• Title/Summary/Keyword: Data Generator

Search Result 1,200, Processing Time 0.034 seconds

The thermodynamic efficiency characteristics of combined cogeneration system of 120MW (120MW급 열병합 복합발전시스템의 열역학적 효율 특성)

  • Choi, Myoungjin;Kim, Hongjoo;Kim, Byeongheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.29-36
    • /
    • 2017
  • In this study, acombined cogeneration power plant produced two types of thermal energy and electric or mechanical power in a single process. The performance of each component of the gas turbine-combined cogeneration system was expressed as a function of the fuel consumption of the entire system, and the heat and electricity performance of each component. The entire system consisted of two gas turbines in the upper system, and two heat recovery steam generators (HRSG), a steam turbine, and two district heat exchangers in the lower system. In the gas turbine combined cogeneration system, the performance test after 10,000 hours of operation time, which is subject to an ASME PTC 46 performance test, was carried out by the installation of various experimental facilities. The performance of the overall output and power plant efficiency was also analyzed. Based on the performance test data, the test results were compared to confirm the change in performance. This study performed thermodynamic system analysis of gas turbines, heat recovery steam generators, and steam turbines to obtain the theoretical results. A comparison was made between the theoretical and actual values of the total heat generation value of the entire system and the heat released to the atmosphere, as well as the theoretical and actual efficiencies of the electrical output and thermal output. The test results for the performance characteristics of the gas turbine combined cogeneration power plant were compared with the thermodynamic efficiency characteristics and an error of 0.3% was found.

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF

Effect on Quality Change of Cherry Tomato by $CO_2$ Concentration of Flushed Gas and Storage Period (충전가스의 $CO_2$ 함량 및 노출기간의 변화가 방울토마토의 품질변화에 미치는 영향)

  • Lee, Seung Yuan;Lee, Seung Jae;Choi, Dong Soo;Hur, Sun Jin
    • Culinary science and hospitality research
    • /
    • v.20 no.6
    • /
    • pp.200-210
    • /
    • 2014
  • The purpose of this study was to investigate the quality changes and contamination of microorganisms such as Escherichia coli, mold and yeast in cherry tomatoes during storage at different temperatures, gas composition and periods(7 and 14 days). This study determined pH, color change and the growth pattern of microorganisms in cherry tomato during storage at $5^{\circ}C$, $10^{\circ}C$ and $15^{\circ}C$. According to the results, pH level was a little raised with storage period. On average, $L^*$, $a^*$ and $b^*$ value of cherry tomato were irregular value of increase and decrease of all gas packaging with storage period. In regard of the types of microorganism, aerobic count plate, coliform count, mold and yeast were detected when cherry tomatoes were stored at $5^{\circ}C$, $10^{\circ}C$ and $15^{\circ}C$ during storage for 14 days. Equally, all microorganisms of cherry tomato were irregular with storage period and complex gas packaging. However, this study determined that packaging with a higher $CO_2$ concentration than $O_2$ concentration can reduce growth of microorganism. These studies can be used as primary data for determining the optimal complex gas to storage enlargement.

Generalization of Galois Linear Feedback Register (갈로이 선형 궤환 레지스터의 일반화)

  • Park Chang-Soo;Cho Gyeong-Yeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.1 s.307
    • /
    • pp.1-8
    • /
    • 2006
  • This thesis proposes Arithmetic Shift Register(ASR) which can be used as pseudo random number generator. Arithmetic Shift. Register is defined as progression that multiplies random number D , not 0 or 1 at initial value which is not 0, and it is represented as ASR-D in this thesis. Irreducible polynomial that t which makes $'D^k=1'$ satisfies uniquely as $'t=2^n-1'$ over. $GF(2^n)$ is the characteristic polynomial of ASR-D , and the cycle of Arithmetic Shift Register has maximum cycle as $'2^n-1'$. Galois Linear Feedback Shift Register corresponds to ASR-2-1. Therefore, Arithmetic Shift Register proposed in this thesis generalizes Galois Linear Feedback Shift Register. Linear complexity of ASR-D over$GF(2^n)$ is $'n{\leq}LC{\leq}\frac{n^2+n}{2}'$ and in comparison with existing Linear Feedback Shift Register stability is high. The Software embodiment of arithmetic shift register proposed in this thesis is efficient than that of existing Linear Shift Register and hardware complexity is equal. Arithmetic shift register proposed in this thesis can be used widely in various fields such as cipher, error correcting codes, Monte Carlo integral, and data communication etc along with existing linear shift register.

A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose (방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.544-551
    • /
    • 2014
  • This paper suggests an algorithm to measure low-level radiation by radiation measuring devices, and the other algorithm to improve reaction speed of the device to better respond to dramatic changes in radiation amount. The former algorithm to improve the accuracy of measuring low-level radiation takes advantage of a dual window radiation measurement method which is based on accumulated average of pulses gathered by a radiation measuring sensor. The latter algorithm is to enhance reaction speed of a measuring device to more sensitively react to dramatic changes in radiation amount by adopting a dual window radiation measurement method which analyzes data patterns newly put into for six seconds. To verify the suggested algorithms, a hardware-which consists of sensor and high-voltage generator, controller, charger and power supply circuit, wireless communication part, and display part-was used. Tests conducted on the dual window radiation measurement method as used in the suggested algorithm have proved that accuracy improves to measure low-level radiation of 5uSv/h, and linearity also gets better. Other tests were conducted to see whether the suggested algorithm enhances the reaction speed of a radiation measuring device so that the device responds better to dramatically changing radiation amount. The experimental results have shown meaningful changes in numbers after six seconds. Therefore, the conclusions are made that the algorithm enhances the reaction speed of the device.

Flood Inflow Estimation at Large Multipurpose Dam using Distributed Model with Measured Flow Boundary Condition at Direct Upstream Channels (직상류 계측유량경계조건과 분포형모델을 이용한 대규모 다목적댐 홍수유입량 산정)

  • Hong, Sug-Hyeon;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1039-1049
    • /
    • 2015
  • The inflow estimation at large multipurpose dam reservoir is carried out by considering the water balance among the discharge, the storage change during unit time interval obtained from the observed water level near dam structure and area-volume curve. This method can be ideal for level pool reservoir but include potential errors when the inflow is influenced by the water level slope due to backwater effects from upstream flood inflows and strong wind induced by typhoon. In addition, the other uncertainties arisen from the storage reduction due to sedimentation after the dam construction and water level noise due to mechanical vibration transmitted from the electric power generator. These uncertainties impedes the accurate hydraulic inflow measurement requiring exquisite hydrometric data arrangement for reservoir waterbody. In this study, the distributed hydrologic model using UBC-3P boundary setting was applied and its feasibility was evaluated. Finally, the modeling performance has been verified since the calculated determination coefficient has been in between 0.96 to 0.99 after comparing with observed peak inflow and total inflow at Namgang dam reservoir.

Photo- and Sonic Degradation of Endosulfans(α, β, and sulfate) in Aqueous Solution (엔도설판류의 광 및 초음파분해)

  • Kwon, Sung Hyun;Kim, Jong Hyang;Cho, Daechul
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.460-465
    • /
    • 2007
  • Endosulfan-${\alpha}$ endosulfan-${\beta}$ and endosulfan-sulfate, which are classified as pesticides, were degraded by use of UV energy and ultrasonic irradiation. The degradation residuals were analysed by gas chromatography with an electron capture detector and TOC (total oragnic carbon) analysis. The reactions were conducted in a quartz annular reactor equipped with a low pressure mercury multilamp (8Wx2) and a sonic generator. All the aqueous solutions were concentrated as 10 mg/L initially. Endosulfans were degraded each to result in 48.2% (${\alpha}$), 50.0% (${\beta}$) and 76.5% (sulfate) of removal efficiency by UV energy, and 66.9% (${\alpha}$), 55.8% (${\beta}$) and 72.7% (sulfate) by ultrasonic irradiation, respectively. In contrast to the results of the single-component solutions, degradation of the endosulfan-sulfate was greatly suppressed to result in the lowest degradation rate and removal efficiency in the three-component solutions. This finding suggests that there should be a reversible reaction with a substantially low equilibrium constant between endosulfan-${\alpha}$ or -${\beta}$ and -sulfate in the coexistence of the three endosulfans. TOC data showed the endosulfans were decomposed by 20%~40% toward complete mineralization, producing a quantity of intermediates induced by the radical reactions. We found that all the decay reactions considered in this study nicely fell into pseudo first-order rate.

Damage of radioprotection and antitumor effects of water-soluble propolis

  • Terai, Kaoru;Ryu, Myung-Sun;Itokawa, Yuka;Maenaka, Toshihiro;Nakamura, Takashi;Hasegawa, Takeo;Choi, In-Suk;Ishida, Torao;Gu, Yeun-Hwa
    • Advances in Traditional Medicine
    • /
    • v.6 no.1
    • /
    • pp.12-20
    • /
    • 2006
  • Some natural products are able to inhibit radiation effects and exert an antitumor effect with fewer adverse reactions; however, their antitumor effects are less than those of widely-used synthetic drugs. Propolis is a natural material that has been attracting attention, and we extracted this material with water and investigated the effect of continuous propolis administration on radioactivity-induced reduction of hemocytes, in addition to the antioxidant and antitumor effects of propolis. Following a 1-week adjustment period, water-soluble propolis was administered intraperitoneally to male ICR mice at a dose of 100 mg/kg every other day for 2 weeks. Following administration, 2 Gy whole-body irradiation was performed and the counts of leukocytes, lymphocytes, and granulocytes and monocytes in the peripheral blood were determined 1, 3, 7, 15 and 30 days after irradiation. These cells were considered since they are closely associated with immunity to radioactivity. In a second experiment, water-soluble propolis was similarly administered to the mice for 2 weeks after a 1-week adjustment period, and 2 Gy whole-body irradiation was performed. The antioxidant effects in hemocytes were then investigated using 2,2'-azobis (2-amidinopropane) dihydrochloride (AAPH), a radical generator. In a third experiment, $1\;{\times}\;10^6$ Sarcoma-180 cells were inoculated into the right thigh of mice, which were divided into four groups: control, water-soluble propolis-treated, 6 Gy irradiated and water-soluble propolis-treated + 6 Gy irradiated groups, and changes in tumor size were measured for 20 days. Statistical analysis was conducted using ANOVA for multiple groups. In the three experiments, administration of water-soluble propolis inhibited the reduction of hemocytes caused by whole-body irradiation, showed antioxidant effects against radioactivity, and inhibited tumor growth, respectively. In conclusion, our data suggest that the antioxidant effect of watersoluble propolis inhibits hemocyte reduction caused by whole-body irradiation and enhances immunological inhibition of tumor growth.

Determination of the Hypocentral Parameters Outside The Seismic Array Using a Single Station of Three-Component (지진관측망 밖의 진원결정과 3-성분 단일 지진관측에 관해서)

  • 김소구;이승규
    • The Journal of Engineering Geology
    • /
    • v.5 no.1
    • /
    • pp.59-74
    • /
    • 1995
  • It is well known that the hypocentral parameters inside the seismic array are well determined using HYPO71PC Programs. These programs, however, do not woik well for the non-evenly distribution of the seismic stations and/or the seismic events outside the seismic array. Furthermore it is very difficult to determine the exact locations of small events in North Korea since there is no seismological data exchange between South and North Koreas. We used the polarization method of the single-station with 3-component in addition to HYPO71PC(IASPEI's Program) in order to determine the source parameters of shallow-focus earthquakes outside the seismic array. First of all, we tested the interior events of the Uisung earthquake, April 14, 1991 and the Mt. Keyryong earthquakes, Feorirary 12, 1994, and two exterior events of W. Pyoungyang earthquake, Noventer 12, 1992, and Yellow Sea earthquake, July 26, 1994 to investigate the convergence and divergence to calculate the source parameters. We have found that the source determination outside the seismic array never converges to the exact location whereas the any events inside the array quickly converge to the exact location. The seismic events outside the array such as two events Vladivostok and East Sea, and the Yellow Sea event are more accurately determined using the polarization method. Estimating the source azimuth is carried out by estimating the polarization direction of the interesting phases and the range estimate is made frum the relative timing of different phases. The polarization method is verified by fmding that the estimates of azimuths and incidence angles by the polarization method are identical with those of the synthetic seismograms of the modellings using the generator program.

  • PDF

Water Quality Modelling of Flood Control Dam by HSPF and EFDC (HSPF-EFDC 모델을 연계한 홍수조절댐 수질 변화 예측)

  • Lee, Young-Gi;Hwang, Sang-Chul;Hwang, Hyun-Dong;Na, Jin-Young;Yu, Na-Young;Lee, Han-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.3
    • /
    • pp.251-266
    • /
    • 2018
  • This study predicted the effect of operation pattern of flood control dam on water quality. Flood control dam temporarily impound floodwaters and then release them under control to the river below the dam preventing the river ecosystem from the extreme flood. The Hydrological Simulation Program Fortran (HSPF) and the Environmental Fluid Dynamics Code (EFDC) were adapted to predict the water quality before and after the dam construction in the proposed reservoir. The non-point pollutant delivery load from the river basin was estimated using the HSPF, and the EFDC was used to predict the water quality using the provided watershed boundary conditions from the HSPF. As a result of water quality simulation, it is predicted that the water quality will be improved due to the decrease of pollution source due to submergence after dam construction and temporary storage during rainfall. There would be no major water quality issues such as the eutrophication in the reservoir since the dam would impound the floodwater for a short time (2~3 days). In the environmental impact assessment stage of a planned dam, there may be some limitations to the exact simulation because the model can not be sufficiently calibrated. However, if the reliability of the model is improved through the acquisition of actual data in the future, it will be possible to examine the influence of the water environment according to various operating conditions in the environmental impact assessment of the new flood control dam.