• 제목/요약/키워드: Data flow analysis

검색결과 4,104건 처리시간 0.04초

박리유동장에서 저속 익형의 공기역학적 성능해석 (An Aerodynamic Performance Analysis of the Low-Speed Airfoils in Seperated Flow Field)

  • 유능수
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.153-168
    • /
    • 1995
  • The purpose of this study is to develop a method for predicting the aerodynamic performance of the subsonic airfoils in the 2-dimensional, steady and viscous flow. For this study, the airfoil geometry is specified by adopting the longest chord line system and by considering local surface curvature. In case of the inviscid-incompressible flow, the analysis is accomplished by the linearly varying strength vortex panel method and the Karman-Tsien correction law is applied for the inviscid-compressible flow analysis. The Goradia's integral method and the Truckenbrodt integral method are adopted for the boundary layer analysis of the laminar flow and the turbulent flow respectively. Viscous and inviscid solutions are converged by the Lockheed iterative calculating method using the equivalent airfoil geometry. And the analysis of the seperated flow is performed using the Dvorak and Maskew's method as the basic method. The wake effect is also considered and its geometry expressed by the formula of Summey & Smith when no seperation occurs. A computational efficiency is verified by the comparison of the computational results with experimental data and by the shorter execution time.

  • PDF

객체지향 데이터베이스를 이용한 전력계통 해석 (Power System Analysis using OODB)

  • 박지호;백용식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.257-265
    • /
    • 2004
  • The complex documentation involved in power system analysis software require a well-defined and friendly database system. We have developed an object-oriented database management system for power system analysis, and have described load flow analysis and transient stability analysis using object-oriented database(OODB). Database management systems are widely used and achieve high reliability of data management in the engineering fields. However relational database system have shortcomings in application to power system analysis. ill relational database, the data model is too simple for modeling complex data and database languages are very different from programming languages. Object-oriented techniques are sufficiently powerful to support data-modeling requirements of GUI applications. The GUI is implemented using C++ on a MS windows platform. The OODB supports data modeling requirements of GUI applications and the performance is well acceptable for Gill applications.

튜플 코드 상에서의 최적화기 구현과 분석 (Implementation and Analysis of Optimizers on Tuple codes)

  • 송진국
    • 한국정보통신학회논문지
    • /
    • 제3권4호
    • /
    • pp.723-736
    • /
    • 1999
  • 컴파일러의 코드 최적화(code optimization)는 생성되는 기계 코드의 실행 시간을 감소시키고 기억장소 크기를 감소시키기 때문에 매우 중요한 단계이다. 본 연구에서는 튜플(tuple) 형태의 중간코드에서 제어 및 자료 흐름 분석(control and data flow analysis)을 수행하여 프로그램의 흐름 분석 정보를 얻어 각종 최적화를 수행하는 최적화기(optimizer)를 구현하였다. 또한, 각 최적화기들이 수행한 최적화 정도를 비교 분석하고 최적화기들 상호간의 의존성을 분석하였다. 따라서, 컴파일러 최적화 단계에서 우선적으로 수행할 최적화기를 선택 문제를 해결하구 상호간의 의존도로부터 최적화들간의 순서를 정할 수 있다.

  • PDF

전력조류계산을 위한 학습용GUI에 관한 연구 (A Study on the Learning GUI for the Load Flow of Power System)

  • 이희영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.27-29
    • /
    • 2004
  • This paper presents improved teaching and learning Gill for easily analysis tool of load flow of power system. This GUI includes not only contingency analysis function, but also calculating power loss from transmission line flow. The Gill is friendly for study for power system operation and control because picture provide a better visualizing of relationships between input parameters and effect than a tabula type result. This Gill enables topology and the output data of load flow for line outages to be shown on same picture page. Users can input the system data for power flow on the the picture and can easily see the the result diagram of bus voltage, bus power, line flow. It is also observe the effects of different types of variation of tap, shunt capacitor, loads level, line outages. Proposed Gill has been studied on the Ward-Hale 6-Bus system.

  • PDF

Switched Shunt의 무효전력 민감도를 이용한 조류계산 수렴성 개선 (Improvement of the Power Flow Convergency Using Switched Shunt Reactive Power Sensitivity)

  • 오성균;양민욱;김건중
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.355-360
    • /
    • 2012
  • It is difficult to converge power flow for the power system planning data. The main cause of power flow diverse is reactive power imbalance. A active power could be adjust by ELD or merit order but a reactive power couldn't dispatch before power flow analysis. The lack of reactive power of power system is cause a inadequate voltage drop This paper suggest new reactive power dispatch algorithm using switched shunt admittance. This algorithm uses reactive power sensitivity called switch shunt jacobian. When proposed algorithm applies to real system data that couldn't be conversed in PSS/E the power flow analysis is converged.

전동기 냉각팬의 유량예측을 위한 수치해석 (A Numerical Analysis for Prediction of Flow Rate of the Motor Cooling Fan)

  • 이상환;강태인;안철오;서인수;이창준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.670-677
    • /
    • 2005
  • In this study, we analyzed the three dimensional unsteady flow field around the motor cooling fan using the unsteady lifting surface theory. We obtained the flow rate for various geometries of fan from the calculated results of velocity field. For the data of design parameter and rotating speed(rpm) of the fan, we can predict the flow rate of the motor cooling fan with thin thickness through numerical analysis without the experimental data of the free stream velocity which is a boundary condition of flow field. the numerical results showed the flow rate within 10% of error in comparison with experimental results. The radial fans, which are often used as internal motor fan were also investigated with the same procedure.

  • PDF

시로코팬의 3차원 유동 특성 및 성능에 대한 전산해석 (Computational Analysis of the Three-Dimensional Flow Characteristics and the Performance of Sirocco Fan)

  • 하재홍;문영준
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.674-679
    • /
    • 2000
  • The Sirocco fan performance and its three-dimensional flow characteristics were numerically predicted by STAR-CD software. Turbulent flow computations were performed using approximately 500,000 mesh points, and the performance results of two computational methods, transient analysis and quasi-static analysis were compared with experimental data. At present, our attention was focused on localizing the three-dimensional flow characteristics of the Sirocco fin, especially the structure of the secondary flow in the scroll and the through-flow characteristics of the Sirocco fan blades. Also, for an optimization, the scroll passage was tilted with 10 degrees to change the flow characteristics and improve the performance of the Sirocco fan.

  • PDF

배전자동화 시스템의 단말장치(FRTU)로부터 취득되는 데이터를 이용한 방사상 배전계통 조류계산 방법에 관한 연구 (A Study on Power Flow Method of Radial Distribution System using a measured data from FRTU in Distribution Automation System)

  • 김형승;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.286-287
    • /
    • 2015
  • Currently, Studies on improving the reliability of power supply is becoming an important issue because of the increase in demand of the electric power system. Therefore necessity of automation in distribution system is increasing day by day. However, a measured voltage data from FRTU of distribution automation system is incorrect because of installation space limits. Therefore there is a need of system analysis method by considering the characteristics of the distribution system. For a distribution system, applying the power flow method of transmission system has some problems, as distribution is radial system and it has unbalanced load. Therefore power flow by considering the characteristics of the distribution system have been studied. Existing power flow analysis of the distribution system has different methods like direct analysis method, backward/forward sweep method, modified method of newton raphson etc. In this paper, an improved power flow analysis method based on backward/forward sweep method is proposed in order to efficiently operate the distribution automation system. The proposed method of power flow has been verified through the result of case study.

  • PDF

다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석 (Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP)

  • 지주연;박승용;이광우;박경민;황순홍;김동호;이영준
    • 한국환경과학회지
    • /
    • 제22권2호
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

드론을 활용한 연속류 교통정보 수집·분석에 관한 연구 (A Study on Traffic Data Collection and Analysis for Uninterrupted Flow using Drones)

  • 서성혁;이시복
    • 한국ITS학회 논문지
    • /
    • 제17권6호
    • /
    • pp.144-152
    • /
    • 2018
  • 본 연구는 기존 교통정보 수집체계의 한계를 보완하기 위한 수단으로써 드론을 사용하였을 경우 교통량, 속도, 밀도 등의 정보를 단시간에 경제적으로 수집 가능하다는 점에 착안하였으며, 이를 위해 드론을 실제 교통현장 촬영영상 분석을 통해 추출된 핵심 교통정보의 타당성 검증과 더불어 다양한 정보수집시나리오 분석을 통해 최적의 교통정보 추출 방법론을 제시하고자 하였다. 본 연구 수행결과, 드론은 단시간에 경제적인 교통정보수집이 가능한 유용한 정보수집 보완수단임은 물론, 매우 간단하고 직관적인 방법으로 연속류 구간의 서비스수준 판정을 가능하게 해 주는 강점이 있는 것으로 확인되었다.