• Title/Summary/Keyword: Daylight Distributions

Search Result 19, Processing Time 0.019 seconds

A Study on Prediction Method of Sky Luminance Distributions for CIE Overcast Sky and CIE Clear Sky (CIE 표준 담천공과 청천공 모델의 천공 휘도분포 예측 방법에 관한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.33-43
    • /
    • 2016
  • Daylight is an important factor which influences building energy efficiency and visual comfort for occupants. It is important to predict precise sky luminance at the early stages of design to reduce light energy in the building. This study predicted sky luminance distributions of standard sky model(CIE overcast sky, CIE clear sky) that was provided from the CIE(Commission internationale de $l^{\prime}{\acute{e}}clairage$). Afterward, result of sky luminance was compared and verified with simulation value of Radiance program. From the CIE overcast sky, zenith and horizon ratio is about 3:1. From the CIE clear sky, luminance value gets most high value around the sun. On the other hand, luminance value is the lowest in the opposite direction of the sun when angle is $90^{\circ}$ between the sun and sky element. As a result of comparing the calculation results with Radiance program, sky luminance prediction error rate is 0.4~1.3% when it is CIE overcast sky. Also, sky luminance prediction error rate is 0.3~1.5% when it is CIE clear sky. When compared with the results of radiance simulation, it was evaluated as fairly accurate.

A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load (냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구)

  • An, Hyung-Jun;Kim, Young-Tag;Choi, Chang-Ho;Lee, Hyn-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

The Variation in Chromaticity of Optical System having the Truncated Incident Beam (입사광의 단락된 정도에 따른 광학계의 색도 변화)

  • Park, Seong Jong;Chung, Chang Sub;Sim, Sang Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 2000
  • In this paper, we use the C light which is a daylight and consider the incident beam having the Gaussian amplitude. We investigated the illuminance distributions and the variation in chromaticity of optical system having the truncated Gaussian amplitude on the focal plane and along the optical axis using the C light source. We also use the three sensitivity functions of human eye(CIE 1931) for wavelengths which are from 380nm to 780nm. When the truncation grade of incident beam having Gaussian amplitude decreases, the size of central spot on the focal plane and the depth of focus along the optical axis decrease, and the variation in chromaticity on the focal plane and along the axis increases rapidly. As the illuminance on the focal plane decreases the variation in chromaticity of optical system increases rapidly, and as the depth of focus increases the variation in chromaticity of optical system decreases.

  • PDF

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting (자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han;Han, Sang-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

Study on the Characteristics of Surface Ozone Distributions and the Ozone Critical Levels to Vegetation in the South Korea (남한 지역의 지면 오존 농도 특성과 식생에 대한 임계값 적용 연구)

  • Koo, Hae-Jung;Park, Soon-Ung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2008
  • Concentration of tropospheric ozone ($O_3$) was investigated for the South Korea. And then the critical ozone levels, expressed as AOT40 (Accumulated exposure over a threshold of 40 ppb) to vegetation have been used in this region within the UNECE (United Nations Economic Commission for Europe) Convention on Long-Range Trans-boundary Air Pollution (CLRTAP). Hourly ozone concentration data from 1996 to 2001 at 26 air monitoring stations was used to estimate the exceedance of the critical levels. It was calculated for daylight hours for each station, and mapped using surface interpolation over the South Korea. The critical levels of ozone have shown the highly exceeded value in the Gyeonggi region, southern coastal region and central inland of the South Korea. It was some different from the typical ozone distribution which represented highly in the western inland and coastal regions. The area exceeding the critical level for crops was founded to be more than 40% of the whole South Korean territory. While that for trees was to be about 17% of the South Korea. The critical ozone critical level was based upon data from experiments on specific species, and thus may not be fully representative for all types of vegetation. Nevertheless, the critical level and its exceedance of the ozone concentration would be one of the useful tools for international agreements on abatement strategies to prevent ecosystem damage.

A Color Analysis on Working Clothing in Domestic Machine and Heavy Industry

  • Park, Hye-Won;Bae, Hyun-Sook;Park, Jin-Ah;Kim, Jie-Kwan
    • Journal of Fashion Business
    • /
    • v.13 no.6
    • /
    • pp.61-75
    • /
    • 2009
  • The objective of this research is to the enhance the color function of work clothing : to research and analyze the hue and tone of work clothing colors to be used for machinery and heavy industries in national industrial complexes, Through this research, the color using problems which related with safety workers will be revealed. For this project, total 42 sets of work suits were sampled from 12 different companies in the machinery and construction industries in the national industrial complexes of Gyeongsang Namdo Province and 16 sets of work suits currently being sold in the market. The collected work suits samples were classified according to item types and design. Color measurements were taken thus: After calibration according to ASTM D1729 specifications of standardized configuration settings to match standardized luminous source D65(Daylight 6500K) in color cabinet BOTECK SuperLight-VI, the RGB values of the work suits were calculated using PANTONE Color Cue TX. The RGB values of the colors thus derived were converted into V/C values using the Munsell Conversion 9.0.6 and analyzed with Munsell's 10-color system and PCCS. The results were presented according to Munsell's color wheel and color and brightness distributions were expressed in table form, as well as presented as a tone map. Following analysis, color hue distribution was found to be concentrated around PB, and brightness distribution toward the low end and mid range of the scale. Saturation values were distributed mostly around the low end of the scale. Following color tone analysis according to PCCS, it became apparent that colors were mainly distributed around dkg, ltg, and g, at low- and mid-brightness and low-saturation. Therefore, it may be concluded that colors used in work suits in the machinery and heavy industries are mainly cool colors, at low- and mid-brightness and low saturation. It is conjectured that such colors were applied uniformly in the workplace in order to serve certain functions, such as concealment of stains and contamination. Therefore, it follows that the utilization of colors, among other functions served by working clothings, must be taken into consideration in order to enhance safety and efficiency.

A Study on Visual Comfort for Light Control Method of Applied Daylighting (자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Han, Sang-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF

Studies on the Epidemiology and Control of Bacterial Leaf Blight of Rice in Korea (한국에 있어서의 벼흰빛잎마름병의 발생생태와 방제에 관한 연구)

  • Lee Kyung-hee
    • Korean journal of applied entomology
    • /
    • v.14 no.3 s.24
    • /
    • pp.111-131
    • /
    • 1975
  • The study has been carried out to investigate the occurrence, damage, characteristics of the pathogen, environmental conditions affecting the disease outbreak, varietal resistance, forecasting, and chemical control of bacterial leaf blight of rice in Korea since 1964. Bacterial leaf blight of rice became a major disease in Korea since 1960. A correlation was found between the annual increase of epidemics and increase of cultivation area of susceptible varieties, Jinheung, Keumnampung etc. Areal damage within the country showed that the more was at southern province, Jeonnam, Gyeongnam and western coast, and at flooded rice paddy. Yield reduction directly related with the amount of infection on upper leaves at heading stage. Fifty per cent of reduction resulted when the lesion area was more than 60 per cent. Less than 20 per cent of lesion area, however, was not affected so much on yield loss One hundred and six isolates collected from all over the country were classified as 8 strains by using 4 different bacteriophages in 1973. It was, however, only two in 1965. There were some specificities on varietal distributions among the strains such as that the Jinheung attacked mainly by strain A, B, C and I, those attack Kimmaze were A, B, H and I. Most strains were found from Tongil except D and E, whereas Akibare was only variety that attacked by strain E. Low temperature, high humidity, heavy rainfall and insutficient daylight favored the disease epidemics. Especially, typhoon and flooding at heading stage were critical factors. The earlier transplanting the more disease was resulted, and more nitrogen fertilizer application accerelated the diseased development in general. The resistance to the disease varied by growing stage of the sane plants. All of recommended varieties in Korea were susceptible to the disease except Norm No. 6 and Sirogane which moderately resistant. The pathogen, Xanthomonas oryzae, was detectable from extract of healthy seedlings that were grown in the field with an heavy infection previous year. The more bacteriophage in irigation water resulted the more disease outbreak, and the existence of more than 50 bacteriophages in 1ml. of irrigation water were necessary to initiate the disease out break. The curves representing occurrence of bacteriophages and disease outbreak were similar with 15 days interval. The survey of bacteriophage occurrence can be utilized in forecasting of the disease two weeks ahead of disease outbreak. Three applications of chemicals, Phenazin and Sangkel, in weekly intervals at the early satage of out-break depressed the symptom development, and increased yield by 20per cent. Proper period for the chemical application was just before the number of bacteriophage reaches 50 in 1ml. of irrigation water.

  • PDF

Determination of Total CO2 and Total Alkalinity of Seawater Based on Thermodynamic Carbonate Chemistry (해수중의 총이산화탄소와 총알칼리도 분석을 위한 탄산염 화학 이론 및 측정방법)

  • Mo, Ahra;Son, Juwon;Park, Yongchul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • To evaluate accuracy and precision of determination of total alkalinity ($Alk_T$) and carbon dioxide ($TCO_2$) derived from present study, experiment was applied with $CO_2$ CRM (Batch 132, Scripps Institution of Oceanography; $Alk_T=2229.24{\pm}0.39{\mu}mol/kg$, $TCO_2=2032.65{\pm}0.45{\mu}mol/kg$). As the result, average concentration of $Alk_T$ and $TCO_2$ was $2354.09{\mu}mol/kg$ (~5.6% difference with $CO_2$ CRM) and $2089.60{\mu}mol/kg$ (~2.3% difference with $CO_2$ CRM), respectively. For previous method (Gran Titration) by addition $NaHCO_3$ to deionized water($Alk_T$ $2023.33{\mu}mol/kg$), average concentration was $2193.39{\mu}mol/kg$ (sd=57.15, n=7). Whereas, average concentration was $2017.02{\mu}mol/kg$ (sd=10.98, n=7) for the present study. Recovery yield experiments of total alkalinity in deionized water and seawater were implemented by addition of $NaHCO_3$. The recovery yield of deionized water in the range 0 to $4952.39{\mu}mol/kg$ was 100.8% ($R^2$=0.999), and seawater in the range 0 to $2041.32{\mu}mol/kg$ was 102.3% ($R^2$=0.999). Comparison of $pCO_2$ sensor (PSI $CO_2-Pro^{TM}$) with present method showed very meaningful correlation coefficient ($R^2$=0.977) in the range of 427 to $705{\mu}atm$ and 9.16 to $15.24{\mu}mol/kg$ throught elapsed time for two weeks. Field experiment of diurnal variation of total carbon dioxide was accomplished at Sachon harbor in the coastal waters of East Sea of Korea. Concentration of $Alk_T$ and $TCO_2$ was increased during night, and decreased during daylight hours. The results showed mirror type between $TCO_2$ and dissolved oxygen, which was attributable to photosynthesis and respiration of phytoplankton. Also, open ocean field study was performed to obtain vertical profile of $Alk_T$ and $TCO_2$ in C-C zone (Clarion-Clipperton Fracture Zone), Northeastern Pacific. Average concentrations of $Alk_T$ in the surface mixed layer (0~60 m) and deeper layer below 200 m were $2422.38{\mu}mol/kg$ (sd=78.73, n=20) and $2465.87{\mu}mol/kg$ (sd=57.68, n=103), respectively. And average concentrations of $TCO_2$ were $2134.47{\mu}mol/kg$ (sd=65.4, n=20) and $2431.87{\mu}mol/kg$ (sd=65.02, n=103) in the same depth ranges such as $Alk_T$. Vertical distributions of $Alk_T$ and $TCO_2$ concentrations tended to increase with depth, and analyzed concentrations showed slightly higher than those of previous studies in this area.