• Title/Summary/Keyword: Data Converter

Search Result 623, Processing Time 0.023 seconds

Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector (비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현)

  • Park, Jae-Hyoun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

Detection of Surges by Frequency Analysis on Lan Equipment (랜설비에 유기되는 이상전압의 주파수분석을 통한 서지의 검출)

  • Huh, Chang-Su;Lee, Se-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.213-215
    • /
    • 2001
  • We investigated the frequency characteristics of surges induced on Lan equipments by using V-F converter. which installed on the second part of protection system. We stored and analyzed the frequency converting data with the amplitude of overvoltage. In addition. The data acquisition system was made so that we could be examine the results wave through WEB. From this results, it is found that this frequency analysis could be helped for design and protection of various undesired surges.

  • PDF

Biomechanical Analysis of Body Balance

  • Jeong, Byung-Yong
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.233-238
    • /
    • 1988
  • Human body sways continuously to maintain balance during upright stance. A computer-aided instrumentation system using a force platform has been developed to investigate the body balance. The Kistler force platform and amplifiers were only used to obtain the precise measurements, and the data acquisition and analysis software operating on an IBM PC with A/D converter was developed. This study presents methods for the display of platform center of pressure data on stability study. This system can be used as a tool in evaluating the man's ability to balance and disorders of the nervous system.

  • PDF

A Computer-aided Analysis and Model of Human Motion (인체동작의 컴퓨터 분석모델)

  • Kim Yeong-Gil
    • Journal of the military operations research society of Korea
    • /
    • v.9 no.2
    • /
    • pp.45-55
    • /
    • 1983
  • Film data photographed by Motor Drive Camera were gathered and recorded in the FM Tape Recorder via computer-aided Location Analyzer and Voltage Generator. The recorded analogue data are converted into digital voltage values corresponding to the location of 14 landmarks by Analog-to-Digital Converter attached to digital computer. Using these converted values, the human motions were reproduced by CalComp Plotter and computer screen. This author concludes that any human motions can be analyzed by computer and we can find some methods of improvements of motions in work places, sports science, or operations of military equipments.

  • PDF

Computer Aided Measurement and Analysis of Body Sway Using Force Platform (힘판을 이용한 중심 동요의 자동측정에 관한 연구)

  • Jeong, Byeong-Yong;Park, Gyeong-Su
    • Journal of the Ergonomics Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.45-52
    • /
    • 1988
  • An instrumentation system for the automatic measurement of body sway has been developed. The system consists of a force platform, amplifiers, and data acquisition and display software, operating on a computer. We used only the force platform and electronic amplifying unit in Kistler Biomechanics System to obtain precise measurements, and developed the data acquisition and analysis software using an IBM PC With 12 bit A/D converter. The system can be used in various specialized disciplines, such as ergonomics, rehabilitation, neuromuscular control, as well as sprots biomechanics.

  • PDF

Implementation of Oscilloscope using Arduino Board (아두이노 보드를 이용한 오실로스코프 구현)

  • Choi, Byeong-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.605-606
    • /
    • 2021
  • In this paper, one channel oscilloscope was implemented using arduino uno board and 1.8 inch TFT LCD. The oscilloscope is designed using the built-in analog to digital converter(ADC) inside arduino uno board as data acquisition unit and can handle up to about 1 KHz signal.

  • PDF

REMOTE MONITORING OF WIND-PHOTOVOLTAIC HYBRID GENERATION SYSTEM USING MOBILE PHONE AND INTERNET (휴대폰과 인터넷을 이용한 풍력-태양광 복합발전 시스템의 원격 모니터링)

  • Xu, Zhenchao;Moon, Chae-Joo;Chang, Young-Hak;Lim, Jung-Min;Kim, Tae-Gon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, a remote monitoring system of wind-photovoltaic hybrid generation system using mobile phone and internet has been developed. Many kinds of data can be acquired, analyzed and saved automatically by this system. The hybrid system is composed of 1[kW] PV with DC/DC converter, battery banks and 5[kW] wind power system with power inductor and AC/DC converter. In addition, wind monitoring sensors, voltage and current meters, current transformers and potential transformers are used as accessory instruments. All of these signals are fed into DAQ (Data Acquisition) board after converting the data which have been processed by many types of converters, dividing circuits and signal conditioning circuits. These data can not only be displayed on a computer, transmitted using the server program to remote computer and saved on a computer as a file day by day but also be sent as a CDMA message. The monitored-data can be downloaded, analyzed and saved from server program in real-time via mobile phone or internet at a remote place. All of the programs were designed with LabVIEW software.

  • PDF

Efficient VLSI Architecture for Lifting-Based 2D Discrete Wavelet Transform Filter (리프팅 기반 2차원 이산 웨이블렛 변환 필터의 효율적인 VLSI 구조)

  • Park, Taegu;Park, Taegeun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.11
    • /
    • pp.993-1000
    • /
    • 2012
  • In this research, we proposed an efficient VLSI architecture of the lifting-based 2D DWT (Discrete Wavelet Transform) filter with 100% hardware utilization. The (9,7) filter structure has been applied and extendable to the filter length. We proposed a new block-based scheduling that computes the DWT for the lower levels on an "as-early-as-possible" basis, which means that the calculation for the lower level will start as soon as the data is ready. Since the proposed 2D DWT computes the outputs of all levels by one row-based scan, the intermediate results for other resolution levels should be kept in storage such as the Data Format Converter (DFC) and the Delay Control Unit (DCU) until they are used. When the size of input image is $N{\times}N$ and m is the filter length, the required storage for the proposed architecture is about 2mN. Since the proposed architecture processes the 2D DWT in horizontal and vertical directions at the same time with 4 input data, the total period for 2D DWT is $N^2(1-2^{-2J})/3$.

Development of Data Acquistion and Processing System for the Analysis of Biophysiological signal (생체신호 처리를 위한 시스템 개발)

  • 이준하;이상학;신현진
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 1992
  • This study describes the design of the biophysiological signal processing analyzer which can collect and analyze the biosignal raw data. System hardware is consisted of the IBM PC AT. pre-amplifier. AID converter, Counter/Timer. and RS-232C processor. Biophysiological signal data were processed by the software digital filter. FFT and graphic processing routine. The tachogram and FFT of the the peak to peak interval time was accomplished by the Graphic user interface software using the biophysiological signal processed data. Using this system. the powerspectrum of the heart rate variability during the long term could be observed. Experimental results of this system approach our purpose. which is improved the cost performance. easy to use. reducing raw-data noise and optimizing model for digital filter.

  • PDF

Design and Development of Meteorological Data Logger

  • Ng, Yin-Yeo;Park, Soo-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.6
    • /
    • pp.671-676
    • /
    • 2010
  • In this paper, an effort has been made to design and develop a meteorological data logger for meteorological purpose. This data logger is proposed to be included various sensor interface that used in weather sensors. Besides, numbers of meteorological process libraries are added into this data logger to make it able to perform as unattended weather monitoring system. Data output of this data logger are also design to support multiple protocol that commonly used in data logger, and several communication devices that commonly used in the market. Each data that logged will be logged together with date and time and able to retrieve via serial port using hyper terminal. It is also configurable via serial port.