• Title/Summary/Keyword: Data Leakage Detection

Search Result 141, Processing Time 0.023 seconds

A System for Improving Data Leakage Detection based on Association Relationship between Data Leakage Patterns

  • Seo, Min-Ji;Kim, Myung-Ho
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.520-537
    • /
    • 2019
  • This paper proposes a system that can detect the data leakage pattern using a convolutional neural network based on defining the behaviors of leaking data. In this case, the leakage detection scenario of data leakage is composed of the patterns of occurrence of security logs by administration and related patterns between the security logs that are analyzed by association relationship analysis. This proposed system then detects whether the data is leaked through the convolutional neural network using an insider malicious behavior graph. Since each graph is drawn according to the leakage detection scenario of a data leakage, the system can identify the criminal insider along with the source of malicious behavior according to the results of the convolutional neural network. The results of the performance experiment using a virtual scenario show that even if a new malicious pattern that has not been previously defined is inputted into the data leakage detection system, it is possible to determine whether the data has been leaked. In addition, as compared with other data leakage detection systems, it can be seen that the proposed system is able to detect data leakage more flexibly.

Dynamic data validation and reconciliation for improving the detection of sodium leakage in a sodium-cooled fast reactor

  • Sangjun Park;Jongin Yang;Jewhan Lee;Gyunyoung Heo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1528-1539
    • /
    • 2023
  • Since the leakage of sodium in an SFR (sodium-cooled fast reactor) causes an explosion upon reaction with air and water, sodium leakages represent an important safety issue. In this study, a novel technique for improving the reliability of sodium leakage detection applying DDVR (dynamic data validation and reconciliation) is proposed and verified to resolve this technical issue. DDVR is an approach that aims to improve the accuracy of a target system in a dynamic state by minimizing random errors, such as from the uncertainty of instruments and the surrounding environment, and by eliminating gross errors, such as instrument failure, miscalibration, or aging, using the spatial redundancy of measurements in a physical model and the reliability information of the instruments. DDVR also makes it possible to estimate the state of unmeasured points. To validate this approach for supporting sodium leakage detection, this study applies experimental data from a sodium leakage detection experiment performed by the Korea Atomic Energy Research Institute. The validation results show that the reliability of sodium leakage detection is improved by cooperation between DDVR and hardware measurements. Based on these findings, technology integrating software and hardware approaches is suggested to improve the reliability of sodium leakage detection by presenting the expected true state of the system.

Analysis of Flow and Economic Benefit Through Water Leakage Detection and Repair (누수탐사에 의한 유량분석 및 보수의 경제적 효과)

  • Lee, Seung-Chul;Lee, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2005
  • Field measurement data on water leakage are not readily available and it causes inaccurate assessment of water demand and poor supply planning. In this study, the procedure for leakage detection and unaccounted water calculation is proposed and applied to a city. The city has suffered from the significant amount of leak water and the financial loss as a result. Measurements were made for pressure and flow at 18 locations before and after the repair. Repair of the leakage increased pressure up to $2.0kgf/cm^2$ and saved 17.1% of water supply from distribution reservoirs. Monetary value of annual water savings for the entire city amounts to 1 billion won. It is believed that leakage detection and data analysis conducted in this study will contribute to the change of current practice and to the establishment of better water supply management system.

New Approach for Detecting Leakage of Internal Information; Using Emotional Recognition Technology

  • Lee, Ho-Jae;Park, Min-Woo;Eom, Jung-Ho;Chung, Tai-Myoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.11
    • /
    • pp.4662-4679
    • /
    • 2015
  • Currently, the leakage of internal information has emerged as one of the most significant security concerns in enterprise computing environments. Especially, damage due to internal information leakage by insiders is more serious than that by outsiders because insiders have considerable knowledge of the system's identification and password (ID&P/W), the security system, and the main location of sensitive data. Therefore, many security companies are developing internal data leakage prevention techniques such as data leakage protection (DLP), digital right management (DRM), and system access control, etc. However, these techniques cannot effectively block the leakage of internal information by insiders who have a legitimate access authorization. The security system does not easily detect cases which a legitimate insider changes, deletes, and leaks data stored on the server. Therefore, we focused on the insider as the detection target to address this security weakness. In other words, we switched the detection target from objects (internal information) to subjects (insiders). We concentrated on biometrics signals change when an insider conducts abnormal behavior. When insiders attempt to leak internal information, they appear to display abnormal emotional conditions due to tension, agitation, and anxiety, etc. These conditions can be detected by the changes of biometrics signals such as pulse, temperature, and skin conductivity, etc. We carried out experiments in two ways in order to verify the effectiveness of the emotional recognition technology based on biometrics signals. We analyzed the possibility of internal information leakage detection using an emotional recognition technology based on biometrics signals through experiments.

Evaluation of leakage detection performance according to leakage scenarios of water distribution systems based on deep neural networks (DNN기반 상수도시스템 누수시나리오에 따른 누수탐지성능 평가)

  • Kim, Ryul;Choi, Young Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.5
    • /
    • pp.347-356
    • /
    • 2023
  • In Water Distribution Systems (WDSs), can abnormal hydraulic and water quality conditions such as red-water phenomenon and leakage occur. To restore them, data is generated through various meters data to predict and detect. However, in the case of leakage if difficult to detect unless direct exploration is performed. Among them, unreported leakage, are not seen visually and account for the most considerable volumes of leakage, which leads to economic loss. Bur direct exploration is limited through on site conditions such as securing professional manpower. In this paper, leakage volumes and location were randomly generated for the WDS, which was assumed to be calibrated, and it was detected through a deep learning model. For abnormal data generation, the leakage was simulated using the emitter coefficient, and leakage detection was successfully performed through the generated abnormal data and normal data.

Feasibility Study on the Landfill Monitoring and Leakage Detection System

  • Park, Jun-Boum;Kwon, Ki-Bum;Oh, Myoung-Hak;Mishra, Anil Kumar
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.558-569
    • /
    • 2007
  • It is important to obtain real-time data from long-term monitoring of landfills and develop leachate leakage detection system for the integrated management of landfills. A novel real time monitoring system and early leakage detection system was suggested in this study. The suggested monitoring system is composed of two parts; (1) a set of moisture sensors which monitor the areas surrounding the landfill, and (2) a set of moisture and temperature sensors which monitor the landfill inside. For the assessment for landfills stabilization, real-time monitoring system was evaluated in dry and wet cell of pilot-site. In addition, the grid-net electrical conductivity measurement system was also suggested as early leakage detection system. In this study, the field applicability of suggested systems was evaluated through pilot-scale field tests. The results of pilot-scale field model tests indicate that the grid-net electrical conductivity measurement method can be applicable to the detection of landfill leachate at the initial stage of intrusion, and thus has a potential for monitoring leachate leakage at waste landfills.

  • PDF

A Study on Fault Diagnosis of Boiler Tube Leakage based on Neural Network using Data Mining Technique in the Thermal Power Plant (데이터마이닝 기법을 이용한 신경망 기반의 화력발전소 보일러 튜브 누설 고장 진단에 관한 연구)

  • Kim, Kyu-Han;Lee, Heung-Seok;Jeong, Hee-Myung;Kim, Hyung-Su;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1445-1453
    • /
    • 2017
  • In this paper, we propose a fault detection model based on multi-layer neural network using data mining technique for faults due to boiler tube leakage in a thermal power plant. Major measurement data related to faults are analyzed using statistical methods. Based on the analysis results, the number of input data of the proposed fault detection model is simplified. Then, each input data is clustering with normal data and fault data by applying K-Means algorithm, which is one of the data mining techniques. fault data were trained by the neural network and tested fault detection for boiler tube leakage fault.

Transient Analysis and Experiment Considering Unsteady Friction and Leakage in a Pipeline System (단일관망에서 누수효과를 고려한 천이류 분석 및 실험)

  • Lee, Mi-hyun;Song, Yong-sok;Kim, Sang-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.207-214
    • /
    • 2006
  • The current paper focuses the analysis of leakage detection in water pipeline systems by means of the transient method. In order to obtain essential data for evaluation the existing methodology, an extensive experimental process has been carried out in a single pipeline system, Several experimental tests were performed with and without a leakage in the system. Using the unsteady friction and improved unsteady friction factors gives reasonable match between the computed and measured results on the condition of the flow situations presented in the paper. The transient method attempts to estimate the leakage in water pipelines using observed pressure data collected during transient events on the system.

A Feasibility Study on the Detection of Water Leakage using a Ground-Penetrating Radar (지하 탐사 레이더를 이용한 누수탐지 가능성 연구)

  • 오헌철;조유선;현승엽;김세윤
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.6
    • /
    • pp.616-624
    • /
    • 2003
  • The exhaustion of our water resource due to the leakage of waterworks renders it urgent to detect water leakage effectively. In the paper, the detection of water leakage makes use of a pound-penetrating radar(GPR). The region of water leakage is implemented by an acryl box filled with methanol, and then the scale-down experiments are performed by using the GPR system developed in our laboratory. The validity of GPR experiments is assured by showing that the measured data agree well with those finite-difference time-domain(FDTD) simulated results in the same situation. The feasibility of GPR system for the detection of water leakage is investigated by displaying B-scan images according to the distribution of water leakage.

Application of Transient and Frequency Analysis for Detecting Leakage of a Simple Pipeline (누수탐지를 위한 천이류와 주착수분석 적용 연구)

  • Kim, Hyung-Geun;Kim, Hyun-Soo;Lee, Mi-Hyun;Kim, Sang-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1065-1071
    • /
    • 2005
  • Many techniques of leak detection in pipeline systems have developed based on the propagation wave speeds and wave attenuation. In this paper, the transient analysis methodology is used for calculating the wave speed in the plastic pipe and a frequency analysis methodology is developed for leakage detection in water pipe networks. Data acquisition system for pressurized pipeline system were designed md fabricated to obtain high frequency pressure data. The methodology properly handles the unavoidable uncertainties in measurement and modeling error. Based on information from head pressure test data, it provides leak prediction capability from the transient events with leakage.