• Title/Summary/Keyword: Data Set Records

Search Result 197, Processing Time 0.023 seconds

A Design and Implementation of Health Schedule Application

  • Ji Woo Kim;Young Min Lee;Won Joo Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.99-106
    • /
    • 2024
  • In this paper, we design and implement the HealthSchedule app, which records exercise data based on the GPS sensor embedded in smartphones. This app utilizes the smartphone's GPS sensor to collect real-time location information of the user and displays the movement path to the designated destination. It records the user's actual path using latitude and longitude coordinates. Users register exercise activities and destination points when scheduling, and initiate the exercise. When measuring the current location, a lime green departure marker is generated, and the movement path is displayed in blue, with the destination marker and a surrounding 25-meter radius circle shown in sky blue. Using the coordinates of the starting point or the previous location and the current GPS sensor-transmitted location coordinates, it measures the distance traveled, time taken, and calculates the speed. Furthermore, it accumulates measurement data to provide information on the total distance traveled, movement path, and overall average speed. Even when reaching the destination during exercise, the movement path continues to accumulate until the completion button is clicked. The completion button is activated when the user moves into the sky blue circular area with a radius of 25 meters, centered around the initially set destination. This means that the user must reach the designated destination, and if they wish to continue exercising without clicking the completion button, they can do so. Depending on the selected exercise type, the app displays the calories burned, aiming to increase user engagement and a sense of accomplishment.

Incidence and Survival Rates among Pediatric Osteogenic Sarcoma Cases in Khon Kaen, Thailand, 1985-2010

  • Wiromrat, Pattara;Jetsrisuparb, Arunee;Komvilaisak, Patcharee;Sirichativapee, Winai;Kamsa-Ard, Supot;Wiangnon, Surapon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4281-4284
    • /
    • 2012
  • Background: Osteosarcoma is the most common bone cancer in children, responsible for a high rate of amputation and death. This is the first long-term, population-based, epidemiologic and survival study in Thailand. Objective: To study the incidence and survival rates of pediatric osteosarcoma in Khon Kaen. Method: Childhood osteosarcoma cases (0-19 years) diagnosed between 1985-2010 were reviewed. The data were retrieved from the population-based data set of the Khon Kaen Cancer Registry and medical records from Srinagarind Hospital, Faculty of Medicine, Khon Kaen University. All cases were censored until the end of April 2012. The age-standardized incidence rate (ASR) was calculated using the standard method. Survival experience was analyzed using the standard survival function (STATA 9.0) and presented with a Kaplan-Meier curve. Results: 58 cases were enrolled. The overall ASR was 14.1 per million. Males and females were equally affected. The peak incidence was for 15-19 year-olds in both sexes (ASR=10.4 per million in males and 8.5 in females). The 5-year overall survival rate was 27.6% (95% CI: 15.8-40.8%). The median survival time was 1.6 years (95% CI: 1.2-2.1). In a subgroup analysis, the patients who received only chemotherapy survived longer (5-year survival 45.7%, median survival time 4.1 years, p=0.12). Conclusion: The incidence rate for childhood osteosarcoma was slightly less than those reported for Western countries. The survival rate was also lower than reports from developed countries. Further evaluation of the treatment protocol and risk factor stratification is needed.

Implementation of a Vehicle Monitoring System using Multimodal Information (다중 정보를 활용하는 차량 모니터링 시스템의 구현)

  • Park, Su-Wan;Son, Jun-U
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.3
    • /
    • pp.41-48
    • /
    • 2011
  • In order to detect driver's state in a driver safety system, both overt and covert measures such as driving performance, visual attention, physiological arousal and traffic situation should be collected and interpreted in the driving context. In this paper, we suggest a vehicle monitoring system that provides multimodal information on a broad set of measures simultaneously collected from multiple domains including driver, vehicle and road environment using an elaborate timer equipped as a soft synchronization mechanism. Using a master timer that records key values from various modules with the same master time of short and precise interval, the monitoring system provides more accurate context awareness through synchronized data at any given time. This paper also discusses the data collected from nine young drivers performing a cognitive secondary task through this system while driving.

Implementation of a Black-Box Program Monitoring Abnormal Body Reactions (부정기적 발생 신체이상 모니터링 블랙박스 프로그램 구현)

  • Kim, Won-Jin;Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.671-677
    • /
    • 2012
  • A black-box program was implemented in order to monitor abnormal symptoms of human body irregularly occurring during sleep. The system consists of sensor probing body signals, auxiliary devices such as the alarm, lamp, network camera, and signal monitoring computer. Various types of sensors, PPG, ECG, EEG, temperature, respiration sensor, G-sensor, and microphone were used to more exactly identify the causes of abnormal symptoms. If a symptom occurs, the system records the patient's condition to provide information being utilized in the treatment. The sensors are attached on some locations of body being proper to check a specific type of abnormal reaction. Based on the normal range and type of measurement data, criteria of signal levels were set to distinguish abnormal reaction. An abnormal signal being probed, the program starts to operate the lamp, alarm, and network camera at the same time and stores the signal and video data.

A Multivariate Analysis of Korean Professional Players Salary (한국 프로스포츠 선수들의 연봉에 대한 다변량적 분석)

  • Song, Jong-Woo
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.3
    • /
    • pp.441-453
    • /
    • 2008
  • We analyzed Korean professional basketball and baseball players salary under the assumption that it depends on the personal records and contribution to the team in the previous year. We extensively used data visualization tools to check the relationship among the variables, to find outliers and to do model diagnostics. We used multiple linear regression and regression tree to fit the model and used cross-validation to find an optimal model. We check the relationship between variables carefully and chose a set of variables for the stepwise regression instead of using all variables. We found that points per game, number of assists, number of free throw successes, career are important variables for the basketball players. For the baseball pitchers, career, number of strike-outs per 9 innings, ERA, number of homeruns are important variables. For the baseball hitters, career, number of hits, FA are important variables.

Estimation of extreme sea levels at tide-dominated coastal zone (조석이 지배적인 해역의 극치해면 산정)

  • Kang, Ju Whan;Kim, Yang-Seon;Cho, Hongyeon;Shim, Jae-Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.6
    • /
    • pp.381-389
    • /
    • 2012
  • An EST-based method which is applicable for estimating extreme sea levels from short sea-level records in a tide dominated coastal zone was developed. Via the method, annual maximum tidal level is chosen from the simulated 1-yr tidal data which are constituted by the independent daily high water levels, short term and long term surge heights and typhoon-induced surge heights. The high water levels are generated considering not only spring/neap tides and annual tide but also 18.6-year lunar nodal cycle. Typhoon-induced surges are selected from the training set which is constructed by observed or simulated surge heights. This yearly simulation is repeated many hundred years to yield the extreme tidal levels, and the whole process is carried out many hundred times repeatedly to get robust statistics of the levels. In addition, validation of the method is also shown by comparing the result with other researches with the tidal data of Mokpo Harbor.

Estimation of Disease Code Accuracy of National Medical Insurance Data and the Related Factors (의료보험자료 상병기호의 정확도 추정 및 관련 특성 분석 -법정전염병을 중심으로-)

  • Shin, Eui-Chul;Park, Yong-Mun;Park, Yong-Gyu;Kim, Byung-Sung;Park, Ki-Dong;Meng, Kwang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.471-480
    • /
    • 1998
  • This study was undertaken in order to estimate the accuracy of disease code of the Korean National Medical Insurance Data and disease the characteristics related to the accuracy. To accomplish these objectives, 2,431 cases coded as notifiable acute communicable diseases (NACD) were randomly selected from 1994 National Medical Insurance data file and family medicine specialists reviewed the medical records to confirm the diagnostic accuracy and investigate the related factors. Major findings obtained from this study are as follows : 1. The accuracy rate of disease code of NACD in National Medical Insurance data was very low, 10.1% (95% C.I. : 8.8-11.4). 2. The reasons of inaccuracy in disease code were 1) claiming process related administrative error by physician and non-physician personnel in medical institutions (41.0%), 2) input error of claims data by key punchers of National Medical Insurer (31.3%) and 3) diagnostic error by physicians (21.7%). 3. Characteristics significantly related with lowering the accuracy of disease code were location and level of the medical institutions in multiple logistic regression analysis. Medical institutions in Seoul showed lower accuracy than those in Kyonngi, and so did general hospitals, hospitals and clinics than tertiary hospitals. Physician related characteristics significantly lowering disease code accuracy of insurance data were sex, age group and specialty. Male physicians showed significantly lower accuracy than female physicians; thirties and fortieg age group also showed significantly lower accuracy than twenties, and so did general physicians and other specialists than internal medicine/pediatric specialists. This study strongly suggests that a series of policies like 1) establishment of peer review organization of National Medical Insurance data, 2) prompt nation-wide expansion of computerized claiming network of National Medical Insurance and 3) establishment and distribution of objective diagnostic criteria to physicians are necessary to set up a national disease surveillance system utilizing National Medical Insurance claims data.

  • PDF

Development Process and Methods of Audit and Certification Toolkit for Trustworthy Digital Records Management Agency (신뢰성 있는 전자기록관리기관 감사인증도구 개발에 관한 연구)

  • Rieh, Hae-young;Kim, Ik-han;Yim, Jin-Hee;Shim, Sungbo;Jo, YoonSun;Kim, Hyojin;Woo, Hyunmin
    • The Korean Journal of Archival Studies
    • /
    • no.25
    • /
    • pp.3-46
    • /
    • 2010
  • Digital records management is one whole system in which many social and technical elements are interacting. To maintain the trustworthiness, the repository needs periodical audit and certification. Thus, individual electronic records management agency needs toolkit that can be used to self-evaluate their trustworthiness continuously, and self-assess their atmosphere and system to recognize deficiencies. The purpose of this study is development of self-certification toolkit for repositories, which synthesized and analysed such four international standard and best practices as OAIS Reference Model(ISO 14721), TRAC, DRAMBORA, and the assessment report conducted and published by TNA/UKDA, as well as MoRe2 and current national laws and standards. As this paper describes and demonstrate the development process and the framework of this self-certification toolkit, other electronic records management agencies could follow the process and develop their own toolkit reflecting their situation, and utilize the self-assessment results in-house. As a result of this research, 12 areas for assessment were set, which include (organizational) operation management, classification system and master data management, acquisition, registration and description, storage and preservation, disposal, services, providing finding aids, system management, access control and security, monitoring/audit trail/statistics, and risk management. In each 12 area, the process map or functional charts were drawn and business functions were analyzed, and 54 'evaluation criteria', consisted of main business functional unit in each area were drawn. Under each 'evaluation criteria', 208 'specific evaluation criteria', which supposed to be implementable, measurable, and provable for self-evaluation in each area, were drawn. The audit and certification toolkit developed by this research could be used by digital repositories to conduct periodical self-assessment of the organization, which would be used to supplement any found deficiencies and be used to reflect the organizational development strategy.

Cutoff Values for Diagnosing Hepatic Steatosis Using Contemporary MRI-Proton Density Fat Fraction Measuring Methods

  • Sohee Park;Jae Hyun Kwon;So Yeon Kim;Ji Hun Kang;Jung Il Chung;Jong Keon Jang;Hye Young Jang;Ju Hyun Shim;Seung Soo Lee;Kyoung Won Kim;Gi-Won Song
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1260-1268
    • /
    • 2022
  • Objective: To propose standardized MRI-proton density fat fraction (PDFF) cutoff values for diagnosing hepatic steatosis, evaluated using contemporary PDFF measuring methods in a large population of healthy adults, using histologic fat fraction (HFF) as the reference standard. Materials and Methods: A retrospective search of electronic medical records between 2015 and 2018 identified 1063 adult donor candidates for liver transplantation who had undergone liver MRI and liver biopsy within a 7-day interval. Patients with a history of liver disease or significant alcohol consumption were excluded. Chemical shift imaging-based MRI (CS-MRI) PDFF and high-speed T2-corrected multi-echo MR spectroscopy (HISTO-MRS) PDFF data were obtained. By temporal splitting, the total population was divided into development and validation sets. Receiver operating characteristic (ROC) analysis was performed to evaluate the diagnostic performance of the MRI-PDFF method. Two cutoff values with sensitivity > 90% and specificity > 90% were selected to rule-out and rule-in, respectively, hepatic steatosis with reference to HFF ≥ 5% in the development set. The diagnostic performance was assessed using the validation set. Results: Of 921 final participants (624 male; mean age ± standard deviation, 31.5 ± 9.0 years), the development and validation sets comprised 497 and 424 patients, respectively. In the development set, the areas under the ROC curve for diagnosing hepatic steatosis were 0.920 for CS-MRI-PDFF and 0.915 for HISTO-MRS-PDFF. For ruling-out hepatic steatosis, the CS-MRI-PDFF cutoff was 2.3% (sensitivity, 92.4%; specificity, 63.0%) and the HISTO-MRI-PDFF cutoff was 2.6% (sensitivity, 88.8%; specificity, 70.1%). For ruling-in hepatic steatosis, the CS-MRI-PDFF cutoff was 3.5% (sensitivity, 73.5%; specificity, 88.6%) and the HISTO-MRI-PDFF cutoff was 4.0% (sensitivity, 74.7%; specificity, 90.6%). Conclusion: In a large population of healthy adults, our study suggests diagnostic thresholds for ruling-out and ruling-in hepatic steatosis defined as HFF ≥ 5% by contemporary PDFF measurement methods.

3-Dimensional Performance Optimization Model of Snatch Weightlifting

  • Moon, Young-Jin;Darren, Stefanyshyn
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.157-165
    • /
    • 2015
  • Object : The goals of this research were to make Performance Enhanced Model(PE) taken the largest performance index (PI) through artificial variation of principle components calculated by principle component analysis for trial data, and to verify the effect through comparing kinematic factors between trial data (Raw) and PE. Method : Ten subjects (5 men, 5 women) were recruited and 80% of their maximal record was considered. The PI is a regression equation. In order to develop PE, we extracted Principle components from trial position data (by Principle Components Analysis (PCA)). Before PCA, we made 17 position data to 3 row matrix according to components. We calculated 3 eigen value (principle components) through PCA. And except Y (medial-lateral direction) component (because motion of Y component is small), principle components of X (anterior-posterior direction) and Z (vertical direction) components were changed as following. Changed principle components = principle components + principle components ${\times}$ k. After changing the each principle component, we reconstructed position data using the changed principle components and calculated performance index (PI). A Paired t-test was used to compare Raw data and Performance Enhanced Model data. The level of statistical significance was set at $p{\leq}0.05$. Result : The PI was significantly increased about 12.9kg at PE ($101.92{\pm}6.25$) when compared to the Raw data ($91.29{\pm}7.10$). It means that performance can be increased by optimizing 3D positions. The difference of kinematic factors as follows : the movement distance of the bar from start to lock out was significantly larger (about 1cm) for PE, the width of anterior-posterior bar position in full phase was significantly wider (about 1.3cm) for PE and the horizontal displacement toward the weightlifter after beginning of descent from maximal height was significantly greater (about 0.4cm) for PE. Additionally, the minimum knee angle in the 2-pull phase was significantly smaller (approximately 2.7cm) for the PE compared to that of the Raw. PE was decided at proximal position from the Raw (origin point (0,0)) of PC variation). Conclusion : PI was decided at proximal position from the Raw (origin point (0,0)) of PC variation). This means that Performance Enhanced Model was decided by similar motion to the Raw without a great change. Therefore, weightlifters could be accept Performance Enhanced Model easily, comfortably and without large stress. The Performance Enhance Model can provide training direction for athletes to improve their weightlifting records.