• Title/Summary/Keyword: Data Flow Control

Search Result 1,287, Processing Time 0.027 seconds

Reduced Order Modeling of Backward-Facing-Step Flow Field (후향계단 유동장 축약모델링 기법)

  • Lee, Jin-Ik;Lee, Eun-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.10
    • /
    • pp.833-839
    • /
    • 2012
  • In this paper, we analyze the reconstruction error in the modeling of flow field on BFS(Backward Facing Step). In order for the mathematical modelling of a density on the field, the spatial and temporal modes are extracted by POD(Proper Orthogonal Decomposition) method. After formulating the modeling error, we summarize the relationship between the energy strength and the reconstruction errors. Moreover the allowable modeling error limits in the flow control point of view are confined by analysing in the frequency domain as well as time domain of the reconstructed data.

A study on Acoustic Similarity of Cavitating Valve Noise (밸브소음 스케일링에 관한 연구)

  • 이재환;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.471-477
    • /
    • 1998
  • A constant flow-rate control valve provides effective distributions and controls of running water in a pipe system. The noise characteristics were measured to reveal the noise sources depending on pressure differences across a valve. Valve noise is mostly dominated by bubble dynamics under cavitating conditions. In this study, the sound powers from a flow control valve of constant flow rates are effectively normalized. Flow-excited dynamic systems for which there is no strong coupling between the flow and the system response can be described using a linear source-filter model. On this assumption, the normalized sound powers can be decomposed of noise source function and a response function. The source spectra in, terms of cavitation frequency show cavitation events occurring at narrow banded frequencies greater than 10 kHz. There also possibly exist two kinds of cavitating modes based on our experimental data.

  • PDF

Computational Study on the Fluidic Thrust Vectoring of a Propellant Jet (추진제트의 Fluidic Thrust Vectoring에 관한 수치해석 연구)

  • 김재형;임채민;김희동;조재필
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.23-26
    • /
    • 2003
  • Recently, the thrust vector control using a secondary flow injection which is accomplished by injecting a secondary flow into the supersonic exhaust flow through hole in the wall of the propulsion nozzle has been attention in the applications of the rocket propulsion system. In the present study, 3-dimensional compressible, Navier-Stokes equation to understand the SITVC(Secondary Injection Thrust Vector Control) flow field. The computational results are validated with previous experimental data available. The computational results are visualized detailed structure of shock wave induced by secondary flow and deflected supersonic jets.

  • PDF

A Study on the Localization of 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump (보일러 급수펌프용 1500lb 고차압 제어밸브 국산화 개발에 관한 연구)

  • Lee, Kwon-Il;Jang, Hoon;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.8
    • /
    • pp.19-24
    • /
    • 2022
  • We developed a prototype from the design of a trim, which is the most important in the localization development of a 1500 Ib high-differential pressure-control valve used for boiler feedwater, and measured the flow coefficient, the most basic design data for valves. The following conclusions were drawn. The comparison of the design values of the flow coefficients for the existing X-trim and the multicore trim designed for localization development showed that they were almost identical, and the X-trim value was slightly lower. The comparison of the X-trim and multicore trim based on the valve flow coefficient test showed that they were generally similar, indicating no problem with the design. In the future, we plan to compare and analyze the flow paths for the X-trim and multicore trim via flow analysis.

Evaluation of the Inherent Flow Coefficient of the Control Valve in the Liquid Propellant Rocket Engine (액체로켓 엔진 성능 보정용 제어밸브의 고유유량특성 계산)

  • Park, Soon-Young;Cho, Won-Kook;Seol, Woo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.73-78
    • /
    • 2011
  • When a liquid rocket engine - specifically for the gas-generator cycle engine has throttle valves to control the thrust level and mixture ratio of the engine, it is possible to adjust the inherent flow characteristics of the control valves in order to secure a linearized correlation between the control-process-parameters like the thrust or mixture ratio of an engine and the throttle angle of valve. These linearities can reduce the complexity of the control process and make the process more explicit by ensuring the intuitive control. In this point, we proposed an algorithm within the frame of the in-house-developed program to obtain the control valves' inherent flow characteristics which satisfy the linearity, and calculated the sensitivities of control valves with respect to the throttle angle. Also, we compared the obtained inherent flow characteristics with the existed data and concluded the results are satisfactory.

Host Interface Design for TCP/IP Hardware Accelerator (TCP/IP Hardware Accelerator를 위한 Host Interface의 설계)

  • Jung, Yeo-Jin;Lim, Hye-Sook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.2B
    • /
    • pp.1-10
    • /
    • 2005
  • TCP/IP protocols have been implemented in software program running on CPU in end systems. As the increased demand of fast protocol processing, it is required to implement the protocols in hardware, and Host Interface is responsible for communication between external CPU and the hardware blocks of TCP/IP implementation. The Host Interface follows AMBA AHB specification for the communication with external world. For control flow, the Host Interface behaves as a slave of AMBA AHB. Using internal Command/status Registers, the Host Interface receives commands from CPU and transfers hardware status and header information to CPU. On the other hand, the Host Interface behaves as a master for data flow. Data flow has two directions, Receive Flow and Transmit Flow. In Receive Flow, using internal RxFIFO, the Host Interface reads data from UDP FIFO or TCP buffer and transfers data to external RAM for CPU to read. For Transmit Flow, the Host Interface reads data from external RAM and transfers data to UDP buffer or TCP buffer through internal TxFIFO. TCP/IP hardware blocks generate packets using the data and transmit. Buffer Descriptor is one of the Command/Status Registers, and the information stored in Buffer Descriptor is used for external RAM access. Several testcases are designed to verify TCP/IP functions. The Host Interface is synthesized using the 0.18 micron technology, and it results in 173 K gates including the Command/status Registers and internal FIFOs.

A Study on the Two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force (전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구)

  • Bae Hyung-Sub;Yang Taek-Joo;Lee Yuk-Hyung;Joo Dong-Woo;Park Myeong-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.29-37
    • /
    • 2005
  • In this study, the control of the free surface deformation of a magnetic fluid for the change in electromagnetic force is discussed. The free surface of magnetic fluid is formed by the balance of surface force, gravity, pressure difference, magnetic normal pressure and magnetic body force. Magnetic fluid in characteristics of fluid adjusted to the opposite direction of the gravity direction. Thus, the device of a magnetic fluid proposed the complete zero-leakage sealing, oscillator for surface control, boundary layer control, MHD, flow control, flow using magnetic levitation system and surface actuator. This study show the deformation of surface rise due to the intensity of the magnetic field and possibility of two-dimensional control of magnetic fluid through the feedback data of hall sensor.

Mobile Oriented Future Internet (MOFI): OpenFlow-based Implementation and Testbed Experimentation over KOREN (모바일 중심 미래 인터넷: OpenFlow 기반 구현 및 KOREN 테스트베드 실험)

  • Kim, Ji-In;Jung, Heeyoung;Koh, Seok-Joo
    • Journal of KIISE:Information Networking
    • /
    • v.41 no.4
    • /
    • pp.167-176
    • /
    • 2014
  • In this paper, we discuss the implementation and experimentations of a new future Internet architecture for mobile-oriented environments, named Mobile Oriented Future Internet (MOFI). The MOFI architecture is featured by the host identifier and local locator for identifier-locator separation, Query-First Data Delivery (QFDD), and Distributed Mapping System (DMS) for identifier-locator mapping control. In the existing study on MOFI, we examined the intra-domain mobility control, the implementation of MOFI over Linux platform, and the performance analysis over the small-scale testbed. In this paper, we describe how to implement the MOFI architecture for inter-domain mobility control by using the OpenFlow and Click Modular Router platform. From the experimentations over the KOREN testbed, we can see that the MOFI scheme can give better performance than the existing Proxy Mobile IP scheme.

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

Application of Intelligent Technique for the Efficient Operation of the Flexible Manufacturing System (유연생산시스템의 효율적 운용을 위한 지능적 기법의 적용에 관한 연구)

    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.2
    • /
    • pp.1-15
    • /
    • 1999
  • This research involves the development and evaluation of a work flow control model for a type of flexible manufacturing system(FMS) called a flexible flow line(FFL). The control model can be considered as a kind of hybrid intelligent model in that it utilizes both computer simulation and neural network technique. Training data sets were obtained using computer simulation of typical FFL states. And these data sets were used to train the neural network model. The model can easily incorporate particular aspects of a specific FFL such as limited buffer capacity and dispatching rules used. It also dynamically adapts to system uncertainty caused by such factors as machine breakdowns. Performance of the control model is shown to be superior to the random releasing method and the Minimal Part Set(MPS) heuristic in terms of machine utilization and work-in-process inventory level.

  • PDF