의 영향)

  • Kang, Seong-Hwa;Chae, Hong-In;Lee, Jong-Pil;Lim, Kee-Joe
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.56-59
    • /
    • 2004
  • In this paper, we investigated the influence of gap length and tip radius on breakdown of mineral based insulation oil. Applied voltages were DC and AC voltage. Electrode system was needle-plane structure. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}m$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. Electric breakdown strength at tip was calculated using Mason's equation contained geometric figure. As gap length increased, breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by the phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage, breakdown strength was higher when polarity of needle was negative than positive. It is because of the space charge effect in accordance with the influence of liquid motion.

Breakdown Characteristic of Transformer Oil Depending on Tip Radius (침전극 곡률 반경에 따른 절연유의 절연파괴 특성)

  • Lee, J.S.;Jeong, S.H.;Lee, H.K.;Lim, K.J.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1478-1480
    • /
    • 1997
  • We investigated the breakdown characteristic of mineral oil according to applied voltage and tip radius. In this experiment, electrode system was point-plane geometry. The tip radius of needle was 5, 10, 20 and $25{\mu}m$, respectively. Applied voltage was AC and DC. We measured breakdown voltage for each tip radius with increasing electrode gap, 2mm to 10mm. Under nonuniform electric field, breakdown strength was higher when needle was negative than when needle was positive. Because it is polarity effects due to space charge. And the more sharp tip radius, whether we applied AC or DC, the higher breakdown strength. As tip radius increase, breakdown strength decreases exponentially.

  • PDF

Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation (전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰)

  • Lee, Han-Joo;Jung, Eui-Hwan;Joe, Sung-Hoon;Yoon, Jae-Hoon;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF