• Title/Summary/Keyword: Data Diode

Search Result 362, Processing Time 0.027 seconds

Evaluation of Residual Pesticides in Fresh Ginseng Collected in Seoul

  • Kim, Tae-Rang;Park, Ki-Hwan;Jang, Mi-Ra;Choi, Young-Hee;Kim, Eun-Hee;Choi, Chae-Man;Park, Sung-Kyu;Yu, In-Sil;Hwang, In-Sook;Han, Ki-Young;Kim, Moo-Sang;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • This study was performed to analyze 48 kinds of pesticide residues using gas chromatography (GC)/nitrogen phosphorous detector, GC/micro electron capture detector, GC/mass selective detector, and high performance liquid chromatograph/diode array detector in 186 fresh ginseng samples collected in the Seoul area from 2010 to 2011. Fresh ginseng dietary intakes were estimated using the data from the 2009 Korea National Health and Nutrition examination survey. Residual pesticides were detected in 79 samples (42.5%) with eight different fungicides. Only 20 samples (10.8%) exceeded the maximum residue limits (MRLs) for pesticides registered by the Korea Food & Drug Administration. Among them, tolclofos-methyl residues (10.2%) exceeded the MRL for fresh ginseng in 18 ginseng seedlings and one of the two-year old fresh ginseng plants, and the residual level in just one ginseng seedling violated the MRL for pyrimethanil. The results showed that residual pesticides levels in marketable fresh ginseng around Seoul were relatively safe. The percent acceptable daily intake (%ADI) was calculated using pesticide residues in fresh ginseng and dietary intakes of fresh ginseng. The risk caused by pesticide residues in fresh ginseng was very low.

Dissipation characteristics of mandipropamid and thiamethoxam for establishment of pre-harvest residue limits in lettuce (상추의 생산단계 잔류허용기준 설정을 위한 농약 Mandipropamid 및 Thiamethoxam의 잔류소실특성 연구)

  • Yang, Seung-Hyun;Lee, Jae-In;Choi, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.63 no.3
    • /
    • pp.267-274
    • /
    • 2020
  • The dissipation characteristics and kinetics of fungicide mandipropamid and insecticide thiamethoxam in lettuce under greenhouse conditions were investigated at three different lettuce-growing fields for estimating the pre-harvest residue limits (PHRLs). The analytical methods were fully validated for the quantitation of pesticide residues using High-Performance Liquid Chromatography-Photo Diode Array detector or Ultraviolet-Visible Detector and applied to real samples. The lettuces suitable for shipment were harvested during 10 days including pre-harvest interval after treatment at the recommended dose by safe-use guidelines. The initial mean residues in different fields were 6.68-17.87 and 4.96-8.31 mg/kg for mandipropamid and thiamethoxam, respectively, which decreased to 16-54 and 14-44% in 10 days. The clothianidin, a metabolite of thiamethoxam, was detected in <0.02 to 0.37 mg/kg. The dissipation of both pesticides followed first-order kinetics over a period of 10 days after application. Based on the residue data, the mean dissipation rate constant (λ) and biological half-lives (T1/2) were estimated to be -0.1060 and 6.5 days of mandipropamid and -0.1236 and 5.6 days of thiamethoxam. The PHRLs for lettuce on the 10th and 5th day before harvesting were calculated to be 63.24 and 43.56 mg/kg for mandipropamid, and 44.66 and 25.88 mg/kg for thiamethoxam, with -0.0746 and -0.1091 of the upper 95% confidence intervals of dissipation rate constant, respectively. This work would be useful as guidance for adjusting the shipment date and contribute to stabilizing the income of farmers in Korea.

Driving Current Control for Time-Stable RGB LED Backlighting Using Time-Varying Transform Matrix (시변 변환 행렬을 이용한 시간에 안정된 RGB LED Backlighting 구동 전류 제어)

  • Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.4
    • /
    • pp.42-49
    • /
    • 2009
  • This paper proposes a driving current control method for a back light unit (BLU), consisting of red, green, and blue (RGB) light-emitting diodes (LEDs), whereby an RGB optical sensor is used to check the output color stimulus variation to enable a time-stable color stimulus for light emission by the RGB LED BLU. First, to obtain the present color stimulus information of the RGB LED BLU, an RGB to XYZ transform matrix is derived to enable CIEXYZ values to be calculated for the RGB LED BLU from the output values of an RGB optical sensor. The elements of the RGB to XYZ transform matrix are polynomial coefficients resulting from a polynomial regression. Next, to obtain the proper duty control values for the current supplied to the RGB LEDs, an XYZ to Duty transform matrix is derived to calculate the duty control values for the RGB LEDs from the target CIEXYZ values. The data used to derive the XYZ to Duty transform matrix are the CIEXYZ values for the RGB LED BLU estimated from the output values of the RGB optical sensor and corresponding duty control values applied to the RGB LEDs for the present, first preceding, and second preceding sequential check points. With every fixed-interval check of the color stimulus of the RGB LED BLU, the XYZ to Duty transform matrix changes adaptively according to the present lighting condition of the RGB LED BLU, thereby allowing the RGB LED BLU to emit the target color stimulus in a time-stable format regardless of changes in the lighting condition of the RGB LEDs.

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Notes on Methods for Realization and Analysis for Implementation of Traditional Aesthetic Value (전통 조형정신의 구현체계의 분석 방법과 실현 방안에 관한 고찰)

  • 민경우
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.335-342
    • /
    • 2004
  • Recently there have been various research activities regarding Korean traditional aesthetics. However, those researches were mainly conducted individually, partially, and periodically, which resulted in unsystematic and incomprehensive works. Therefore, it is required to orginze all the precedent research works with more systematic and objective framework. Generally speaking, all the human activities including aesthetic activity have ends, procedure and means. In other words, human being needs three key elements for realizing any thought and those three elements include contents, formal, and practical element. Element of contents is ultimate goal to accomplish as value, concept, and meaning of thought with their aims. Formal element includes methods, principles, norms, procedure, formality and style comprising of thought in order to accomplish the goal. Finally, practical element refers to specific means, tool, media, material and techniques to concretize the contents through form. Almost all of thoughts and meaning which human being tries to express consist of language. Major elements in sentence include 'subject (omissible)' , 'objects (aim)', 'predicate (formality)', 'complement (means)' and they are composed systematically and hierarchically with rules in sentence. The study compared human activity model with language structure and analyzed their implication with design (aesthetics), which made it possible to propose analytic frameworks for traditional aesthetics. In addition, the study also systematically organized the way to realize traditional aesthetic value in the present context based on the methods developed in this study.

  • PDF

Comparison of the Characteristics of Seed Germination and the First Stage of Growth in Cynanchum wilfordii (Maxim.) by Different Light Conditions (광조건별 백수오의 종자 발아 특성 및 초기생육 비교)

  • Yoo, Ji Hye;Seong, Eun Soo;Lee, Jae Geun;Kim, Chul Joong;Choi, Jae Hoo;Lee, Gi Hye;Hwang, In Seong;Hwang, Eun Bee;Lim, Jung Dae;Ahn, Young Sup;Park, Chung Berm;Yu, Chang Yeon
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.5
    • /
    • pp.329-333
    • /
    • 2013
  • This study was carried out to compare the characteristics of seed germination and the first stage of growth in Cynanchum wilfordii (Maxim.) by different light conditions such ass fluorescent light, dark and light emitting diode (LED). There was not much difference from the germination rate of C. wilfordii (Maxim.) in different light conditions for 10 days. The highest of germination rate occurred over 91.11 percentage by LED red condition at $26^{\circ}C$. Also mean germination velocity and promptness index were represented the highest results of 2.3 ea/day and 52.67 under red light, respectively. But mean germination time under both LED red and blue light was represented low data that it takes over three days for germinating of seed. Even though handling both LED red and blue lights, the germination uniformity was not constant. These results may help our understanding of variations in germination characteristics for C. wilfordii (Maxim.) seeds treated under different light conditions.

Development of Customizable Fluorescence Detection System using 3D Printer (3D 프린터를 활용한 맞춤형 휴대용 형광측정 장치 개발)

  • Cho, Kyoung-rae;Seo, Jeong-hyeok;Choe, Se-woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.278-280
    • /
    • 2019
  • Flow cytometer is one of the instrument that can measure various optical properties of a single cell or microparticle. These parameters including size, granularity, and fluorescence intensity are determined by the physical and optical interaction of the cells with excitation light source. However, users have some difficulties such as high cost, size of instrument, and limited fluorescence selectivity. In addition, abundant data is also unintentionally acquired even though user wants to have a single optical parameter. For these reasons, the use of flow cytometer is more challenging for researchers to apply their study. Therefore, the proposed study aims to develop a low-cost portable fluorescence acquisition system using a commercially available light-emitting diode and photodiode. It is designed by a 3D printer, and fluorescence selectivities are increased by changing of the light source / optical filter / detection sensor. Various number sets of fluorescently labeled cells were measured, and its feasibility was evaluated through the proposed system. As a result, acquried fluorescence intensities were proportional to the concentration of the cells and showed high linearity.

  • PDF

Fabrication and Evaluation of Mercury(II) Iodide Unit Cell Dosimeter to Confirm the Feasibility of Digital Quality Assurance in Intracavitary Radiotherapy (방사선 근접치료의 디지털 정도관리 가능성 확인을 위한 HgI2 Unit Cell 선량계의 제작 및 평가)

  • Jung, Jae-Hoon;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.257-263
    • /
    • 2022
  • In intracavitary radiotherapy, it is essential to verify the correct location of radiation source among quality control items because an incorrect location will irradiate an unnecessary dose to normal tissues. As a basic study of digital line dosimeters, this study fabricated a unit cell dosimeter based on polycrystalline mercury (II) iodide (HgI2) and compared its performance with a diode. The study result showed that for reproducibility, the relative standard deviation (RSD) was 1.21%, satisfying the RSD evaluation criterion of within 1.5%. Considering linearity, the coefficient of determination R2 showed an excellent result of 0.9997. Regarding the evaluation of distance dependence, it showed a similar trend in general with a difference of 0.035 cm for intensity 50% when compared with the inverse square value. This study suggests the applicability of a digital dosimeter for brachytherapy quality control by evaluating the performance of the HgI2 dosimeter. This study on dosimeter for candidate photoconductor materials can be used as basic data in all areas using radiation.

An Exploratory research on patent trends and technological value of Organic Light-Emitting Diodes display technology (Organic Light-Emitting Diodes 디스플레이 기술의 특허 동향과 기술적 가치에 관한 탐색적 연구)

  • Kim, Mingu;Kim, Yongwoo;Jung, Taehyun;Kim, Youngmin
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.4
    • /
    • pp.135-155
    • /
    • 2022
  • This study analyzes patent trends by deriving sub-technical fields of Organic Light-Emitting Diodes (OLEDs) industry, and analyzing technology value, originality, and diversity for each sub-technical field. To collect patent data, a set of international patent classification(IPC) codes related to OLED technology was defined, and OLED-related patents applied from 2005 to 2017 were collected using a set of IPC codes. Then, a large number of collected patent documents were classified into 12 major technologies using the Latent Dirichlet Allocation(LDA) topic model and trends for each technology were investigated. Patents related to touch sensor, module, image processing, and circuit driving showed an increasing trend, but virtual reality and user interface recently decreased, and thin film transistor, fingerprint recognition, and optical film showed a continuous trend. To compare the technological value, the number of forward citations, originality, and diversity of patents included in each technology group were investigated. From the results, image processing, user interface(UI) and user experience(UX), module, and adhesive technology with high number of forward citations, originality and diversity showed relatively high technological value. The results provide useful information in the process of establishing a company's technology strategy.

Determination of Propionic, Benzoic, and Sorbic Acids in Dried Seasoned Seafood Products in Korea (유통 조미건어포 중 프로피온산, 안식향산, 소브산 함유량 조사)

  • Woojin Jang;Jongyoon Choi;Seongjae Kim;Sang-Do Ha;Jihyun Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.311-318
    • /
    • 2023
  • This study was performed to determine the contents of propionic, benzoic, and sorbic acids in dried seasoned seafood products (n=27) sold in Korea. Propionic acid was determined using a gas chromatogramphy-flame ionization detector. Benzoic and sorbic acid were analyzed by using a high-performance liquid chromatography-diode array detector. Benzoic acid was not detected in the dried seasoned seafood products; however, propionic and sorbic acid were detected in some samples. The concentrations of propionic acid and sorbic acid were up to 125.10 mg/kg and 658.18 mg/kg in dried seasoned seafood products, respectively. Of eight samples labeled with potassium sorbate, sorbic acid was detected in seven of them. The detected sorbic acid levels in these samples met the regulations for sorbic acid usage in Korea. The propionic, benzoic, and sorbic acid contents of dried seasoned seafood products determined in this study can provide basic data for safety management of dried seasoned seafood products in future.