• Title/Summary/Keyword: Data Leaks

Search Result 123, Processing Time 0.026 seconds

A Study on Security Container to Prevent Data Leaks (정보 유출 방지를 위한 보안 컨테이너의 효과성 연구)

  • Lee, Jong-Shik;Lee, Kyeong-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1225-1241
    • /
    • 2014
  • Recently, Financial companies implement DLP(Data Leaks Prevention) security products and enforce internal controls to prevent customer information leaks. Accidental data leaks in financial business increase more and more because internal controls are insufficient. Security officials and IT operation staffs struggle to plan countermeasures to respond to all kinds of accidental data leaks. It is difficult to prevent data leaks and to control information flow in business without research applications that handle business and privacy information. Therefore this paper describes business and privacy information flow on applications and how to plan and deploy security container based OS-level and Hypervisor virtualization technology to enforce internal controls for applications. After building security container, it was verified to implement internal controls and to prevent customer information leaks. With security policies additional security functions was implemented in security container and With recycling security container costs and time of response to security vulnerabilities was reduced.

Leak Detection in a Water Pipe Network Using the Principal Component Analysis (주성분 분석을 이용한 상수도 관망의 누수감지)

  • Park, Suwan;Ha, Jaehong;Kim, Kimin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.276-276
    • /
    • 2018
  • In this paper the potential of the Principle Component Analysis(PCA) technique that can be used to detect leaks in water pipe network blocks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study. The algorithms were designed to extract a partial set of flow data from the original 24 hour flow data so that the variability of the flows in the determined partial data set are minimal. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The results showed that the effectiveness of detecting leaks may improve by applying the developed algorithm. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks in real-world water pipe networks.

  • PDF

A Study on Industrial Technology Leakage and Effective Industrial Security Measures through analysis of domestic portal article data (국내 포털 기사자료 분석을 통한 산업기술유출 사례와 산업보안 강화 방안 연구)

  • Yang, Hyun Jung;Lee, Chang Moo
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.3-13
    • /
    • 2017
  • In the knowledge-information society, many domestic companies put lots of investment in technical development to possess core technologies and intellectual property. However, in the results of passive investment in security to protect their technologies compared to the active investment in technical development, the technology leaks from many companies and research institutes are rapidly increasing. Such increase of technology leaks not only causes damage to companies, but also has harmful effects on national economy directly and indirectly. Even though it has been perceived that a lot of industrial technology leak crimes are committed by former/current workers of small and medium-sized businesses, it is hard to find researches that mainly compare and analyze them. Therefore, this study aimed to understand the actual status of industrial technology leaks by analyzing cases of industrial technology leaks from 2014 to 2016 based on the type of victimized companies, corporate internal leakers' positions, matter of complicity, tools used for technology leaks, and motivation for technology leaks. Through the analysis in each type, the patterns and characteristics of industrial technology leaks were researched, and also the exploratory research on industrial security for the prevention of industrial technology leaks was conducted.

A Study on the Information Effluence State and Measure by Peer-to-Peer Programs in Korea and Japan (P2P프로그램을 통한 한국과 일본의 정보유출 현황 및 대책 연구)

  • Kim, Wan-Soo;Kim, Shik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.1
    • /
    • pp.67-74
    • /
    • 2009
  • Information Effluence leaks are caused by the wide use of the P2P program in Japan and Korea lead by the increase of internet use and network infrastructure expansion. This research confirms the seriousness of the data collected from the P2P leaks of the two countries and furthers its study by researching how countermeasures are applied. The effectiveness is verified by collecting data according to countermeasure applied periods. Both countries had information leaks, but in the case of Japan, not only personal information leaks but corporation, administrative agency, military, and others in a wide range as well. As a countermeasure against information effluence, Korea is enforcing counter plans mainly against the P2P service businesses and for Japan, various plans are taken such as business guides for each agency, organization management, SW development and supply, HW supply, and ect. The leaks in Japan were more severe than the ones in Korea but they had well planned countermeasures that were applied. Therefore if the Japanese countermeasure on information effluence of P2P programs is taken as a lesson, Korea can prevent the problem of leaks beforehand.

  • PDF

Endoscopic treatment of upper gastrointestinal postsurgical leaks: a narrative review

  • Renato Medas;Eduardo Rodrigues-Pinto
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.693-705
    • /
    • 2023
  • Upper gastrointestinal postsurgical leaks are life-threatening conditions with high mortality rates and are one of the most feared complications of surgery. Leaks are challenging to manage and often require radiological, endoscopic, or surgical intervention. Steady advancements in interventional endoscopy in recent decades have allowed the development of new endoscopic devices and techniques that provide a more effective and minimally invasive therapeutic option compared to surgery. Since there is no consensus regarding the most appropriate therapeutic approach for managing postsurgical leaks, this review aimed to summarize the best available current data. Our discussion specifically focuses on leak diagnosis, treatment aims, comparative endoscopic technique outcomes, and combined multimodality approach efficacy.

A Study on Insider Behavior Scoring System to Prevent Data Leaks

  • Lim, Young-Hwan;Hong, Jun-Suk;Kook, Kwang Ho;Park, Won-Hyung
    • Convergence Security Journal
    • /
    • v.15 no.5
    • /
    • pp.77-86
    • /
    • 2015
  • The organization shall minimize business risks associated with customer information leaks. Enhance information security activities through voluntary pre-check and must find a way to detect the personal information leakage caused by carelessness and neglect accident. Recently, many companies have introduced an information leakage prevention solution. However, there is a possibility of internal data leakage by the internal user who has permission to access the data. By this thread it is necessary to have the environment to analyze the habit and activity of the internal user. In this study, we use the SFI analytical technique that applies RFM model to evaluate the insider activity levels were carried out case studies is applied to the actual business.

Study on the applicability of the principal component analysis for detecting leaks in water pipe networks (상수관망의 누수감지를 위한 주성분 분석의 적용 가능성에 대한 연구)

  • Kim, Kimin;Park, Suwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.159-167
    • /
    • 2019
  • In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Pinpointing of Leakage Location Using Pipe-fluid Coupled Vibration (파이프-유체의 연성진동을 이용한 누수위치 식별연구)

  • 이영섭;윤동진
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.95-104
    • /
    • 2004
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, accelermeters aroused to detect leak locations which could provide an easier and more efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long and a 70m-long experimental pipeline systems are installed and the results with the systems show that the algorithm with the accelerometers offers accurate pinpointing for leaks location detection. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.