• 제목/요약/키워드: Data rate control

검색결과 2,942건 처리시간 0.03초

CTC와 SCADA간 정보전송 프로토콜에 대한 프레임 에러율 분석 (Analysis for Frame Error Rate of a Data Transmission Protocol between CTC and SCADA)

  • 강문호;이재호;황종규;박영수
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.296-301
    • /
    • 2004
  • This paper addresses an analysis for a railway data transmission protocol-Ethernet based data transmission between the CTC(Centralized Traffic Control System) and the SCADA(Supervisory Control and Data Acquisition) system. Fame error rates of the data transmissions are calculated and compared for the two cases that the CTC/SCADA has an extra data transmission error control(CRCI6) besides the inherent error control of the Ethernet(CRC32), and that the CTC/SCADA has no extra data transmission error control. With simulation results it has been verified that the extra data transmission error control(CRC16) contributes to lowering the frame error rate.

적응형 어레이 안테나 시스템에서의 호 수락제어 알고리즘 성능 개선에 관한 연구 (Performance Enhancement of Call Admission Control in an Adaptive Array Antenna System)

  • 김민정;김낙명
    • 한국통신학회논문지
    • /
    • 제29권9A호
    • /
    • pp.1013-1021
    • /
    • 2004
  • WCDMA 방식 이동 멀티미디어 시스댐어써 고속 데이터 λ냉자에 의한 간섭은 시스템의 용량과 성능을 저하 시키는 주요 요인이 되며, 적응형 안테나 시스템을 도입하여 고속 데이터 사용자의 간성을 크게 줄여줌으로써 시스템의 성능을 향상시킬 수 있다 이 경우, 적용형 안테나의 효과를 극대화하기 위한 방법으로서, 호 수락제어 기법의 최적화가 중요하고 생간 핸드요프 과정에 있어서의 효율적인 제어 방식이 중요한 논제가 된다. 본 논문에서 는 핸드요프 되는 고속의 데이터들을 효과적으로 처리하기 위하여 Soft QoS 를 적용한 호 수락 제어 알고리즘을 제안하고, 전송 속도에 따른 적응형 핸드요프 제어 방식을 제안하였다 제안된 알고리듬을 적용함으로써, 적응형 안테나 시스템의 고속 데이터 전송을 효과적으로 수행하연서도 셀 내 저속 가업자의 호 블록킹 확률을 크게 줄일 수 있음을 컴퓨터 시뮬레이션을 통한 비교분석으로 입증하였다.

무선 센서 네트워크에서 혼잡 패턴을 고려한 전송률 조절 기법 (A Rate Control Scheme Considering Congestion Patterns in Wireless Sensor Networks)

  • 강경현;정광수
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제16권12호
    • /
    • pp.1229-1233
    • /
    • 2010
  • 이벤트 기반 무선 센서 네트워크에서 주기적인 센싱 데이터에 비해 높은 전송률과 우선순위를 갖는 이벤트 데이터가 병목 구간에 집중되면 네트워크 혼잡이 발생한다. 혼잡이 지속되면 대부분의 데이터가 손실되는 네트워크 붕괴 현상이 나타난다. 전송률 조절 기법은 이러한 네트워크 붕괴 현상을 막기 위한 해결책 중 하나이다. 본 논문에서는 무선 센서 네트워크에서의 혼잡 제어를 위해 각 노드에서 혼잡 패턴에 따라 자식 노드의 전송률을 조절하는 기법을 제안한다. 실험을 통해 제안하는 기법이 효과적으로 혼잡을 제어하고, 기존의 전송률 조절 기법들보다 더 많은 이벤트 데이터를 전송함을 확인하였다.

무선센서 네트워크에서 주기적 메시지에 대해 신뢰성 있는 메시지 전송을 위한 라우팅 프로토콜 (Reliable Message Routing Protocol for Periodic Messages on Wireless Sensor Networks)

  • 호아이 퐁;김명균
    • 제어로봇시스템학회논문지
    • /
    • 제17권2호
    • /
    • pp.190-197
    • /
    • 2011
  • In industrial distributed control systems, sensors collect data from the physical environment periodically and transmit them to the actuators, which process the control operations based on the received data. For the effective operation of the control systems, the data transmitted by the sensors has to be delivered to the actuators reliably within the deadline, and if the message reception rate of the actuators becomes lower than a threshold, then the performance of the control systems drops greatly. This paper suggests a message routing protocol to transmit periodic messages reliably in a distributed control system based on wireless sensor networks. For reliable message transmission, the proposed protocol selects a routing path whose end-to-end message reception rate is the highest before transmitting data messages. The proposed protocol has the capability of maintaining a target message reception rate for each flow. To maintain the required target reception rate, each destination monitors the actual message reception rate periodically and transmits a feedback message to the source if it drops below the target reception rate. On receiving the feedback message, the source tries to find a new path which can satisfy the target rate. The performance of the proposed protocol has been evaluated using simulation and compared with other protocols in terms of the message reception rate, the message delay and delay jitter, and so on. The simulation results show that the proposed protocol has a higher message reception rate and comparable message delay and delay jitter to other protocols. The simulation results also show that the proposed protocol has an ability to adapt well to the dynamic network traffic change.

CDMA2000 1x 시스템을 위한 송신전력기반 전송률 제어방안 (Transmitted Power Based Dynamic Rate Control for CDMA2000 1x System)

  • 박형근
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권8호
    • /
    • pp.498-500
    • /
    • 2005
  • In a CDMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power The capacity of CDMA2000 1x system is considered to be limited by the forward link capacity Different rate data traffic requires different transmitted power and rate controlling enables the system utilize radio resource more efficiently. A very simple rate control algorithm for data calls in CDMA2000 1x system is proposed. In the proposed algorithm, by monitoring the total transmit power, we can simply adjust data rate to channel conditions and efficiently use radio resources. The proposed algorithm is easy to implement in power controlled CDMA systems.

CDMA2000 1x 시스템을 위한 송신전력기반 전송률 제어방안 (Transmitted power based dynamic rate control for CDMA2000 1x system)

  • 박형근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.221-223
    • /
    • 2005
  • In a CDMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power. The capacity of CDMA2000 1x system is considered to be limited by the forward link capacity. Different rate data traffic requires different transmitted power and rate controlling enables the system utilize radio resource more efficiently. A very simple rate control algorithm fer data calls in CDMA2000 1x system is proposed. In the proposed algorithm, by monitoring the total transmit power, we can simply adjust data rate to channel conditions and efficiently use radio resources. The proposed algorithm is easy to implement in power controlled CDMA systems.

  • PDF

Control Charts for Constant Failure Rate of System

  • 조교영;이옥희
    • Journal of the Korean Data and Information Science Society
    • /
    • 제13권2호
    • /
    • pp.147-156
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement(with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

Comparisons of Control Charts for Failure Rate with Fixed Inspection Interval

  • Lee, Jae-Man;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제15권4호
    • /
    • pp.793-801
    • /
    • 2004
  • In this paper, we propose control charts for failure rate using the number of failures based on the fixed interval inspection with replacement. And we investigate the power of detection of the proposed control charts by the ARL.

  • PDF

네트워크 트래픽 상태에 적응적인 UDT Rate Control 기법 (An Adaptive UDT Rate Control Method on Network Traffic Condition)

  • 안도식;왕기철;김승해;조기환
    • 대한전자공학회논문지TC
    • /
    • 제48권3호
    • /
    • pp.19-27
    • /
    • 2011
  • 광 네트워크 기술의 발달로 인해 오늘날 대부분의 네트워크는 수십 Gb/s를 지원한다. UDT(UDP-based Data Transfer protocol)는 대역폭과 지연시간이 큰 네트워크 환경에서 대용량 데이터 전송을 위한 프로토콜이다. 그러나 UDT는 고정된 sync-interval(0.01초) 간격으로 주기적인 rate control을 실행한다. 네트워크 트래픽 상태의 변화가 심한 환경에서는 sync-interval 동안 가용 대역폭을 충분히 활용하지 못하는 문제점이 발생한다. 본 논문은 sync-interval 구간에서 네트워크 트래픽 상태에 적응적인 rate control 기법을 제안한다. 네트워크 트래픽 상태는 RTT 변화를 바탕으로 판단한다. 제안 기법은 네트워크 상태를 4개의 구간으로 설정하여 패킷 sending period를 조절함으로써 rate control을 수행한다. 시뮬레이션 결과를 통하여 기존 UDT에 비해 throughput 과 안정성이 향상되었음을 보였다.