• 제목/요약/키워드: Damage by Durability

검색결과 385건 처리시간 0.024초

철근이 부식된 철근콘크리트 구조물의 건전도 평가기술 (Integrity Estimation of The RC Members Damaged by Corrosion of Main Rebar)

  • 권대홍;유석형;노삼영
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.141-146
    • /
    • 2007
  • It is necessary to guarantee the safety, serviceability and durability of reinforced concrete structures over their service life. However, concrete structures represent a decrease in their durability due to the effects of external environments according to the passage of time, and such degradation in durability can cause structural degradation in materials. In concrete structures, some degradations in durability increase the corrosion of embedded rebars and also decrease the structural performance of materials. Thus, the structural condition assessment of RC materials damaged by corrosion of rebars becomes an important factor that judges needs to apply restoration. In order to detect the damage of reinforced concrete structures, a visual inspection, a nondestructive evaluation method(NDE) and a specific loading test have been employed. However, obscurities for visual inspection and inaccessible members raise difficulty in evaluating structure condition. For these reasons, detection of location and quantification of the damage in structures via structural response have been one of the very important topics in system identification research. The main objective of this project is to develope a methodologies for the damage identification via static responses of the members damaged by durability. Six reinforced concrete beams with variables of corrosion position and corrosion width were fabricated and the damage detections of corroded RC beams were performed by the optimization and the conjugate beam methods using static deflection. In results it is proved that the conjugate beam method could predict the damage of RC members practically.

AN EXPERIMENTAL INVESTIGATION ON MINIMUM COMPRESSIVE STRENGTH OF EARLY AGE CONCRETE TO PREVENT FROST DAMAGE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Koh, Kyung-Taek;Park, Chun-Jin;Ryu, Gum-Sung;Park, Jung-Jun;Kim, Do-Gyeum;Lee, Jang-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제45권3호
    • /
    • pp.393-400
    • /
    • 2013
  • Concrete undergoing early frost damage in cold weather will experience significant loss of not only strength, but also of permeability and durability. Accordingly, concrete codes like ACI-306R prescribe a minimum compressive strength and duration of curing to prevent frost damage at an early age and secure the quality of concrete. Such minimum compressive strength and duration of curing are mostly defined based on the strength development of concrete. However, concrete subjected to frost damage at early age may not show a consistent relationship between its strength and durability. Especially, since durability of concrete is of utmost importance in nuclear power plant structures, this relationship should be imperatively clarified. Therefore, this study verifies the feasibility of the minimum compressive strength specified in the codes like ACI-306R by evaluating the strength development and the durability preventing the frost damage of early age concrete for nuclear power plant. The results indicate that the value of 5 MPa specified by the concrete standards like ACI-306R as the minimum compressive strength to prevent the early frost damage is reasonable in terms of the strength development, but seems to be inappropriate in the viewpoint of the resistance to chloride ion penetration and freeze-thaw. Consequently, it is recommended to propose a minimum compressive strength preventing early frost damage in terms of not only the strength development, but also in terms of the durability to secure the quality of concrete for nuclear power plants in cold climates.

개폐에 따른 지게차 포크의 내구성에 대한 구조해석 (Structural Analysis on Durability of Forklift due to Opening and Closing Between Forks)

  • 조재웅;한문식
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.199-205
    • /
    • 2013
  • Stress and deformation on forklift happened at loading, unloading or moving freight are studied by structural and fatigue analysis in this study. As model 1 as closing type between forks has lower stress and stain than model 2 at opening type, model 1 has more durability than model 2. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'SAE bracket history' with the severest change of load at model 1 and 2, maximum life is shown with Cycle. Minimum damage with 854 at model 2 becomes much higher than model 1. As the gap between forks becomes open, the damage probability becomes higher. The structural result of this study can be effectively utilized with the safe and stable design of forklift by investigating prevention and durability against its damage.

브레이크 디스크 구조 형상별 내구성 해석 (Durability Analysis by Shape of Brake Disk Structure)

  • 한문식;조재웅
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.36-44
    • /
    • 2013
  • This study investigates life, damage and durability through the analyses of fatigue load and vibration on disk brake models of A, B and C. Maximum equivalent stress is happened at the inside of disk brake on these models. As there are A, B and C models by order of life, model A has the most stable strength on fatigue analysis, The deformations at 3 kinds of models become nearly same on natural frequency analysis. The maximum total deformation and equivalent stress is shown at 1617Hz by harmonic vibration analysis on these models. As there are A, B and C models by order of deformation and stress, model A becomes lowest and safest. This study result can be effectively utilized with the design of brake disk in order to improve durability and prevention against its fatigue damage and vibration.

페달의 내구성에 대한 구조 해석 (Structural Analysis on Durability of Pedal)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제10권4호
    • /
    • pp.88-95
    • /
    • 2011
  • In this study, the deformation, stress, vibration, fatigue life and the probability of damage are analyzed at the pedal applied by the force of 300N. The maximum stress at the lower of pedal is shown as 20.801MPa. And the maximum displacement is 0.85mm at the maximum response frequency as 3800Hz. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'Sample history' with the average stress of 0 to $-10^{5}MPa$ and the amplitude stress of 0 to $10^{5}MPa$, the possibility of maximum damage becomes 0.6%. This stress state can be shown with 5 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study can be effectively improved with the design of pedal by investigating durability against its damage.

타이로드의 구조적 내구성 해석 (Structural Durability Analysis of Tie Rod)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제11권5호
    • /
    • pp.68-75
    • /
    • 2012
  • This study aims at the structural analysis of vibration and fatigue according to the tie rod configuration. The maximum displacement amplitude is happened at 156Hz by harmonic vibration analysis, this tie rod model can be broken as the weakest state. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sine wave' becomes most stable. In case of 'Sine wave' with the average stress of 0MPa and the amplitude stress of 570MPa, the possibility of maximum damage becomes 70%. This stress state can be shown with 140 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study can be effectively utilized with the design on tie rod by investigating prevention and durability against its damage.

트위스트 런 운동기구의 내구성 향상에 관한 해석 (An Analysis on Durability Improvement of Twist Run Exercise Equipment)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제13권5호
    • /
    • pp.116-122
    • /
    • 2014
  • In this study, 2 kinds of twist run models as exercise equipments are compared by durability analyses of fatigue and vibration. Maximum equivalent stresses are shown as 3.3 MPa and 16.6 MPa at the parts of stress concentrations at models 1 and 2. As the values becomes much lower than yield stress of this models, these models are shown to be safe designs. Model 1 becomes stronger than model 2 at natural frequency analysis. Fatigue lives become lowest at four axis parts and one axis part respectively in cases of models 1 and 2. Maximum damage probability at fatigue is shown to be 2.4% near the average stress of 0 in case of model 1 but this probability becomes 0.6 % in case of model 2. Model 1 has the maximum damage possibility 4 times more than model 2 at these states. As the result of this study is applied by the design of twist run, the prevention on fatigue damage and the durability are predicted.

Influence of time-varying attenuation effect of damage index on seismic fragility of bridge

  • Yan, Jialei;Liang, Yan;Zhao, Boyang;Qian, Weixin;Chen, Huai
    • Earthquakes and Structures
    • /
    • 제19권4호
    • /
    • pp.287-301
    • /
    • 2020
  • Fragility as one of the most effective methods to evaluate seismic performance, which is greatly affected by damage index. Taking a multi span continuous rigid frame offshore bridge as an example. Based on fragility and reliability theory, considering coupling effect of time-varying durability damage of materials and time-varying attenuation effect of damage index to analyze seismic performance of offshore bridges. Results show that IDA curve considering time-varying damage index is obviously below that without considering; area enclosed by IDA of 1# pier and X-axis under No.1 earthquake considering this effect is 96% of that without considering. Area enclosed by damage index of 1# pier and X-axis under serious damage with considering time-varying damage index is 90% of that without considering in service period. Time-varying damage index has a greater impact on short pier when ground motion intensity is small, while it has a great impact on high pier when the intensity is large. The area enclosed by fragility of bridge system and X-axis under complete destruction considering time-varying damage index is 165% of that without considering when reach designed service life. Therefore, time-varying attenuation effect of damage index has a great impact on seismic performance of bridge in service period.

포크레인 버켓의 피로 내구성 해석에 대한 연구 (Study on Fatigue Durability Analysis of Poclain Bucket)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제12권2호
    • /
    • pp.8-13
    • /
    • 2013
  • This study analyzes about poclain bucket through fatigue durability analysis. Maximum equivalent stress and total deformation are shown at the lower of bucket and edge part respectively. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'Sample history' with the average stress of -10000Pa to 5000MPa and the amplitude stress of 0 to 6000MPa, the possibility of maximum damage becomes 3%. This stress state can be shown with 5 or 6 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study can be effectively utilized with the design of poclain bucket by investigating prevention and durability against fatigue damage.

내구성 향상을 고려한 R.C조 외벽 보수 시스템의 성능과 그 활용 (제1보 : 열화 요인별 외벽 보수기술) (The Performance and Application of Repair System for the Exterior Wall According to the Durability Improvement in the RC Structure (Part1. Theoretical approach to the repair technic))

  • 권영진;김철호;곽영준;박득곤;최롱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.134-138
    • /
    • 1995
  • The reinforced concrcte structure were once belicved to have permanent durability. However, it is now spoiled by durability failure caused by the corrosion of embeded steel reingorcement carbonation. alkali-aggregate reaction and salt attack Recently. salt damage has been also spreading. Salt damage is found in concrete structures built using seasands or certain admixtures containing calcium chlorides and in coastal structures frequently caught in seawater spray or blown by seawind It is the aim of this study to investigate the performance and application of new repair system for the exterior wall according to the durability improvement in the RC structures.

  • PDF