• Title/Summary/Keyword: Daylight Optimization

Search Result 10, Processing Time 0.021 seconds

Study on Integrated Workflow for Designing Sustainable Tall Building - With Parametric method using Rhino Grasshopper and DIVA for Daylight Optimization

  • Kim, Hyeong-ill
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The Objective of this study is to explore the capabilities of an integrated modelling and simulation workflow when applied to an experiment-based research process, aimed at deriving daylight optimization strategies specific to tall buildings. Methods: Two methods were devised to apply this workflow with the help of DIVA and Rhino/Grasshopper. The first method is a multiple variant analysis by setting up an appropriate base case and analysing its daylight and energy performance, forming the basis of comparison for subsequent cases for design variants. The second method involved setting up the base case within a site context and conducting a solar irradiation study. An architectural variables such as overhang and shading device, were then defined as inputs in the parametric definition in Grasshopper to control the selected variable. Results: While the first method took advantage of the speed and efficiency of the integrated workflow, the second method was derived based on the ability to directly process simulation data within the integrated, single-software platform of the proposed workflow. Through these methods, different architectural strategies were explored, both to increase daylight penetration and to reduce radiant heat gain. The focus is on methods by which this workflow can be applied to facilitate the experimental derivation of daylight optimization strategies that are specific to tall building design.

A optimization of photosensor shape for daylight responsive dimming systems (광센서 조광제어시스템의 효율적인 광센서 형상에 관한 연구)

  • Joo, Keun-Tak;Park, Byeong-Cheol;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.195-199
    • /
    • 2004
  • The most important role of photosensor is to measure on exact workplan illuminance of room when daylight responsive dimming systems are used. The shape of most optimal photosensor must be able to measure exact luminous flux without changing setting position corresponding to the change of room situations. That is, shape and positioning of optimal photosensor should be corresponded to the optimal luminous flux measurement.

  • PDF

A Study on System Optimization according to the Supply Obligations Rate of New and Renewable Energy at an Indoor Gymnasium (실내체육관의 신재생에너지 공급의무비율에 따른 시스템 최적화 연구)

  • Park, Yun-Ha;Kim, Yun-Ho;Won, An-Na;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.51-60
    • /
    • 2015
  • In statutes on the promotion of distribution of new and renewable energy, which were revised in 2014, daylight system and fuel cell were added in addition to existing new and renewable energy sources. This study, therefore, aimed at setting up targets for the introduction of daylight system and analyzing the installation rate of new and renewable energy which can be provided by daylight system for the aggressive use of daylight system, thereby deducting the optimal combination ratio with other new and renewable energy sources. The results of the study are as follows. First, when a prism-shaped daylight system was installed to a round indoor gymnasium among domestic indoor gymnasiums, out of a supply obligations allotment rate of 15% of new and renewable energy, the rate of daylight system was basically set at 2.5%. Second, therefore, with daylight system coming first, the lacked supply obligations rate was taken up by solar photovoltaic, solar heat and geothermal heat. In addition, using the KRESS Program, economic, technical, environmental and complexity evaluations for the upper 5% was made, deducting the optimal ratio of the system. The results produced the following optimal combination ratios: solar photovoltaic (83.3%) in economic evaluation, solar heat (8.3%) and geothermal heat (75%) in technical evaluation, solar photovoltaic (83.3%) in environmental evaluation, and solar photovoltaic (83.3%, the same as in economic evaluation) in complexity evaluation.

A Fundamental Study of Optimization to Control on Height of Roller Shade in Office Building through Mock-up Experiment (Mock-up 실험을 통한 사무소 건축물의 Roller Shade 높이 제어 최적화에 관한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.148-153
    • /
    • 2008
  • An inflow of daylight to the room offers comfortable view environment, psychological and physical security to people in the room and there are merits such as a work efficiency and energy saving. But, it has many problems as an excessive direct sunlight, cooling and heating. We can expect to have energy saving effect for illumination with comfortable view environment creation through control on height of roller shade. This study will be a used a fundamental approach to control on height of roller shade to changing daylight.

  • PDF

Performance Analysis and Optimization of OpenDaylight Controller in Distributed Cluster Environment (분산 클러스터 환경에서 오픈데이라이트 컨트롤러 성능 분석 및 최적화)

  • Lee, Solyi;Kim, Taehong;Kim, Taejoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.11
    • /
    • pp.453-462
    • /
    • 2017
  • OpenDaylight is an SDN (Software Defined Networking) open source framework, which is popular in network fields recently. This paper analyzes the performance of a controller cluster architecture by focusing on distributed datastore and Raft leader election algorithm. In addition, we propose an enhanced version of Raft algorithm in order to improve the performance of distributed datastore by distributing shard leaders over controller cluster. This paper compares the conventional Raft algorithm with the proposed version of the Raft algorithm. Moreover, we compare the performance of distributed datastore according to shard roles such as leader and follower. Experimental results show that Shard leaders provide better performance than followers and Shard updating requests need to be distributed over multiple controllers. So, by using proposed version of Raft algorithm, controller performance can be improved. The details of the experiment results are cleary described.

Daylighting Design Factors for Korean Dementia Nursing Homes Based on the Therapeutic Effects of Light (빛에 의한 치료적 효과 기반의 한국형 치매요양시설의 자연채광 계획 요소에 관한 고찰)

  • Jee, Soo In
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.71-87
    • /
    • 2022
  • Purpose: This study examines the daylighting design factors of Korean dementia nursing homes, in order to realize a therapeutic environment based on the therapeutic effect of light in the rapidly aging trend with an huge increase in the population of dementia in Korea. Methods: Through literature reviews, this study aims to theoretically examine the therapeutic light environment for the elderly with dementia, derive daylighting design factors of Korean dementia nursing homes, and analyze their detailed design factors. Results: The result of this study can be summarized into two points. The first one is that the daylighting design factors reflected in dementia nursing homes are derived into six factors: building layout, windows, glazing, shading devices, spaces, and interior finishings that determine the availability of daylight. The second one is that the detailed daylighting design factors are shown as primary and secondary detailed design factors, and the main values to be considered when applying these factors into dementia nursing homes are analyzed as maximizing daylight availability, optimization of the possibility of therapeutic view, and anti-glare. Implications: The daylighting design factors will contribute to maximizing the availability of daylight, optimizing the possibility of view, and minimizing the glare in the living spaces of dementia nursing homes in Korea.

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

Toward Net-Zero Energy Retrofitting: Building-Integrated Photovoltaic Curtainwalls

  • Kim, Kyoung Hee;Im, Ok-Kyun
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.35-43
    • /
    • 2021
  • With the rapid urbanization and growing energy use intensity in the built environment, the glazed curtainwall has become ever more important in the architectural practice and environmental stewardship. Besides its energy efficiency roles, window has been an important transparent component for daylight penetration and a view-out for occupant satisfaction. In response to the climate crisis caused by the built environment, this research focuses on the study of net-zero energy retrofitting by using a new building integrated photovoltaic (BIPV) curtainwall as a sustainable alternative to conventional window systems. Design variables such as building orientations, climate zones, energy attributes of BIPV curtainwalls, and glazed area were studied, to minimize energy consumption and discomfort hours for three cities representing hot (Miami, FL), mixed (Charlotte, NC), and cold (Minneapolis, MN). Parametric analysis and Pareto solutions are presented to provide a comprehensive explanation of the correlation between design variables and performance objectives for net-zero energy retrofitting applications.

High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method (제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식)

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Whang, Ki-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

Optimization of the extraction procedure for quantitative analysis of saponarin and the artificial light condition for saponarin production from barley sprout (고함량 사포나린 함유 보리 어린 순 재배를 위한 식물공장내 인공광 조건 및 사포나린 추출 분석법 최적화)

  • Oh, Kyeong-Yeol;Song, Yeong Hun;Lee, Duek-Yeong;Lee, Tae-Geun;Kim, Jin-Hyo
    • Journal of Applied Biological Chemistry
    • /
    • v.64 no.3
    • /
    • pp.197-203
    • /
    • 2021
  • Saponarin is a crucial component of barley sprout, and the production and quantitative analysis are issued to date. In this study, the optimal saponarin extraction conditions were presented on the subject of acetonitrile, ethanol, methanol, and water for the quantitative analysis in barley sprout through the extraction efficiency compared with the solvent concentration and extraction time using the reaction surface methodology. The optimal extraction time and solvent condition for saponarin were 3.9 h and 53.7% of aqueous methanol, respectively. In addition, the effect of LED artificial light on the saponarin production in barley sprouts was evaluated by the light cycle, light quantity, and light quality. The optimal cultivation conditions under artificial light for the growth of barley sprout and saponarin production were most effectively achieved on 220-320 μmol m-2 s-1 of the light quantity with 8 h day-1 of a daylight cycle under 6500K LED combined with red light. Furthermore, blue light was evaluated as the main factor in the biosynthesis of saponarin.