• Title/Summary/Keyword: Data-Dependent Operation

Search Result 150, Processing Time 0.023 seconds

Experiments on a Regenerator with Thermosyphon for Absorption Heat Pumps (기포 펌프를 적용한 흡수식 열펌프용 고온 재생기의 작동 특성 실험)

  • Park, C.W.;Jurng, J.;Nam, P.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.463-472
    • /
    • 1996
  • Experiments were carried out to study the operation characteristics of a regenerator with a thermo-syphon pump and a surface-flame burner for a lithium bromide (LiBr)-water absorption heat pump. A cylindrical-shape metal-fiber burner and commercial grade propane were used. The emission of carbon monoxide and nitric oxide was measured by a combustion gas analyzer. Ther regeneration rate of water vapor as a refrigerant was measured. It could be as a reference value showing the performance of the regenerator. The circulation rate of the LiBr-water solution was also measured from both the tanks for the weak-and the strong-solution. Using a refractometer, the LiBr concetration in the solution was calculated from the measured refractory index of the solution. Temperature of the solution and the condensed water was recorded at several points in the experimental apparatus with thermocouples, using a personal computer. This data collecting system for measuring temperature was calibrated with a set of standard thermometers. The generating rate of water vapor as refrigerant increased linearly with heat supplied. It was about 4.0g/s with the heat supplied at a rate of 16,500kcal/h. The circulation rate of LiBr solution also increases with the heat supplied. The difference in LiBr concentrations between the weak and the strong solution was in the range of 1 to 5% when the concentration of the strong solution was about 60%. It was dependent upon both the heat supplied and the circulation rate of the solution. The initial concentration and the level of the LiBr solution in the regenerator were measured and recorded before experiments. The effect of them on the generating rate of water vapor and the circulation rate of the solution was also studied. The generating rate of water vapor was not strongly dependent upon both the level of the LiBr solution and the initial LiBr concentration. However, the concentration difference of the solution increases with the initial level of the LiBr solution.

  • PDF

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 모사)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 시뮬레이션)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Kang, Byung-Chan;Ra, Ho-Sang;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.488-493
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

  • PDF

Tracking Method of Inclination-dependent 2-axis Solar Tracker (경사각 종속형 2축식 태양광 추적기의 추적방식)

  • Hong, Jung-Hoon;Kim, Eun-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.180-187
    • /
    • 2013
  • The dinger in solar generation is the amount of sunlight which the solar cells absorb. Various types of solar trackers, which rotate themselves in order to make the solar cells face the sun as much as possible, have been developed, and especially the method of tracking with two axes has greatly contributed in increasing the generation amount at work sites. Among theses 2-axis solar trackers, the inclination-dependent 2-axis solar tracker are widely utilized for its advantages of requiring less initial investment and easy maintenance due to a solid structure. However, the drawback is that the generation efficiency is relatively low because of the structural restriction that limits the rotation angle, thus making it less efficient when tracking the sun. This paper proposes a method to increase the generation efficiency of the inclination-dependent 2-axis solar tracker. It also contains the derived equations needed for precise controlling along with a method to keep tracking with the other axis even when one has reached its angle limit. To confirm that the proposed method increases the amount of incidence onto the solar cells, formulas needed for operation on the proposed method and tracking the exact position of the sun are derived, and applying this to the quarterly data of Korea Astronomy and Space Science Institute it shows maximum over 11.1% more incidence compared to existing methods.

Quantified Evaluation on the Qualitative Criteria for the Selection of Appropriate Concrete Slab Form-works for Residential Buildings (델파이 기법을 이용한 정성적 공법 선정 요인의 정량적 평가 분석)

  • Lee, Kyung-Suk;Lee, Tae-Hee;Shin, Young-Keun;Kim, Tae-Hyung;Han, Seung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.136-144
    • /
    • 2011
  • The form-work operation of concrete structures is a major element determining the period and cost of construction projects. However, the selection of the appropriate form-work system is dependent on the experience of the site personnel only. In this paper, existing methods (Aluminum form, Sky deck) and new slab form-work methods (AFB: Aluminum panel Form with dropping Beam) were selected. Each method was estimated by means of Delphi techniques based on the qualitative analysis data. This paper suggests an evaluation methodology of slab form-work application in construction sites by calculating qualitative evaluation scores. The methodology finding quantified scores of qualitative criteria can be available to be applied to other construction operation evaluation methods.

A Study on Cable Lifetime Evaluation Based on Characteristic Analysis of Insulation Resistance by Acceleration Factor of the Arrhenius Equation (아레니우스 방정식의 가속인자를 만족하는 절연저항특성 분석에 의한 케이블 수명평가 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.231-236
    • /
    • 2014
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. In this paper, in order to determine a stable operation of high-voltage power cable, used as a unique means of delivering electric power generated at a power station, we figure out the time rate of change of insulation resistance following a decay accelerating factor Arrhenius equation. With the data from the insulation resistance, we can determine the lifetime of power cable in operation.

Dynamic characteristic change of a PSC girder due to fatigue (피로에 따른 PSC거더의 동적특성 변화)

  • Choi, Sang-Hyun;Lee, Chang-Soo;Shin, Ki-Hoon;Kim, Tae-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1533-1538
    • /
    • 2011
  • The dynamic characteristics such as resonant frequencies and dampings have been utilized as important parameters in dynamic behavior and inverse analyses. In general, the dynamic parameters have been determined based on design and experimental data, but experimental studies on the time-dependent changes of the dynamic parameters during service have rarely been conducted. Especially, unlike highway bridges, it is much easier for railroad bridges to estimate accumulated amount of fatigue because of the controlled train operation, and the study of dynamic characteristic change due to fatigue is useful, since it can enhance the accuracy of dynamic analysis. In this paper, the dynamic characteristic change due to fatigue is measured via the modal test on the PSC girder during a fatigue test. The test specimen utilized in the test is the IT girder which enhances the sectional capacity of the conventional PSC girders. The test specimen is designed 10m long and the modal tests are conducted during the application of fatigue load two million times. The test result shows that considerable changes in the measured dynamic parameters are observed as the fatigue accumulates, and these changes during the service life should be considered in designing railroad bridges.

  • PDF

Optimization of Transportation Problem in Dynamic Logistics Network

  • Chung, Ji-Bok;Choi, Byung-Cheon
    • Journal of Distribution Science
    • /
    • v.14 no.2
    • /
    • pp.41-45
    • /
    • 2016
  • Purpose - Finding an optimal path is an essential component for the design and operation of smart transportation or logistics network. Many applications in navigation system assume that travel time of each link is fixed and same. However, in practice, the travel time of each link changes over time. In this paper, we introduce a new transportation problem to find a latest departing time and delivery path between the two nodes, while not violating the appointed time at the destination node. Research design, data, and methodology - To solve the problem, we suggest a mathematical model based on network optimization theory and a backward search method to find an optimal solution. Results - First, we introduce a dynamic transportation problem which is different with traditional shortest path or minimum cost path. Second, we propose an algorithm solution based on backward search to solve the problem in a large-sized network. Conclusions - We proposed a new transportation problem which is different with traditional shortest path or minimum cost path. We analyzed the problem under the conditions that travel time is changing, and proposed an algorithm to solve them. Extending our models for visiting two or more destinations is one of the further research topics.

Characteristic Analysis of Power Compensation Condenser Considering Voltage Harmonics (전압 고조파를 고려한 역률보상용 콘덴서의 특성 분석)

  • Kim, Jong-Gyeum;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.141-145
    • /
    • 2010
  • Most of the industrial loads includes the non-linear load as well as the linear load because there are many kinds of power conversion equipments at the input stage of the load in distribution network. The non-linear load causes the distortion of voltage waveform at PCC because the non-linear load generates the harmonic current. As a result, various voltage harmonics are existed at PCC depending on the current harmonics from the non-linear load. And, a series reactor is generally connected to the power capacitor in series to attenuate the distortion of voltage waveform and to reduce an inrush current of power capacitor. Also, harmonic current of power capacitor is highly dependent on the series reactor because it is operated with the power capacitor as a passive filter against nonlinear loads. Then, these capacitors might be damaged by the excessive voltage and current harmonic components. In this paper, we presented how to select the capacitor and series reactor to meet the requirement of the voltage distortion at PCC and analyzed the voltage, current and capacity rating of the power capacitor by the computer simulation to ensure the safe operation of power capacitor when the voltage harmonics at PCC are existed. Also, the analysis data were compared with the experimental measurements for the verification.

Factors Affecting on Organizational Commitment of Hospital Physical Therapists (병원에 근무하는 물리치료사의 직장애착에 영향을 미치는 요인)

  • Choi, Man-Kyu;Lee, Suk-Min
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.503-512
    • /
    • 2000
  • This study was carried out to find out factors affecting on organizational commitment of hospital physical therapists in Korea. The sample used in this study consisted of 135 physical therapists who were working in hospitals located in Seoul. The data for analysis were collected by questionnaire survey. The major statistical methods used for the analysis were factor analysis and multiple regression analysis. The dependent variable of the study was organizational commitment (responsibility of organization and propensity to stay), and the independent variables were general characteristic of respondents and components of job satisfaction - "task", "organizational operation system", "opportunity of development", "interpersonal relationship" - of hospital physical therapists. Important factors affecting the responsibility of organizational commitment were religion, work period, task satisfaction, opportunity of development. And propensity to stay was significantly affected by religion, work period, and four components of job satisfaction. In considering above findings, for improving factors affecting on organizational commitment of physical therapists, hospitals need to develop strategies for enhancing job satisfaction by providing the adequate job environment.

  • PDF