• 제목/요약/키워드: Dc Distribution

검색결과 596건 처리시간 0.027초

LCL 필터가 적용된 직류배전용 3-Level NPC AC/DC PWM 컨버터의 예측제어기법 (The Predictive Control Method of 3-Level NPC AC/DC PWM Converter applying LCL Filter for DC distribution)

  • 홍석진;강동주;현승욱;강진욱;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.71-72
    • /
    • 2015
  • 본 논문에서는 LCL필터가 적용된 대용량 3-Level NPC AC/DC PWM 컨버터의 출력 DC 전압 동특성을 향상시킬 수 있는 방법으로 예측제어기법을 적용하였다. 예측제어를 위하여 LCL필터와 3-Level NPC 컨버터를 모델링하고, 시뮬레이션을 통하여 제안하는 방법의 제어성능을 검토하였다.

  • PDF

DC 절연파괴 특성을 이용한 Epoxy 복합체의 절연 신뢰도 평가 (Evaluation of Insulating Reliability in Epoxy Composites by DC Dielectric Breakdown Properties)

  • 임중관;박용필;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.92-95
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 [Mv/cm].

  • PDF

신재생에너지 밀집 연계 배전망의 DC화에 따른 효율성 분석 및 ESS 활용방안 검토 (Efficiency Analysis of DC application on RES concentrated distribution system and utilization plan for ESS)

  • 고보경;송성윤;신병윤;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.255-256
    • /
    • 2015
  • The increasing penetration of renewable energy based distributed generation(DG) sources in low-voltage grid feeders has been receiving increased attention. High penetration of renewable energy generation in a distribution system can cause power quality and efficiency problem. In this paper, the operating plan for ESS and the efficiency analysis on RES(Renewable energy source) concentrated distribution system.

  • PDF

인쇄 회로 기판용 에폭시 복합체의 첨가제에 따른 절연 신뢰도 (Insulating Reliability according to additives in Epoxy Composites for PCB Material)

  • 양정윤;박영철;박건호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.159-163
    • /
    • 2003
  • In this study, the DC dielectric breakdown of epoxy composites used for PCB material was experimented and then its data were simulated by Weibull distribution equation. The more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical, and the breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. From the analysis of Weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5[kV/mm].

  • PDF

HDPE/EVA혼합수지의 공간 전하 분포에 관한 연구 (A Study on Space Charge Distribution of HDPE Mixed with EVA)

  • 정의환;허준;윤재훈;임기조;이흥규
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2229-2235
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately, it resulted from extinction of space charge in the interfacial region of spherulites.

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

독립형 DC 마이크로그리드의 최적화 설계와 협조적 제어 (Optimized Design and Coordinated Control for Stand-alone DC Micro-grid)

  • 한태희;이지헌;김현준;한병문
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2013
  • This paper describes the coordinated droop control method for stand-alone type DC micro-grid to improve reliability and utilization of distributed generations and energy storage. The stand-alone type DC micro-grid consists of several distributed generations such as a wind power generation, solar power and micro-turbine, and energy storage. The proposed method which is based on autonomous control method shows high reliability and stability through coordinated droop control of distributed generations and energy storage and also capability of battery management. The operation of stand-alone type DC micro-grid was analyzed using detail simulation model with PSCAD/EMTDC software. Based on simulation results, a hardware simulator was built and tested with commercially available components and performance of system was verified.

KSTAR 용 소선-소선 접합부의 직류저항 계산 (Calculation of DC resistance of strand-to-strand joints for KSTAR)

  • 이호진;남현일;김기백;홍계원
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.104-110
    • /
    • 2001
  • Since the strand-to-strand type joint far CICC (Cable-In-Conduit Conductor) is small in size and has low DC resistance, it is expected to be useful type fur a superconducting magnet system which had a compact structure like the KSTAR (Korea Superconducting Tokamak Advanced Research) coil system. The DC resistance is changed according to the distribution patterns of strands in cables connected together in the joint. A commercial code was used for the calculation of the DC resistance. With the decrease of outer diameter of the Joint, Which means the increase of strand volume fraction in the joint, the calculated DC resistance decrease rapidly and non-lineally. The variation of resistance depends mainly on the volume fraction of solder which has higher resistivity than copper. The resistance decrease inversely with the increase of the length of the joint. The resistance increase with increase of number of triplets in each stack contacted with that of another terminal cable. In case of the strand-to-strand joint that has 62mm of outer diameter, 52mm of inner diameter, 100mm of overlap length, and four triplets in each stack, the calculated DC resistance is less than 1 n-Ohm.

  • PDF

Droop 제어를 기반으로 한 직류 마이크로그리드의 자율 동작 분석 (Autonomous Operation Analysis of DC Microgrid based on Droop Control)

  • 이지헌;김현준;한병문
    • 전력전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.342-350
    • /
    • 2011
  • 본 논문에서는 분산전원으로 풍력과 태양광, 에너지저장으로 배터리, 직류부하, 그리고 교류연계전력망으로 구성된 직류 마이크로그리드에서 Droop 제어를 기반으로 한 시스템의 자율동작을 분석한 내용에 대해 기술하고 있다. 자율동작의 분석을 위해 먼저 PSCAD/EMTDC 소프트웨어를 이용해 각 분산전원과 배터리의 시뮬레이션 모델을 개발하고 이를 바탕으로 Droop 제어를 검증하였다. 또한 시뮬레이션 결과를 바탕으로 3kW급 DC마이크로그리드의 하드웨어를 제작하여 실제적인 자율동작의 타당성을 분석하였다.

비충전 및 충전 원형기둥-상자형보 접합부의 응력분포특성 (Stress Distribution Behavior Hollow and Felled Circular Column Column-Box Beam Connections)

  • 황원섭;박용명;최원경;김영필
    • 한국강구조학회 논문집
    • /
    • 제14권3호
    • /
    • pp.433-441
    • /
    • 2002
  • 본 연구에서는 원형기둥과 상자형보로 이루어진 접합부의 응력분포에 관하여 검토하였다. 접합각도를 변수로 하는 총 12개의 비충전 및 충전 원형기둥-상자형보 접합부에 대한 실험을 수행하였다. 접합부의 수직 및 전단응력 분포특성을 파악하기 위해 우선 기존 설계식에서 주로 사용하고 있는 환산깊이 dc'및 추가적의 환산깊이를 도입하여 검토하였고 이를 적용하여 계산한 응력값을 실험값과 비교.검토하였다. 그 결과 비충전 및 충전접합부의 수직 및 전단응력 실험값은 설계식에 의한 값과 많은 차이점을 나타냄을 알 수 있었고, 환산깊이 dc'은 접합각도가 커질수록 급격히 감소하여 설게식에 적용하기에는 한계가 있음을 확인하였다. 또한 충전 접합부가 비충전 접합부에 비해 작은 응력값을 나타냈으며 충전접합부의 실험값을 비충전 접합부의 응력산정 방법을 준용하는 현행 설계식의 값과 비교. 분석하였다.