• Title/Summary/Keyword: Dark Current

Search Result 369, Processing Time 0.026 seconds

Optical packaging technology and characterization of analog PIN-Photodiode (Analog용 PIN-Photodiode의 광 패키징 기술 및 특성 연구)

  • Lee Chang Min;Kwon Kee Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.3 s.333
    • /
    • pp.17-24
    • /
    • 2005
  • We fabricated PIN-Photodiodes with a single mode fiber for analog communications and analyzed characteristics of the devices. The fabricated PIN-Photodiode shows a bandwidth of 1.5 GHz, a dark current of 20 p4 a capacitance of 0.48 pF, and the responsivity of 0.9 V/W, a second order distortion of -72 dBc. In this paper, we developed a new optical Packaging technology that is aligning in real-time monitoring of both responsivity and IM2 characteristics. As a result responsivity has been improved by 0.03 V/W, and also U has been improved by $3\~5\;dBc$. On the other hand, failure ratio has been reduced by $3.5\%$.

Comparison of digitized radiographic alveolar features with age (연령 변화에 따른 치조골의 디지탈 방사선학적 특성비교)

  • Lee Keon Il
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • The purpose of the present study was to use digital profile image features and digital image analysis of fixed-dimension bone regions, extracted from standardized periapical radiographs of the maxilla, to determine whether differences exist in alveolar bone of younger women(mean age: 59.23±7.34 years) and just menopaused women(mean age: 59.23±7.34). Periapical films were used from two groups of 20 randomly selected women. None of the subjects had a remarkable medical history. To simplify protocol, we chose one interproximal bone area between the maxillary right canine and lateral incisor for study. Ech film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-35lOAF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh LC III computer(Apple Computer, Charlotte, N.C.). Area and profile orientation were selected with a NIMH Image 1.37(NIH Research Services Branch, Bethesda, Md.). Histogram features were extracted from each profile and area. The results of this study indicate that mean pixel intensities didn't differ significantly between two groups and there was a high correlarion-coefficient between digitized radiographic profile features and area features.

  • PDF

Search for Ultra-faint Dwarfs in the Halo of M60, Giant Elliptical Galaxy in Virgo

  • LEE, JEONG HWAN;LEE, MYUNG GYOON;JANG, IN SUNG
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.63.2-63.2
    • /
    • 2016
  • One of the well-known problems in the lambda cold dark matter (${\Lambda}CDM$) models is a missing satellite problem. The slope of the mass function of low mass galaxies predicted by ${\Lambda}CDM$ models is much steeper than that based on the luminosity function of dwarf galaxies in the local universe. This implies that the model prediction is an overestimate of low mass galaxies, or that the current census of dwarf galaxies in the local universe may be an underestimate of dwarf galaxies. Previous studies of galaxy luminosity functions to address this problem are based mostly on the sample of galaxies brighter than Mv ~ -10 in the nearby galaxies. In this study we try to search for ultra-faint galaxies (UFDs), which are much fainter than those in the previous studies. We use multi-field HST ACS images of M60 in the archive. M60 is a giant elliptical galaxy located in the east part of the Virgo cluster, and hosts a large population of globular clusters and UCDs. Little is known about the dwarf galaxies in this galaxy. UFDs are much fainter, much smaller, and have lower surface brightness than normal dwarf galaxies so HST images of massive galaxies are an ideal resource. We present preliminary results of this search.

  • PDF

Preparation and Photoelectrochemical Behavior of Cu2O/TiO2 Inverse Opal Heterojunction Arrays

  • Kim, Hyun-Sik;Lee, Sang-Kwon;Kang, Soon-Hyung
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.149-153
    • /
    • 2012
  • The $Cu_2O/TiO_2$ inverse opal heterojunction arrays were developed by electrochemical deposition of $Cu_2O$ nanoparticles on $TiO_2$ inverse opal arrays. The $Cu_2O$ nanoparticles completely filled the inner pores of $TiO_2$ inverse opal film (prepared by liquid phase deposition with an average thickness of 400 nm) and covered the entire area; exhibiting high crystalline properties of anatase and cubic phase from $TiO_2$ and $Cu_2O$, respectively. From asymmetric current-voltage profile, it was noticeable that a heterojunction was well formed for charge transport from $Cu_2O$ to $TiO_2$ film resulting from the enhanced charge separation yield. In addition, increased photocurrent of 0.19 $mA/cm^2$ (versus 0.08 $mA/cm^2$ under dark condition) was obtained at -0.35 V from the heterojunction structure in the 0.5M $Na_2SO_4$ solution.

진단 X-ray 범위에서의 Plasma Display Panel의 X-ray에 대한 전기적 반응 특성 평가

  • Heo, Eun-Sil;Yun, Min-Seok;Jeong, Jae-Hun;Lee, Yeong-Gyu;Mun, Chi-Ung;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.373-373
    • /
    • 2010
  • 본 논문에서는 Display용 PDP(Plasma Display panel)를 디지털 X-ray Detector로 적용하기 위해 Panel 내 Xe gas와 Ne gas의 비율을 달리하며 X-ray에 대한 기본적인 전기적 반응 특성을 연구하였다. 연구에 사용된 panel 은 상용화된 Display용 PDP를 5inch의 크기로 소형화한 sample을 제작하여 사용하였다. 제작된 sample panel의 구조는 기본적으로 Display용 PDP의 구조와 일치한다. 제작된 Sample panel의 X-선 검출기로서의 전기적 특성을 조사하기 위해 기본적인 전기특성인 Dark current, X-ray sensitivity, 그리고 Linearity를 측정하였다. 측정 결과, 진단 범위에서 충분한 전기적 Sensitivity 보이며, 선형적 특성 또한 우수한 결과를 보이는 등 안정된 전기적 동작특성을 보였다. 이러한 결과로부터 기존에 사용되어오던 Display용 PDP에 새로운 X선 변환층을 추가하고, 효율을 더욱 높일 수 있는 구조 변경을 통하여 상용화된 PDP를 디지털 X-선 검출기로서의 적용 가능성을 확인할 수 있었다.

  • PDF

First Record of the Blenniid Fish Istiblennius dussumieri (Blenniidae, Perciformes) from Japan (일본산 청베도라치과 어류 1미기록종, Istiblennius dussumieri)

  • Lee, Chung-Lyul;Yoshihiko, Machida;Shigeru, Nagatomo
    • Korean Journal of Ichthyology
    • /
    • v.12 no.1
    • /
    • pp.20-24
    • /
    • 2000
  • The blenniid fish, Istiblennius dussumieri (Valenciennes) was reported on the basis of six specimens collected from rocky shores on the Yokonami Peninsula, Kochi Prefecture, southern Japan. This species was characterized by wavy, dusky stripes on its dorsal fin, 14 pectoral fin rays, 38 to 42 vertebrae, branched supraorbital cirrus, finger-like nasal cirrus, seven to ten vertical, dark bands on the body and canines absent on both jaws. Although the occurrence of this species may be due to larval transport by the Kuroshio Current, this is the first record of I. dussumieri from Japan represents a remarkable northern range extension of the species in the western Pacific Ocean.

  • PDF

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

MIRIS 우주관측 카메라 Calibration

  • Park, Yeong-Sik;Lee, Dae-Hui;Jeong, Ung-Seop;Mun, Bong-Gon;Lee, Deok-Haeng;Pyo, Jeong-Hyeon;Park, Gwi-Jong;Park, Seong-Jun;Nam, Uk-Won;Lee, Chang-Hui;Park, Jang-Hyeon;Han, Won-Yong;Lee, Seung-U;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.71-71
    • /
    • 2012
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체이며 우주관측카메라, 지구관측카메라, 전장박스로 구성되어 있다. MIRIS 우주관측 카메라는 0.9-2.0 ${\mu}m$ 영역에서 3.67 deg. ${\times}$ 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. MIRIS는 2월 말에 비행모델 개발을 완료하였고, 향후 위성체와의 조립을 진행하고, 러시아 Dnepr 발사장으로 옮겨 2012년 하반기에 발사 예정이다. MIRIS 우주관측카메라에는 Teledyne PICNIC(256${\times}$256 pixel) array를 사용하였고, Dark current, Linearity, Read-out Noise, Gain, Flat 영상 측정 등의 calibration을 수행하였다. 본 발표에서는 Calibration 결과에 대해 논의 하고자 한다.

  • PDF

Development and Characterization of Finger-type PIN Photodiode for Fluorescence Detection of RNA (RNA 형광 검출을 위한 Finger형 PIN 광다이오드의 제작 및 평가)

  • Kim, Ju-Hwan;Oh, Myung-Hwan;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2004
  • This paper represents the development of high sensitivity photo-sensor for the fluorescence detection in the integrated biological analysis system. The finger-type PIN photodiodes were fabricated as the photo-sensor, and had a high sensitivity ($I_{light}/I_{dark}$ = 8720). The interference filter consisted of $TiO_{2}$ and $SiO_{2}$ was directly deposited on the photodiodes. Deposited filter with 95.5% reflection under 532 nm and 98% transmission over 580 nm exceedingly decreased the magnitude of background signal in the detection. The PDMS micro-fluidic channels are bonded on the photodiode by $O_{2}$ plasma treatment. The detection current was proportional to two primary parameters (light intensity, concentration), and the on-chip detection system could detect fluorescence signals down to 100 nM concentration (LOD = Limit of detection of rhodamine).

ERROR PROPAGATION ANALYSIS FOR IN-ORBIT GOCI RADIOMETRIC CALIBRATION

  • Kang, Gm-Sil;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.92-95
    • /
    • 2008
  • The Geostationary Ocean Color Imager (GOCI) is under development to provide a monitoring of ocean-color around the Korean Peninsula from geostationary platforms. It is planned to be loaded on Communication, Ocean, and Meteorological Satellite (COMS) of Korea. The GOCI has been designed to provide multi-spectral data to detect, monitor, quantify, and predict short term changes of coastal ocean environment for marine science research and application purpose. The target area of GOCI observation covers sea area around the Korean Peninsula. Based on the nonlinear radiometric model, the GOCI calibration method has been derived. The radiometric model of GOCI has been validated through radiometric ground test. From this ground test result, GOCI radiometric model has been changed from second order to third order. In this paper, the radiometric test performed to evaluate the radiometric nonlinearity is described and the GOCI radiometric error propagation is analyzed. The GOCI radiometric calibration is based on onboard calibration devices; solar diffuser, DAMD (Diffuser Aging Monitoring Device). The radiometric model error due to the dark current nonlinearity is considered as a systematic error. Also the offset correction error due to gain/offset instability is considered. The radiometric accuracy depends mainly on the ground characterization accuracies of solar diffuser and DAMD.

  • PDF