• 제목/요약/키워드: Data error rate

검색결과 1,996건 처리시간 0.028초

Bootstrap confidence intervals for classification error rate in circular models when a block of observations is missing

  • Chung, Hie-Choon;Han, Chien-Pai
    • Journal of the Korean Data and Information Science Society
    • /
    • 제20권4호
    • /
    • pp.757-764
    • /
    • 2009
  • In discriminant analysis, we consider a special pattern which contains a block of missing observations. We assume that the two populations are equally likely and the costs of misclassification are equal. In this situation, we consider the bootstrap confidence intervals of the error rate in the circular models when the covariance matrices are equal and not equal.

  • PDF

확장 칼만필터를 이용한 홀로그래픽 에러 보정 알고리즘 (Generation of Error corrector for Holographic Data Storage system Used The Extended Kalman filter)

  • 김장현;양현석;박진배;박영필
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.44-46
    • /
    • 2005
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time. Today any data storage system cannot satisfy these conditions, however holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System can be constructed without mechanical actuating part therefore fast data transfer rate and high storage capacity about $1Tb/cm^3$ can be realized. In this paper, to reduce errors of binary data stored in holographic data storage system, a new method for bit error reduction is suggested. We proposal Algorithm use The Extended Kalman filter. The Kalman filter reduce measurement noise. Therefore, By using this error reduction method following results are obtained; the effect of measurement nois of Pixel is decreased and the intensity profile of data page becomes uniform therefore the better data storage system can be constructed.

  • PDF

근접 픽셀 에러 감소를 위한 홀로그래픽 데이터 스토리지 시스템의 퍼지 규칙 생성 (Design error corrector of binary data in holographic dnta storage system using fuzzy rules)

  • 김장현;김상훈;양현석;박진배;박영필
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.129-133
    • /
    • 2005
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time. Today any data storage system cannot satisfy these conditions, however holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System can be constructed without mechanical actuating part therefore fast data transfer rate and high storage capacity about $1Tb/cm^3$ can be realized. In this paper, to reduce errors of binary data stored in holographic data storage system, a new method for bit error reduction is suggested. First, find cluster centers using subtractive clustering algorithm then reduce intensities of pixels around cluster centers and fuzzy rules. Therefore, By using this error reduction method following results are obtained ; the effect of Inter Pixel Interference noise is decreased and the intensity profile of data page becomes uniform therefore the better data storage system can be constructed.

  • PDF

유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안 (The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data)

  • 김윤하;최현주
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

디지털 홀로그래픽 데이터 저장 시스템을 위한 1차원 및 2차원 최소 평균-제곱-에러 등화에 관한 연구 (A study on 1 & 2 dimensional minimum mean-squared-error equalization for digital holographic data storage system)

  • 최안식;전영식;정종래;백운식
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.486-492
    • /
    • 2002
  • 본 논문에서는 디지털 홀로그래픽 데이터 저장 시스템에서 2차원 데이터의 저장과 복원 동안에 발생되는 상호 픽셀에 의한 간섭(intersymbol interference:ISI)을 완화하고 bit-error-rate(BER) 성능개선을 위해 1차원 및 2차원 최소 평균-제곱-에러 (minimum mean-squared-error:MMSE) 등화(equalization)를 적용하였다. 홀로그래픽 저장 시스템으로부터 복원된 10개의 페이지에 대해서 등화 수행전보다 1차원 및 2차원 MMSE등화 적용 후, BER과 signal-to-noise ratio(SNR)이 향상됨을 보였다.

저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향 (The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy)

  • 박영상;손병진;손재범;이호열;정유수;송찬호;정의성
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권6호
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

가변속 냉동사이클의 강인제어를 위한 퍼지로직의 멤버십함수 범위 설계 (Design of Membership Ranges for Robust Control of Variable Speed Drive Refrigeration Cycle Based on Fuzzy Logic)

  • 정석권
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.18-24
    • /
    • 2018
  • This paper focuses on systematic design about the membership ranges of the main design factors such as control error, control error rate, and sampling time for the fuzzy logic control of the variable speed drive refrigeration cycle. The upper and the lowest limit of the membership ranges are set up from the data of static characteristics obtained by experiments. Three kinds of membership ranges on the control error and the control error rate are tested by experiments. Especially, an effect of sampling time on control performance is also investigated in the same way. Experimental data showed the control error rate and the sampling time strongly effected on the control performance of the refrigeration cycle with a variable speed drive.

이중 버퍼 제어기 구조의 터보 복호기를 사용한 전송률 가변 비대칭 TDD 시스템 설계 (Design of Variable Data Transfer Rate Asymmetric TDD System Using Turbo Decoder with Double Buffer Controller)

  • 박병관;김미래;김효종
    • 한국항공우주학회지
    • /
    • 제47권2호
    • /
    • pp.161-168
    • /
    • 2019
  • 본 논문에서는 소형 무인기 데이터 링크 시스템에 적용이 가능한 전송률 가변 비대칭 TDD(Time Division Duplex) 방식에 대해 다루었다. 긴 복호 시간이 필요한 터보 복호기를 비대칭 TDD 방식에 적용하기 위하여 이중 버퍼 제어기 구조의 터보 복호기를 제안하였다. 제안 방법은 전송률 가변과 동일 송수신 시간에 최대의 데이터 전송이 가능하다. 제안 방식을 적용한 데이터 링크 시스템을 제작하여 성능을 확인하였다. 측정 결과, 대칭 TDD 방식에 비해 전송률은 최대 약 1.8배 증가하였다. PER(Packet Error Rate) 성능은 동일하며, 전송률 가변이 가능함을 확인하였다.

Cold Data Identification using Raw Bit Error Rate in Wear Leveling for NAND Flash Memory

  • Hwang, Sang-Ho;Kwak, Jong Wook;Park, Chang-Hyeon
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권12호
    • /
    • pp.1-8
    • /
    • 2015
  • Wear leveling techniques have been studied to prolong the lifetime of NAND flash memory. Most of studies have used Program/Erase(P/E) cycles as wear index for wear leveling. Unfortunately, P/E cycles could not predict the real lifetime of NAND flash blocks. Therefore, these algorithms have the limited performance from prolonging the lifetime when applied to the SSD. In order to apply the real lifetime, wear leveling algorithms, which use raw Bit Error Rate(rBER) as wear index, have been studied in recent years. In this paper, we propose CrEWL(Cold data identification using raw Bit error rate in Wear Leveling), which uses rBER as wear index to apply to the real lifetime. The proposed wear leveling reduces an overhead of garbage collections by using HBSQ(Hot Block Sequence Queue) which identifies hot data. In order to reduce overhead of wear leveling, CrEWL does not perform wear leveling until rBER of the some blocks reaches a threshold value. We evaluate CrEWL in comparison with the previous studies under the traces having the different Hot/Cold rate, and the experimental results show that our wear leveling technique can reduce the overhead up to 41% and prolong the lifetime up to 72% compared with previous wear leveling techniques.

심박수 측정을 위한 안면 얼굴 영상 데이터 수집 시스템 설계 (Design of Facial Image Data Collection System for Heart Rate Measurement)

  • 장승주
    • 한국정보통신학회논문지
    • /
    • 제25권7호
    • /
    • pp.971-976
    • /
    • 2021
  • 본 논문은 심박수 측정을 위한 안면 얼굴 영상 데이터 수집 시스템을 설계한다. 본 논문의 설계 내용은 웹 카메라를 이용하여 사용자 얼굴 영상 정보들을 수집하고, 수집된 사용자 얼굴 영상 정보들을 이용하여 심박수를 측정하는 기능이다. 웹 카메라를 이용한 비접촉식 심박수 측정으로 인하여 오차가 발생할 가능성이 있다. 따라서 본 논문에서는 심박수 측정시 얼굴 영상 데이터 분류를 통해서 오차가 발생한 경우와 정상적인 경우를 구별하여 심박수 프로그램 오차 수정에 이용할 수 있도록 하고자 한다. 오차가 발생된 경우의 자료를 이용하여 오차를 줄이기 위한 목적으로 사용할 수 있도록 한다. 본 논문에서 제안하고 설계한 내용에 대해서 실험을 수행하였다. 실험 결과 본 논문에서 설계한 내용이 정상적으로 동작됨을 확인할 수 있었다.