• 제목/요약/키워드: Damping efficacy

검색결과 40건 처리시간 0.019초

병진 및 회전 감쇠동흡진기를 사용한 보의 진동저감 (Beam Vibration Suppression with Translational and Rotational Damped Dynamic Vibration Absorbers)

  • 박성규;이시복
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.721-728
    • /
    • 2016
  • The combined rotational and translational dynamic vibration absorbers (DVA) with no dampers for the beam vibration control can effectively isolate the vibration within the external excitation force region. This paper investigates the damping efficacy for the combined rotational and translational dynamic vibration absorbers to impose some robustness to the DVA system for the excitation force frequency variation. The beam is assumed to be subjected to a concentrated harmonic excitation force. The solution to the problem is found based on Galerkin method.

건물의 내진성능을 향상시키기 위한 반능동 동조질량감쇠 시스템 (Structural Vibration Control Using Semiactive Tuned Mass Damper)

  • 문영종;지한록;정형조;이인원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.645-650
    • /
    • 2006
  • This paper presents the results of a study to verify the sufficient control performance of semiactive tuned mass damper and to identify suitable control methods for semiactive tuned mass damper in structural vibration control. In this study, four control algorithms are considered: on-off displacement based groundhook, on-off velocity based groundhook, clipped optimal and maximum energy dissipation algorithm. For semiactive tuned mass damper, MR damper is considered as a controllable damping device and the command voltage is calculated by the control algorithms. Each of the control theory is applied to the three story shear building excited by three earthquakes. The performance of each algorithm is compared with that of conventional tuned mass damper system using evaluation criteria. The simulation results indicate that semiactive tuned mass damper has control efficiency. Among the control algorithms, on-off displacement based control theory shows the best efficacy and robustness.

  • PDF

Seismic protection of base isolated structures using smart passive control system

  • Jung, Hyung-Jo;Choi, Kang-Min;Park, Kyu-Sik;Cho, Sang-Won
    • Smart Structures and Systems
    • /
    • 제3권3호
    • /
    • pp.385-403
    • /
    • 2007
  • The effectiveness of the newly developed smart passive control system employing a magnetorheological (MR) damper and an electromagnetic induction (EMI) part for seismic protection of base isolated structures is numerically investigated. An EMI part in the system consists of a permanent magnet and a coil, which changes the kinetic energy of the deformation of an MR damper into the electric energy (i.e. the induced current) according to the Faraday's law of electromagnetic induction. In the smart passive control system, the damping characteristics of an MR damper are varied with the current input generated from an EMI part. Hence, it does not need any control system consisting of sensors, a controller and an external power source. This makes the system much simpler as well as more economic. To verify the efficacy of the smart passive control system, a series of numerical simulations are carried out by considering the benchmark base isolated structure control problems. The numerical simulation results show that the smart passive control system has the comparable control performance to the conventional MR damper-based semiactive control system. Therefore, the smart passive control system could be considered as one of the promising control devices for seismic protection of seismically excited base isolated structures.

Study on Application of Reinforcement Device to Provide Greater Dynamic Stability for Power Transmission Towers and its Effect

  • Yang, Kyeong-hyeon;Bae, Choon-hee;Jeong, Nam-geun;Kim, Doo-young;Kim, Sung-min;Jang, Yong-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.33-41
    • /
    • 2016
  • To verify that the friction damper used to high buildings as a kind of control technology of wind vibration can reduce dynamic behaviors of PTTs effectively, slip dampers in this paper are proposed to absorb the energy through relatively frictional movement of slip dampers applied to main post of a PTT (Power Transmission Tower) when dynamic displacement of a PTT occurs. The result of dynamic analysis is presented to determine the capacity of the damper system by controlling damping ratio on the resonance condition. It is observed that by installing slip dampers at a PTT the strain amplitudes of the main post caused by wind load are effectively reduced. Therefore it is shown that the proposed damper satisfies the strengthened wind-load design standards, and its efficacy was also validated experimentally by field testing.

힘 상쇄 관측기를 이용한 탄성계 진동의 능동제어 (The active vibration control with force cancelling observer in elastic system)

  • 박영필;이규섭;최봉환
    • 대한기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.1016-1025
    • /
    • 1988
  • 본 연구에서는 애널로그(analog)적 기법으로 진동계의 측정된 변위를 정보로 미지의 외력을 추정하고, 이 추정된 외력을 반대 힘으로 되먹임 시킴으로써 진동을 감 쇠시키는 제어계를 구성하였다.특히 관측기의 매개변수(parameter)들을 전체 계를 안정화시키는 방향으로 결정해 줌으로써 진동계의 매개변수들이 시간에 따라 변하는 경우에도 적용시킬 수 있도록 하였다. 이러한 제어계는 순간순간 변하는 외란을 추 정하여 같은 크기의 반대된 힘으로 되먹임시켜주므로 힘 상쇄 관측기라 한다.

유리분수함수 근사법에 기반한 풍하중을 받는 구조물의 동특성 추정 (Modal Parameter Estimations of Wind-Excited Structures based on a Rational Polynomial Approximation Method)

  • 김상범;이완수;윤정방
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.287-292
    • /
    • 2005
  • This paper presents a rational polynomial approximation method to estimate modal parameters of wind excited structures using incomplete noisy measurements of structural responses and partial measurements of wind velocities only. A stochastic model of the excitation wind force acting on the structure is estimated from partial measurements of wind velocities. Then the transfer functions of the structure are approximated as rational polynomial functions. From the poles and zeros of the estimated rational polynomial functions, the modal parameters, such as natural frequencies, damping ratios, and mode shapes are extracted. Since the frequency characteristics of wind forces acting on structures can be assumed as a smooth Gaussian process especially around the natural frequencies of the structures according to the central limit theorem (Brillinger, 1969; Yaglom, 1987), the estimated modal parameters are robust and reliable with respect to the assumed stochastic input models. To verify the proposed method, the modal parameters of a TV transmission tower excited by gust wind are estimated. Comparison study with the results of other researchers shows the efficacy of the suggested method.

  • PDF

진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가 (Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test)

  • 이용훈;김진우;김재환;엄태성;이상현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.182-192
    • /
    • 2023
  • 본 연구에서는 동적 횡하중을 받는 조적 담장의 내진성능 향상을 위한 ECC(Engineered Cementitious Composite) 자켓의 효과를 실험적으로 검증하였다. 첫째로, 임팩트 해머 시험을 통해 비보강과 ECC로 보강된 조적 담장의 고유진동수와 모드 감쇠비, 변형 형상을 식별하여, 940mm의 비보강 조적담장과 970mm의 ECC 보강 담장이 각각 6.4, 35.3Hz의 고유진동수와 7.0, 5.3%의 감쇠비를 가지는 것을 확인하였다. 둘째로, 진동대를 사용하여 면외방향에 대한 지진파 실험을 수행하였고, El Centro(1940) 지진파를 25%부터 300%까지 스케일링하여 적용하였다. 비보강 조적담장의 경우, 50% 지진하중에서 벽돌과 줄눈 경계에 휨균열이 발생하였고, 다시 30%로 스케일링된 지반운동에서 면외방향으로 전도파괴되었다. 반면에 ECC로 보강된 조적담장은 300%의 지진하중에서도 균열이나 손상 없이 강건한 성능을 유지하였다. 마지막으로, 25~300%의 지반운동에 의한 비보강과 ECC 보강 조적담장의 밑면전단력과 설계기준에 따른 밑면전단력을 비교 및 평가하였다. 그 결과, 재현주기 1,000년의 지진에 대해 비보강 조적담장이 붕괴될 위험이 있는 데 반해, ECC 보강 담장은 4,800년 주기의 지진에도 안전한 것으로 추정되었다.

교통하중에 대한 3차원 하이브리드 면진시스템의 수직 진동성능 평가 (Evaluation of Vertical Vibration Performance of Tridimensional Hybrid Isolation System for Traffic Loads)

  • 이용훈;이상현;허무원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권1호
    • /
    • pp.70-81
    • /
    • 2024
  • 본 연구에서는 진동원으로서 교통하중(고속열차)에 대해 수직 방진기능과 수평 면진기능을 조합한 3차원 하이브리드 면진시스템(Tridimensional Hybrid Isolation System, THIS)을 제안하였고, 고속열차 진동에 대한 THIS의 수직 진동 사용성 개선 효과를 해석적으로 평가하였다. 해석을 위하여 실제 16층의 공동주택을 상용구조해석프로그램의 고유치해석과 침실 바닥판에 대한 펄스 응답 분석을 통해 주요 진동모드를 식별하였고, 이 주요 진동 모드를 가지고 바닥판의 수평과 수직, 회전 자유도를 가지는 16개 층의 골조 모델을 제작하였다. 해석방법은 실제 고속철도가 통행할 때 철로와 인접한 구조물에서 계측한 가속도를 진동원으로 적용하고 THIS의 강성과 감쇠비를 변수로 상태-공간방정식을 이용하여 동적해석을 수행하였다. 그 결과, 기존 구조물의 수직 고유주기 대비 THIS의 수직 주기가 커질수록 층별 바닥판 응답이 저감되기 시작하는 임계 주기비가 다르고, 주기가 5배 이상(0.006 이하의 강성비)일 때 모든 바닥판의 가속도 수준이 비면진 대비 약 70% 이하로 감소하였다. 또한, THIS의 감쇠비에 대한 응답 제어에 미치는 영향이 매우 적은 것으로 나타났다. 마지막으로 THIS에 대한 수직 진동 사용성 개선 효과를 확인하기 위하여 비면진 구조물과 0.006의 강성비와 0.03의 감쇠비를 가지는 THIS가 적용된 구조물에 대하여 1층과 16층 바닥판 가속도를 AIJ, SCI, AISC 진동 사용성 기준에 따라 평가하였고, 기존에 주거지 사용성 기준을 만족하지 못한 데 반해, THIS 적용 후 주거지 사용성 기준을 모두 만족하는 것을 확인하였다.

스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선 (Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System)

  • 정형조;정찬국;최강민;이인원
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.37-46
    • /
    • 2006
  • 본 연구에서는 면진 건물의 내진 성능을 개선하기 위하여 최근 개발된 스마트 수동 제어 시스템을 적용하고 이의 효용성을 수치 모의실험을 통해 검증하였다. 스마트 수동 제어 시스템은 효과적인 반능동 제어 장치로 알려진 MR 감쇠기에 전자기 유도부를 도입하여 응답 변화에 따라 MR 감쇠기로 입력되는 전류를 변화시킴으로써 MR 감쇠기의 감쇠 특성을 조절하는 새로운 개념의 스마트 제진 시스템이다. 스마트 수동 제어 시스템에서 전자기 유도부는 영구자석과 솔레노이드 코일로 구성되며, 기존 스마트 제진 시스템의 계측기, 제어기, 외부 전원장치를 한꺼번에 대체할 수 있다. 면진 건물에 대한 스마트 수동 제어 시스템의 내진 성능을 수치적으로 검증하기 위하여 미국토목학회에서 제시한 면진 건물에 대한 벤치마크 제어 문제를 활용하였다. 스마트 수동 제어 시스템의 제진 성능을 MR 감쇠기를 이용한 기존 스마트 제어 시스템의 성능과 비교하였다. 수치 모의실험 결과를 통해 스마트 수동 제어 시스템이 면진 건물의 내진 성능을 개선하는 데 매우 유용함을 확인하였다.

On the NiTi wires in dampers for stayed cables

  • Torra, Vicenc;Carreras, Guillem;Casciati, Sara;Terriault, Patrick
    • Smart Structures and Systems
    • /
    • 제13권3호
    • /
    • pp.353-374
    • /
    • 2014
  • Recent studies were dedicated to the realization of measurements on stay-cable samples of different geometry and static conditions as available at several facilities. The elaboration of the acquired data showed a a satisfactory efficacy of the dampers made of NiTi wires in smoothing the cable oscillations. A further attempt to investigate the applicability of the achieved results beyond the specific case-studies represented by the tested cable-stayed samples is herein pursued. Comparative studies are carried out by varying the diameter of the NiTi wire so that similar measurements can be taken also from laboratory steel cables of reduced size. Details of the preparation of the Ni-Ti wires are discussed with particular attention being paid to the suppression of the creep phenomenon. The resulting shape of the hysteretic cycle differs according to the wire diameter, which affects the order of the fitting polynomial to be used when trying to retrieve the experimental results by numerical analyses. For a NiTi wire of given diameter, an estimate of the amount of dissipated energy per cycle is given at low levels of maximum strain, which correspond to a fatigue fracture life of the order of millions of cycles. The dissipative capability is affected by both the temperature and the cycling frequency at which the tests are performed. Such effects are quantified and an ageing process is proposed in order to extend the working temperature range of the damper to cold weathers typical of the winter season in Northern Europe and Canada. A procedure for the simulation of the shape memory alloy behavior in lengthy cables by finite element analysis is eventually outlined.