• Title/Summary/Keyword: Data Leaks

Search Result 123, Processing Time 0.025 seconds

A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection (가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구)

  • Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.369-374
    • /
    • 2021
  • Apartment recently built in kitchen is made is made because the gas hose with built-in ways invisible inside the sink. In this case, if the gas leaks, it is a dangerous method that can accumulate inside the sink and lead to an explosion. In this study, since the hose connected between the gas range and the intermediate valve is inside the sink, it is not possible to test for gas leaks, so a valve system that can easily check for gas leaks using a pressure sensor was studied. As for the pressure measurement method, the pressure of the hose connecting the intermediate valve and the gas range was measured so that data could be collected and analyzed using the I2C communication method. In addition, the calculation of the gas pressure supplied to the home was investigated for the atmospheric pressure error for the value calculated by adding the average value of the gas gauge pressure of 22.46 mbar at the inlet of the gas meter to the atmospheric pressure. A valve system was developed to detect minute gas leaks.

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

Using Continuous Flow Data to Predict the Course of Air Leaks After Lung Lobectomy

  • Jaeshin Yoon;Kwanyong Hyun;Sook Whan Sung
    • Journal of Chest Surgery
    • /
    • v.56 no.3
    • /
    • pp.179-185
    • /
    • 2023
  • Background: Assessments of air leaks are usually performed subjectively, precluding the use of air leaks as an evaluation factor. We aimed to identify objective parameters as predictive factors for prolonged air leak (PAL) and air leak cessation (ALC) from air flow data produced by a digital drainage system. Methods: Flow data records of 352 patients who underwent lung lobectomy were reviewed, and flow data at designated intervals (1, 2, and 3 hours postoperatively [POH] and 3 times a day thereafter [06:00, 13:00, 19:00]) were extracted. ALC was defined by flow less than 20 mL/min over 12 hours, and PAL was defined as ALC after 5 days. Cumulative incidence curves were obtained using Kaplan-Meier estimates of time to ALC. Cox regression analysis was performed to determine the effects of variables on the rate of ALC. Results: The incidence of PAL was 18.2% (64/352). Receiver operating characteristic curve analysis showed cut-off values of 180 mL/min for the flow at 3 POH and 73.3 mL/min for the flow on postoperative day 1; the sensitivity and specificity of these values were 88.9% and 82.5%, respectively. The rates of ALC by Kaplan-Meier analysis were 56.8% at 48 POH and 65.6% at 72 POH. Multivariate Cox regression analysis revealed that the flow at 3 POH (≤80 mL/min), operation time (≤220 minutes), and right middle lobectomy independently predicted ALC. Conclusion: Air flow measured by a digital drainage system is a useful predictor of PAL and ALC and may help optimize the hospital course.

Analysis of Pumping Performance of a Helical Drag Pump Using the Diffusion Equation (확산방정식을 이용한 헬리컬 드래그펌프의 성능해석)

  • Heo, Joong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.382-391
    • /
    • 2008
  • A simple analytical model of rarefied channel flow is developed to predict the compression ratio in a helical drag pump. If the surface velocity is zero, the model reduces to a capillary leaks. Predictions of our model agree well with the Knudsen's data for capillary leaks in transition flow, in addition to giving a good account of the Knudsen minimum. Also, the present results are compared with experimental data, and good agreement is obtained over the entire pressure range from molecular to slip flow.

Key Management Server Design for Providing Cryptographic Service in Cloud Computing Environment (Services in a Cloud Environment)

  • Jung, Ki Hyun;Shin, Seung Jung
    • International journal of advanced smart convergence
    • /
    • v.5 no.4
    • /
    • pp.26-31
    • /
    • 2016
  • In a cloud computing environment, a cryptographic service allows an information owner to encrypt the information and send it to a cloud server as well as to receive and decode encrypted data from the server which guarantees the confidentiality of shared information. However, if an attacker gains a coded data and has access to an encryption key via cloud server, then the server will be unable to prevent data leaks by a cloud service provider. In this paper, we proposed a key management server which does not allow an attacker to access to a coded key of the owners and prevents data leaks by a cloud service provider. A key management server provides a service where a server receives a coded public key of an information user from an owner and delivers a coded key to a user. Using a key management server proposed in this paper, we validated that the server can secure the confidentiality of an encryption key of data owners and efficiently distribute keys to data users.

Probabilistic Neural Network for Prediction of Leakage in Water Distribution Network (급배수관망 누수예측을 위한 확률신경망)

  • Ha, Sung-Ryong;Ryu, Youn-Hee;Park, Sang-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.799-811
    • /
    • 2006
  • As an alternative measure to replace reactive stance with proactive one, a risk based management scheme has been commonly applied to enhance public satisfaction on water service by providing a higher creditable solution to handle a rehabilitation problem of pipe having high potential risk of leaks. This study intended to examine the feasibility of a simulation model to predict a recurrence probability of pipe leaks. As a branch of the data mining technique, probabilistic neural network (PNN) algorithm was applied to infer the extent of leaking recurrence probability of water network. PNN model could classify the leaking level of each unit segment of the pipe network. Pipe material, diameter, C value, road width, pressure, installation age as input variable and 5 classes by pipe leaking probability as output variable were built in PNN model. The study results indicated that it is important to pay higher attention to the pipe segment with the leak record. By increase the hydraulic pipe pressure to meet the required water demand from each node, simulation results indicated that about 6.9% of total number of pipe would additionally be classified into higher class of recurrence risk than present as the reference year. Consequently, it was convinced that the application of PNN model incorporated with a data base management system of pipe network to manage municipal water distribution network could make a promise to enhance the management efficiency by providing the essential knowledge for decision making rehabilitation of network.

Analysis of Elastic Wave Based Leakage Detection Technology Using Accelerometers (가속도계를 이용한 탄성파 기반 누수탐지 기술 분석)

  • Choi, Kwangmook;Lee, Hohyun;Shin, Gangwook;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1231-1240
    • /
    • 2020
  • Water pipes are laid on the ground, making it impossible to visually detect leaks due to aging of pipes, and technology to detect leaks in pipes is mainly used to detect leaks in pipes by detecting leaks. In this paper, two accelerometers were attached to both ends of the constant water piping to calculate the time difference between the acquired data to detect leakage points. The leak test of piping was performed by installing valves at 4.3m, 8.6m, and 12.9m points on piping 17.2m, and changing the development rate of valves to 30% and 70%. Leakage can be detected for pressure drop in piping, which is 30% and 70% open valve. It is very important to detect leakage in the early stage, and it is judged that detection of the initial leak point from the algorithm applied in this paper will be possible.

A Study of Public Library Patrons' Understanding of Library Records and Data Privacy

  • Kim, Dong-Seok;Noh, Younghee
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.4 no.1
    • /
    • pp.53-78
    • /
    • 2014
  • As instances of private information leak increase, taking steps to protect such information becomes a necessity. In this study of public library patrons, we strove for a comprehensive understanding of library usage records to suggest viable solutions for private information safety in public libraries. To this end, we investigated the patrons' understanding of library usage records and determined the relationship between different user characteristics and privacy knowledge or leaks. The results show that a high number of patrons perceived these records as their own private information, but that there was no necessity for legal procedures or consent for the use of these records. Also, even though the understanding of these usage records showed that there was a relationship between the frequency of library visits and leaks of personal information, the correlation was not particularly strong.

Endoscopic vacuum therapy for treatment of spontaneous and iatrogenic upper gastrointestinal defects

  • Kavea Panneerselvam;Jake S. Jacob;Ronald E. Samuel;Andy Tau;Gyanprakash A. Ketwaroo;Wasif M. Abidi;Robert J. Sealock
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.754-760
    • /
    • 2023
  • Background/Aims: Endoscopic vacuum therapy (EVT) can heal a variety of defects within the gastrointestinal (GI) tract via applying negative pressure, which reduces the defect size, aspirates the infected fluid, and promotes granulation tissue. Here we present our experience with EVT as it relates to both spontaneous and iatrogenic upper GI tract perforations, leaks, and fistulas. Methods: This retrospective study was conducted at four large hospital centers. All patients who underwent EVT between June 2018 and March 2021 were included. Data on multiple variables were collected, including demographics, defect size and location, number and intervals of EVT exchanges, technical success, and hospital length of stay. Student t-test and the chi-squared test were used to analyze the data. Results: Twenty patients underwent EVT. The most common defect cause was spontaneous esophageal perforation (50%). The most common defect location was the distal esophagus (55%). The success rate was 80%. Seven patients were treated with EVT as the primary closure method. The mean number of exchanges was five with a mean interval of 4.3 days between exchanges. The mean length of hospital stay was 55.8 days. Conclusions: EVT is a safe and effective initial management option for esophageal leaks and perforations.

Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter (스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발)

  • Jung-Hoon Kim;Jung-Suk Oh;Jin-Han Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.57-64
    • /
    • 2023
  • As the meter reading method of gas meters develops, smart gas meters capable of remote meter reading (leak checking meters and multi-function safety meters) are being used. These meters have a function to judge leakage by utilizing the flow rate and pressure data collected as an additional function. Leakage judgment function using flow rate data has valid cases in the actual field, but the pressure data-based leakage judgment standard is based on not only the pressure value change due to leakage but also various factors (pressure regulator pressure, connection with adjacent meters, usage of adjacent houses, location of meters, etc.). There is a problem with pressure magnitude changes (levels). In this paper, as a technique that can judge leaks by using pressure data collected from smart gas meters, it was developed through preprocessing of pressure data, criteria for pressure value ranges related to leaks, leak judgment techniques, and application case verification.