• 제목/요약/키워드: Damage Measurement

검색결과 1,053건 처리시간 0.031초

Simultaneous active strain and ultrasonic measurement using fiber acoustic wave piezoelectric transducers

  • Lee, J.R.;Park, C.Y.;Kong, C.W.
    • Smart Structures and Systems
    • /
    • 제11권2호
    • /
    • pp.185-197
    • /
    • 2013
  • We developed a simultaneous strain measurement and damage detection technique using a pair of surface-mounted piezoelectric transducers and a fiber connecting them. This is a novel sensor configuration of the fiber acoustic wave (FAW) piezoelectric transducer. In this study, lead-zirconate-titanate (PZT) transducers are installed conventionally on a plate's surface, which is a technique used in many structural health monitoring studies. However, our PZTs are also connected with an optical fiber. A FAW and Lamb wave are simultaneously guided in the optical fiber and the structure, respectively. The dependency of the time-of-flight of the FAW on the applied strain is quantified for strain sensing. In our experimental results, the FAW exhibited excellent linear behavior and no hysteresis with respect to the change in strain. On the other hand, the well-known damage detection function of the surface-mounted PZT transducers was still available by monitoring the waveform change in the conventional Lamb wave ultrasonic path.

화력발전소 주배관 3차원 변위측정시스템 개발 (Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant)

  • 송기욱;현중섭;하정수;조선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

  • PDF

Feedback scope for fault detection and localization

  • Hunsang Jung;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.32.6-32
    • /
    • 2002
  • The damage localization of the structural system using the natural frequency measurement only is proposed. The existing methods use the changes of mode shape, strain mode shape or curvature mode shape before and after the damage occurrence as these shapes carry the geometric information of the structure. Basically, the change of natural frequencies of the structure can be used as the indicator of the damage occurrence but not as the indicator of the damage location as the natural frequency changes does not carry the geometric information of the structure. In this research, the feedback scope method that measures the natural frequency changes of the structure with and without the feedback Ioo...

  • PDF

Electro-Micromechanical 시험법과 음향방출을 이용한 탄소 나노튜브와 나노섬유 강화 에폭시 복합재료의 비파괴적 손상 감지능 (Nondestructive Damage Sensitivity of Carbon Nanotube and Nanofiber/Epoxy Composites Using Electro-Micromechanical Technique and Acoustic Emission)

  • Kim, Dae-Sik;Park, Joung-Man;Lee, Jae-Rock;Kim, Tae-Wook
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.117-120
    • /
    • 2003
  • Electro-micromechanical techniques were applied using four-probe method for carbon nanotube (CNT) or nanofiber (CNF)/epoxy composites with their content. Carbon black (CB) was used to compare with CNT and CNF. The fracture of carbon fiber was detected by nondestructive acoustic emission (AE) relating to electrical resistivity for double-matrix composites test. Sensing for fiber tension was performed by electro-pullout test under uniform cyclic strain. The sensitivity for fiber damage such as fiber fracture and fiber tension was the highest for CNT/epoxy composites, and in CB case they were the lowest compared with CNT and CNF. Reinforcing effect of CNT obtained from apparent modulus measurement was the highest in the same content. The results obtained from sensing fiber damage were correlated with the morphological observation of nano-scale structure using FE-SEM. The information on fiber damage and matrix deformation and reinforcing effect of carbon nanocomposites could be obtained from electrical resistivity measurement as a new concept of nondestructive evaluation.

  • PDF

초음파 주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Frequency Analysis Spectrum Method)

  • 정민화;이상국
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.90-98
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions like high temperature and high pressure for an extended period time. Such material degradation lead to various component faliures causing serious accidents at the plant. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for their preparing creep degraded specimens have been carried out for the purpose of nondestructive evaluation for creep damage which can occur in high-temperature pipelline of fossil power plant. As a result of ultrasonic tests for crept specimens, we confirmed that the high frequency side spectra decrease and central frequency components shift to low frequency bans, and bandwiths decrease as increasing creep damage in backwall echoes.

  • PDF

Results and implications of the damage index method applied to a multi-span continuous segmental prestressed concrete bridge

  • Wang, Ming L.;Xu, Fan L.;Lloyd, George M.
    • Structural Engineering and Mechanics
    • /
    • 제10권1호
    • /
    • pp.37-51
    • /
    • 2000
  • Identification of damage location based on modal measurement is an important problem in structural health monitoring. The damage index method that attempts to evaluate the changes in modal strain energy distribution has been found to be effective under certain circumstances. In this paper two damage index methods using bending strain energy and shear strain energy have been evaluated for numerous cases at different locations and degrees of damage. The objective is to evaluate the feasibility of the damage index method to localize the damage on large span concrete bridge. Finite element models were used as the test structures. Finally this method was used to predict the damage location in an actual structure, using the results of a modal survey from a large concrete bridge.

Structural damage detection using a multi-stage improved differential evolution algorithm (Numerical and experimental)

  • Seyedpoor, Seyed Mohammad;Norouzi, Eshagh;Ghasemi, Sara
    • Smart Structures and Systems
    • /
    • 제21권2호
    • /
    • pp.235-248
    • /
    • 2018
  • An efficient method utilizing the multi-stage improved differential evolution algorithm (MSIDEA) as an optimization solver is presented here to detect the multiple-damage of structural systems. Natural frequency changes of a structure are considered as a criterion for damage occurrence. The structural damage detection problem is first transmuted into a standard optimization problem dealing with continuous variables, and then the MSIDEA is utilized to solve the optimization problem for finding the site and severity of structural damage. In order to assess the performance of the proposed method for damage identification, an experimental study and two numerical examples with considering measurement noise are considered. All the results demonstrate the effectiveness of the proposed method for accurately determining the site and severity of multiple-damage. Also, the performance of the MSIDEA for damage detection compared to the standard differential evolution algorithm (DEA) is confirmed by test examples.

초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제20권1호
    • /
    • pp.18-26
    • /
    • 2000
  • 화력발전소 보일러 고온배관인 주증기관, 헤드 및 증기드럼 등의 설비들은 장시간동안 고온고압의 가혹한 조건으로 운전됨에 따라 크리프손상에 의해 열화되고 있다. 이들 설비의 크리프손상측정에 적용되는 종래의 비파괴기법인 레프리카법, 전기저항법 및 경도법 등은 복잡한 측정절차 및 접근성, 검사결과의 신뢰도 및 측정정도 등 여러가지면에서 단점이 많다. 따라서 본 논문에서는 화력발전소 주요 고온배관에서 발생되는 경년열화인 크리프손상에 대한초음파 측정연구를 수행한 결과로서, 고온배관재료인 Cr-Mo강의 크리프 인공열화재를 대상으로 이들에 대한 크리프손상 상태별 초음과 음속(sound velocity) 및 감쇠(attenuation)의 초음파 신호특성을 평가하였다.

  • PDF

연령이 고려된 양쪽 귀의 가청대역 청력측정에 관한 연구 (On the Audible Band Hearing Measurement of Both Ears Considering Age)

  • 김봉영;배명진
    • 문화기술의 융합
    • /
    • 제7권1호
    • /
    • pp.570-575
    • /
    • 2021
  • 인간은 오감을 풍요롭게 느끼면서 생활하기 때문에 인간의 행복한 삶을 영위하기 위해서는 청력이 손상되지 않도록 주의하여야 한다. 생활환경에서 입게 되는 청력손상은 특정 주파수대역이 먼저 손상되는 부분대역에서 청력손상이 일반적이다. 그러나 청력손상의 초기 통증이 별로 나타나지 않아서 그 증세를 초기단계에는 알아내기가 어렵다. 본 연구에서는 간단한 어플 등을 통해 손쉽고 빠르게 청력손상을 자가 측정할 수 있는 고속 측정법을 제안하였다. 이 방법은 voice soub-band별 이득 보상된 pure tone 9개를 번갈아 양쪽 귀에 들려줌으로써 자신의 청력손상을 스스로 고속 판별하게 된다. 1인당 27초 동안 18번의 톤 펄스를 들려주었을 때, 12명의 피험자들 중에서 1명이 부분청력손상 의심자로 확인되었다. 그리고 피험자들에게 들린 횟수 청력판별법을 알려주니, 실험참가자들 스스로가 자신의 청력손상여부를 바로 판별해 내었다. 이러한 측정방법은 스마트 폰으로 27초 내에 양쪽 귀의 청력을 간단히 판단함으로서 병원에서는 10분 이상 소요되었던 청력측정이 비교적 정확하게 이루어져서, 시간과 비용을 줄이면서 청력건강을 유지할 수 있음을 파악하였다.

대형 컨테이너 선박의 유탄성 실선 계측 데이터 분석 Part II - 피로 손상도 추정 (Full Scale Measurement Data Analysis of Large Container Carrier with Hydroelastic Response, Part II - Fatigue Damage Estimation)

  • 김병훈;최병기;박준석;박성건;기혁근;김유일
    • 대한조선학회논문집
    • /
    • 제55권1호
    • /
    • pp.45-55
    • /
    • 2018
  • Concerns are emerging in marine industry on the additional fatigue damages induced by hydroelasticity, and large container carriers, among others, are considered to be susceptible to this hydroelastic response due to its large size, deck openings and high speed. This study focuses on the fatigue damage estimation of 9,400TEU container carrier based on the full scale measurement data via long-base strain gage installed on the ship. Some correlation analyses have been also done to check whether there was significant torsional response during the voyage. Direct cycle counting method was used to derive stress histogram and the long-term fatigue damage was estimated based upon that analyzed data. It turned out that the fatigue damage of this particular ship during the measurement period increased by more than 60% due to the hydroelastic response of the hull, and main contribution is considered to come from vertical bending mode.