• 제목/요약/키워드: Damper length

검색결과 91건 처리시간 0.02초

Simultaneous optimal damper placement using oil, hysteretic and inertial mass dampers

  • Murakami, Yu;Noshi, Katsuya;Fujita, Kohei;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제5권3호
    • /
    • pp.261-276
    • /
    • 2013
  • Oil, hysteretic and inertial mass dampers are representatives of passive dampers used for smart enhancement of seismic performance of building structures. Since oil dampers have a nonlinear relief mechanism and hysteretic dampers possess nonlinear restoring-force characteristics, several difficulties arise in the evaluation of buildings including such dampers. The purpose of this paper is to propose a practical method for simultaneous optimal use of such dampers. The optimum design problem is formulated so as to minimize the maximum interstory drift under design earthquakes in terms of a set of damper quantities subject to an equality constraint on the total cost of dampers. The proposed method to solve the optimum design problem is a successive procedure which consists of two steps. The first step is a sensitivity analysis by using nonlinear time-history response analyses, and the second step is a modification of the set of damper quantities based upon the sensitivity analysis. Numerical examples are conducted to demonstrate the effectiveness and validity of the proposed design method.

6도체방식 송전선로의 서브스판진동 해석에 관한 연구 (A study on Subspan Oscillation Analysis of 6 Bundle Conductor Transmission lines)

  • 이형권
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.729-736
    • /
    • 1997
  • The subspan oscillation is the most important in bundled transmission lines, which can cause conductor damage and transmission line hardware failures. So it is necessary to analyze the subspan oscillation in details for transmission lines. This paper suggests the basic concept and theoretical analysis method of subspan oscillation for 6 bundle conductor transmission line, which considers wind speed, subspan length and conductor tension. Especially this paper uses a spacer damper model with clamp-arm flexibility and damping characteristics. Theoretical analysis results are proposed.

  • PDF

다전극을 이용한 ER유체 유동모드 가시화에 관한 연구 (A study on visualization about the flow mode of ER fluid using the DME)

  • 이육형
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2010
  • A new flow mode of ER fluid available for controlling the damping force by using DME(Discrete Multi-Electrode) is presented in this study. Various characteristics about the flow of ER fluid through the experiment of ER cluster behavior visualization can be assumed. The pressure in electrode length and voltage division mode is measured. An actuator with a damping effect through DME ER damper will be developed. This damper controls the damping force by using the displacement and velocity of the plant which consists of the various electrode length and voltage modes without a controller in the real system.

고속디이젤 기관의 점성비틀림 진동댐퍼에 관한 연구 (A study on the viscous torsional vibration damper in a high speed diesel engine)

  • 한영출
    • 오토저널
    • /
    • 제4권1호
    • /
    • pp.20-30
    • /
    • 1982
  • Recent diesel engine has achieved high speed running comparable to that of gasoline engine as a speed improvement effort. Consequently, torsional vibration of high-speed diesel engine induced vibration nosise, reduced horsepower and the like. Viscous damper which is thought to be effective in curtailing the torsional vibration was studied over a wide range of speed. In this investigation, a water cooling, 4-cycle high-speed diesel engine(Msx. 3500 rpm)was used for the study. Theoretical analysis was made by assuming the engine to be an ideal equivalent system(length, moment of inertia) i. e. the multi-degree of freedom equivalent torsional vibration system with damper was analyzed. In the analysis, the inertia moment of suitable damper for this experiment was calculated by varying the relative damping coefficient of damper of engine for each damper. Furthermore, in the torsional vibration experiment, the torsional vibration amplitude of the crankshaft system was measured when the engine was equipped with dampers of different moments of inertia and also when the engine was equipped without dampers. The experimental results were compared with the analytical values and were found to be satisfied. The results of this investigation are summarized below; (1) It was found that for the engine equipped with dampers, the torsional vibration amplitude was reduced to about one third of those without dampers. (2) The optimum value of inertia moment of viscous damper for the engine was found to be about Id=1.05(kg.cm.s$^{2}$) (3) The optimum damping coefficient and the ratio of moment of inertia for the engine were found to be about Ca= 850(kg.cm.s), Rd=0.509, respectively (b1 dapmper).

  • PDF

작동기 구조해석 및 제어알고리즘 개발 (Development of control algorism and magnetic analysis of a MR damper)

  • 박창순;송삼삼;이현장;이종준;홍성현;조현무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.254-256
    • /
    • 2008
  • In recent Year were many devices and facilities developed and manufactured. For guarantee of the property of the devices and facilities needs Vibration protecting Technique and the Technique will be developed more and more. Magneto-Rheological damper is one of the nice devices for reducing of Vibration. In this paper magnetic properties of a MR-damper which is developed for reducing of vibration in display manufacture devices will be analysed at variation different air-gap length and current.

  • PDF

Optimal Design of a Squeeze Film Damper Using an Enhanced Genetic Algorithm

  • Ahn, Young-Kong;Kim, Young-Chan;Yang, Bo-Suk
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1938-1948
    • /
    • 2003
  • This paper represents that an enhanced genetic algorithm (EGA) is applied to optimal design of a squeeze film damper (SFD) to minimize the maximum transmitted load between the bearing and foundation in the operational speed range. A general genetic algorithm (GA) is well known as a useful global optimization technique for complex and nonlinear optimization problems. The EGA consists of the GA to optimize multi-modal functions and the simplex method to search intensively the candidate solutions by the GA for optimal solutions. The performance of the EGA with a benchmark function is compared to them by the IGA (Immune-Genetic Algorithm) and SQP (Sequential Quadratic Programming). The radius, length and radial clearance of the SFD are defined as the design parameters. The objective function is the minimization of a maximum transmitted load of a flexible rotor system with the nonlinear SFDs in the operating speed range. The effectiveness of the EGA for the optimal design of the SFD is discussed from a numerical example.

동조액체감쇠기의 진동제어 성능연구 (A Study on Control Performance of Tuned Liquid Damper)

  • 우성식;우운택;정란
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.536-543
    • /
    • 2005
  • This paper presents the results of experimental investigations on the response control performance of tuned liquid damper(TLD). Steel frame building model is used for the experiments. Shaking table is controled by velocity consol. Experimental variables are mass ratios(${\mu}=mass$ of TLD/mass of structure), shape ratio(depth of water/ length of TLD), number of nets(N) and tuned frequency ratio($f_l/f_s$). Results show that the greater the mass ratio is, the better the control performance is. So, it can be concluded that TLD is able to be used as a device of vibration control in the remodeling of existing buildings that are not designed to resist earthquake

  • PDF

댐퍼가 부착된 사장교의 케이블 장력에 관한연구 (A Study on Tension for Cables of a Cable-stayed Bridge Damper is Attached)

  • 박연수;최선민;양원열;홍혜진;김운형
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.609-616
    • /
    • 2008
  • 국가경제력 향상과 함께 바다와 섬에 대한 관심이 높아지면서 육지와 섬, 섬과 섬을 연결하는 해상 장대교량이 많이 건설되고 있다. 장대교량은 현수교, 사장교, 아치교, 트러스교 등으로 대변할 수 있는데 그 중에서도 사장교는 주탑(Pylon)과 케이블(Cable), 보강형(Stiffened Girder)이 조화를 이루면서 외관이 아름다워 매력적인 교량형식의 하나로 최근 많이 계획되고 있다. 장력측정은 케이블에 설치한 가속도 센서로부터 케이블의 고유진동수 변화를 이용하는 간접법인 진동법을 적용하였다. 본 연구에서는 댐퍼 설치 케이블의 유효길이 산정식을 제안하였는데 이는 케이블의 유효길이 변화를 실측치와 해석값을 비교하여 분석한 것으로 기존의 유효길이 산정방법인 댐퍼와 정착단간의 순간격에 의한 것은 최종 케이블 장력값 추정에 있어서 신뢰도가 떨어짐을 확인할 수 있었다. 그러므로 향후 유지관리 단계에서는 본 연구에서 제안한 케이블의 유효길이 산정식을 활용하여 장력을 정확하게 파악하는 것이 케이블의 재긴장 및 교체시기 결정 등에도 합리적인 의사결정 자료로 사용될 수 있을 것이다.

코밍 방열 두께 및 블레이드 방열 유무에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구 (An experimental study on the fireproof performance of fire damper in accordance with insulation conditions on the coaming and blade)

  • 최태진;김정식;최경관;임영수;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.431-437
    • /
    • 2013
  • 본 논문에서는 방화 댐퍼의 H-120 등급 방열성능 확보를 위하여 탄화수소화재 조건에 따른 내화 실험을 수행하였다. 실험체는 댐퍼 블레이드 방열 유무와 코밍 방열재 두께의 변화에 따라 3가지 타입으로 제작 하였으며, 내화실험을 통한 비 노출면 단열재와 코밍 표면 온도를 측정 하였다. 내화실험 결과 댐퍼 블레이드를 방열하지 않은 실험체-1, 2는 각각 21분, 46분경과 방열성능 허용 기준을 초과하였으며, 댐퍼 블레이드를 방열한 실험체-3은 120분 방열성능을 만족하는 것으로 나타났다. 방화 댐퍼 내화 시험 기준에 따른 비 노출면 최소 돌출길이(500 mm) 조건에서 댐퍼 블레이드 방열조건이 방화 댐퍼 내화성능에 큰 영향을 미치는 요인임을 확인할 수 있었다.

A hybrid seismic response control to improve performance of a two-span bridge

  • Heo, Gwanghee;Kim, Chunggil;Jeon, Seunggon;Lee, Chinok;Jeon, Joonryong
    • Structural Engineering and Mechanics
    • /
    • 제61권5호
    • /
    • pp.675-684
    • /
    • 2017
  • In this paper, a hybrid seismic response control (HSRC) system was developed to control bridge behavior caused by the seismic load. It was aimed at optimum vibration control, composed of a rubber bearing of passive type and MR-damper of semi-active type. Its mathematical modeling was driven and applied to a bridge model so as to prove its validity. The bridge model was built for the experiment, a two-span bridge of 8.3 meters in length with the HSRC system put up on it. Then, inflicting the EI Centro seismic load on it, shaking table tests were carried out to confirm the system's validity. The experiments were conducted under the basic structure state (without an MR-damper applied) first, and then under the state with an MR-damper applied. It was also done under the basic structure state with a reinforced rubber bearing applied, then the passive on/off state of the HSRC system, and finally the semi-active state where the control algorithm was applied to the system. From the experiments, it was observed that pounding rather increased when the MR-damper alone was applied, and also that the application of the HSRC system effectively prevented it from occurring. That is, the experiments showed that the system successfully mitigated structural behavior by 70% against the basic structure state, and, further, when control algorithm is applied for the operation of the MR-damper, relative displacement was found to be effectively mitigated by 80%. As a result, the HSRC system was proven to be effective in mitigating responses of the two-span bridge under seismic load.