• Title/Summary/Keyword: Damage Effect

Search Result 5,938, Processing Time 0.033 seconds

A Study on the Calculation of Load Resistance Factor of over Tension Anchors by Optimization Design (최적화 설계를 통한 과긴장 앵커의 하중-저항계수 산정 연구)

  • Soung-Kyu Lee;Yeong-Jin Lee;Yong-Jae Song;Tae-Jun Cho;Kang-Il Lee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.17-26
    • /
    • 2023
  • To consider the risk of damage and fracture of P.C strands, the existing post-maintenance system alone has the limitations, hence it is necessary to quantitatively evaluate and predict the deterioration, durability and safety of facilities and establish a reasonable maintenance system considering the asset value of facilities. Therefore, it is worth considering a preventive maintenance plan that allows proactive measures to be taken before a major defect occurs in the temporary anchor. This study devised a preventive over tension method, reviewed its effectiveness through design and field tests, by calculating the resistance factors by performing a reliability-based optimization design. At this time, the over tension anchor method was evaluated using the ratio of the residual tension force after the fracture of P.C strands to the effective tension force before the fracture of P.C strand, followed by the resistance factor calculated by the optimal solution for each random variables using Excel solver and applying it to the limit state equations. As a result of the study, if the over tension ratio is 125% to 130%, the remaining strands showed a high resistance effect even after the fracture of P.C strand. As a result of the optimization design, it was found that it is appropriate to apply the load factor (γ) of 1.25, and the resistance factors of Φ1, Φ2, Φ3 as 0.7, 0.5, 0.6.

A Case Study of the Utilization of Cultural Property in Border Areas led by Local Residents - Focusing on the Horogoru Tong-il Balagi Festival in Wondang-ri, Jangnam-myeon, Yeoncheon-gun - (지역 주민주도를 통한 접경지역 문화유산 활용사례에 관한 연구 - 연천군 장남면 원당리 호로고루 통일바라기 축제를 중심으로 -)

  • LEE Sejin;PARK Kyujin;CHOI Jongtaik;LEE Donghae;KANG Sangsik
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.4
    • /
    • pp.270-286
    • /
    • 2023
  • This article is about the conservation and use cases of Horogoru, a Goguryeo site located in Wondang-ri, Jangnam-myeon, Yeoncheon-gun in Gyoenggi Province. After Horogoru was excavated, it was decided to build a park around it as a way to prevent damage, and also to plant sunflowers to symbolize the sun. Naming the park 'Tong-il Balagi Park', which refers to the wish for unification, local residents and other related organizations jointly opened the site. Afterwards, they looked for ways to utilize the location and park, and chose to hold the 'Tong-il Balagi Festival'. The festival is an event held under the leadership of local residents, which has the effect of promoting both conservation and cultural property, as well as generating economic benefits. In other words, the Yeoncheon-gun, Jangnam-myeon Tong-il Balagi Festival can be said to be an exemplary example of successfully overcoming various disadvantages associated with the border area near the ceasefire line through local residents' own utilization of cultural property.

A Study on the Status of Fine Dust Generated from Construction Waste Intermediate Treatment Plants in Rural Area and Its Impact on Neighboring Areas (농촌지역 건설폐기물 중간처리 사업장에서 발생하는 미세먼지의 발생 현황 및 인근 지역에 미치는 영향 연구)

  • Jang, Kyong-Pil;Park, Ji-Sun;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.25 no.4
    • /
    • pp.9-16
    • /
    • 2023
  • In this study, the status and characteristics of fine dust and its impact on neighboring areas were investigated to proactively respond to the government's environmental regulations expected in the future and to minimize the damage by the fine dust generated at construction waste intermediate treatment plants. In addition, since there are no such plants that can affect the surroundings with no houses or other waste treatment sites nearby, an independently located construction waste intermediate treatment plant was selected to compare the characteristics of fine dust with that from the construction waste intermediate treatment sites located in the downtown area. The conclusions of the study are as follows. (1) The measurement results of PM10 at 4 points in the plant showed that the location where the crushing facility was operating had an elevated level of fine dust at 80㎍/m3 on average and a maximum of 124㎍/m3, and the level rose to 110㎍/m3 at points where vehicles frequent. (2) The PM2.5 measurement results inside the plant showed that the average concentration of the reference point was 16㎍/m3 and the maximum value was 20㎍/m3, which was distributed within the management standard. (3) It was found that the average concentration of PM10 in the nearby area ranged from 28 to 38㎍/m3, which was similar to or lower than 36㎍/m3 of the reference point. Therefore, the concentration of the fine dust generated in the plant had a negligible effect on the increase in concentration of fine dust in nearby areas. (4) The heavy metal contents were measured from the filter paper collected from the plant. The PM10 was found to be about 14 to 26ng/m3, and PM 2.5 was 25 to 28ng/m3, which was the average of domestic atmospheric concentrations. (5) The SEM-EDX analysis results showed that the PM10 contained Si and O around 40% similarly for both. The SiO2, a component of silica occupied the most and C was present as CaCO3, which was assumed to be a limestone component. The remaining components included NaO, Al2O3, and CaO as trace oxides. (6) The SEM-EDX analysis results showed that the PM 2.5 contained 5 to 7% of Cl, which is a chlorine ion, and a small amount of K was detected at 2.51% in the sample from the shutdown plant.

Impact Range Analysis of Small LPG Storage Tank Explosions at Highway Rest Areas (고속도로 휴게소 소형 LPG 저장탱크 폭발에 따른 영향범위 분석)

  • Seung duk Jeon;Soon Beom Lee;Jai Young Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.319-327
    • /
    • 2023
  • This study analyzes the risks of explosions of small LPG storage tanks installed at highway rest areas. For this purpose, the ranges of the effect of thermal radiation and overpressure caused by the BLEVE(Boiling Liquid Expansion Vapor Explosion)and VCE(Vapor Cloud Explosion) of a 2900-kg small LPG storage tank installed at highway rest areas were quantitatively evaluated by applying the Areal Location of Hazardous Atmospheres program. The ranges of influence of the derived explosion overpressure and thermal radiation were found to have a maximum radii of 336 m and 423 m, respectively. The study determined that those within 269 m could be severely injured by an explosion overpressure of 3.5 psi, and fatalities from thermal radiation of 10 kw/m2 could occur within 192 m of the exploded storage tank. The safety management plan for the LPG storage tank was discussed while considering the auxiliary facilities of highway rest areas and the extent of the damage impact. These research results will help improve safety accident prevention regulations considering the environment and facilities of the rest areas as well as the safety management of small LPG storage tanks installed at highway rest areas.

Interpersonal relationship and delinquent behavior among adolescents: With specific focus on parent-child relationship, teacher-student relationship, and relationship with friends (청소년의 인간관계와 일탈행동: 부모자녀관계, 친구관계, 교사학생관계를 중심으로)

  • Young-Shin Park;Uichol Kim
    • Korean Journal of Culture and Social Issue
    • /
    • v.10 no.spc
    • /
    • pp.87-115
    • /
    • 2004
  • This paper examines the influence of interpersonal relationship on delinquent behavior among adolescents. The role that parent-child relationship, teacher-student relationship, and relationship with friends play on delinquent behavior is reviewed. Review of empirical studies reveal the following results. First, adolescents who perceive their parents as being hostile and rejecting are more likely to engage in delinquent behavior. Second, those adolescents with parents, who have low expectations and who are less likely pressure them to succeed academically, are more likely to engage in delinquent behavior. Third, adolescents who feel that they have been abandoned by their parents are more likely to engage in delinquent behavior. Fourth, those adolescents with low social support from parents and teachers and high social support from their friends are more likely to engage in delinquent behavior. Fifth, those students who feel hostility from their teachers, have negative relationship with teachers, and experience greater punishment are more likely to engage in delinquent behavior. The results indicate that punishment can have adverse effect on some adolescents, further damaging the teacher-student relationship. Punishment can further reinforce the existing negative cycle that can increase the likelihood of adolescents engaging in delinquent behavior. The results indicate that a lack of support from parents and teacher leads to low academic and self-regulatory efficacy, which leads to low academic performance, which can results in punishments that could further damage their relationship with their parents and teachers and bring them closer to their friends. Adolescents caught up in this negative cycle are more likely to engage in delinquent behavior. These results indicate the need to reform the relational, social, and cultural environment of adolescents who are engaged in delinquent behavior.

  • PDF

A Numerical Study of Building Orientation Effects on Evacuation Standard in Case of Toxic Gas Leakage (독성 가스 누출 시 건물 방향이 대피 기준에 미치는 영향에 관한 수치 해석 연구)

  • Seungbum Jo
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.12-18
    • /
    • 2023
  • The effective evacuation strategy according to the accident scenario is crucial to minimize human casualties in the event of toxic gas leak accidents. In this study, the effect of the direction of a building and the location of an industrial complex on the increase in indoor concentration and outdoor diffusion was examined under the same leakage conditions, and effective evacuation criteria were established. In addition, the guidelines for building directions were suggested when constructing buildings that would mitigate human damage caused by chemical accidents. Three scenarios where buildings faced the front, side, and rear of the leakage direction were investigated through CFD simulations. The results revealed that when the building faced the industrial complex, both indoor and outdoor average gas concentrations increased significantly, reaching up to 120 times higher than the other two orientations. Moreover, the indoor space was filled with toxic gas substances more than twice in the same time due to the rapid increase of indoor concentration rate. In cases where the building's windows were positioned at the front, toxic gas stagnation occurred around the building due to pressure differences and reduced flow velocities. Based on our findings, the implementation of these guidelines will contribute to safeguarding residents by minimizing exposure to toxic gas during chemical accidents.

Effects of the Daylight Disturbance on the Growth and Yield of Spray Chrysanthemum 'Yellow Cap' and 'Peach PangPang' (일조방해가 스프레이 국화 '옐로우캡'과 '피치팡팡'의 생육 및 수량에 미치는 영향)

  • Yuri Lee;Sang Kun Park
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.4
    • /
    • pp.78-83
    • /
    • 2024
  • This study was carried out to analyze the effect of changes in the light environment caused by the daylight disturbance on the growth, flowering, and cut flower quality of spray chrysanthemums. The spray chrysanthemum 'Yellow Cap' and 'Pitch PangPang' cultivars for cut flowers were artificially shaded to interfere with 66% of sunlight compared to the non-shading, and then the growing and flowering characteristics, and cut flower yield were investigated accordingly. There was no significant difference in the cut flower yield per unit area between the shading and the non-shading treatments. However, the number of days to flowering was 72.1 days for the 'Yellow Cap' and 65.2 days for the 'Pitch PangPang', which were delayed by 14.1 and 8.9 days, respectively, compared to the non-shading light. In the shading treatment, the flower diameter and the number of flowers also decreased by 10% and 15%, and 30% and 28% for both 'Yellow Cap' and 'Pitch PangPang', respectively. The stem length also decreased by 10% and 20%, the stem diameter by 23% and 37%, and fresh weight by 32% and 33%, respectively. The shading treatment delayed the flowering of chrysanthemums and reduced the growth such as flower diameter, number of flowers, and the length and weight of cut flowers. Based on these results, the daylight disturbance by artificial buildings is expected to reduce the productivity and quality of cut flowers by limiting the light intensity needed for chrysanthemum growth, flower bud differentiation, and flower development. Therefore, further research is needed on the rate of decrease in yield and market value according to the degree of shading to relieve damage to chrysanthemum growers caused by the daylight disturbance.

Method to Derive the Optimal Vent Position when Flammable Liquid Leaks Based on CFD (CFD 기반 인화성 액체 누출 시 최적의 환기구 배치 도출 방안)

  • Eun-Hee Kim;Seung-Hyo An;Jun-Seo Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.11-18
    • /
    • 2024
  • If flammable liquid leaks, vapor evaporated from the pool can cause poisoning or suffocation to workers, leading to secondary accidents such as fires and explosions. To prevent such damage, ventilation facilities shall be installed when designing indoor workplaces. At this time, the behavior varies depending on the characteristics of the leaked chemical, so it is necessary to select a suitable vent location according to the material. Therefore, 3D CFD simulations were introduced to derive optimal vent position and ventilation efficiency was quantitatively evaluated by vent position. At this time, assuming a situation in which flammable liquids leak at indoor workplaces to form pools, the concentration of vapor evaporated from pools was compared to derive the optimal vent position. As a result of research on toluene with high vapor density, ventilation efficiency was confirmed to be the highest at the upper supply-lower exhaust, and it is judged that introducing it can achieve about 3.7 times ventilation effect at the same maintenance cost. Through this study, it is expected that the workplace will be able to secure workers' safety by applying simulation results and installing ventilation ports.

Protective effect of Macleaya cordata isoquinoline alkaloids on lipopolysaccharide-induced liver injury in broilers

  • Jiaxin Chen;Weiren Yang;Hua Liu;Jiaxing Niu;Yang Liu;Qun Cheng
    • Animal Bioscience
    • /
    • v.37 no.1
    • /
    • pp.131-141
    • /
    • 2024
  • Objective: This experiment aimed to explore the protective action of dietary supplementation with isoquinoline alkaloids (IA) from Macleaya cordata on lipopolysaccharide (LPS)-induced liver injury in broilers. Methods: Total 216 healthy broilers were selected in a 21-d trial and assigned randomly to the following 3 treatments: control (CON) group, LPS group, and LPS+IA group. The CON and LPS groups were provided with a basal diet, whereas the LPS+IA group received the basal diet supplemented with 0.6 mg/kg Macleaya cordata IA. Broilers in LPS and LPS+IA groups were intraperitoneally injected with LPS (1 mg/kg body weight) at 17, 19, and 21 days of age, while those in CON group were injected with equivalent amount of saline solution. Results: Results showed LPS injection caused systemic and liver inflammation in broilers, inhibited immune function, and ultimately lead to liver injury. By contrast, supplementation of IA ameliorated LPS-induced adverse change in serum parameters, boosted immunity in LPS+IA group. Furthermore, IA suppressed the elevation of hepatic inflammatory cytokines and caspases levels induced by LPS, as well as the expressions of genes related to the toll-like receptor 4 (TLR4)/myeloid differentiation primary response 88 (MyD88)/nuclear factor-kappa B (NF-κB) pathway. Conclusion: Dietary inclusion of 0.6 mg/kg Macleaya cordata IA could enhance immune function of body and inhibit liver damage via inactivating TLR4/MyD88/NF-κB signaling pathway in broilers.

Human Recombinant Apyrase Therapy Protects Against Myocardial Ischemia/Reperfusion Injury and Preserves Left Ventricular Systolic Function in Rats, as Evaluated by 7T Cardiovascular Magnetic Resonance Imaging

  • Ziqian Xu;Wei Chen;Ruzhi Zhang;Lei Wang;Ridong Chen;Jie Zheng;Fabao Gao
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.647-659
    • /
    • 2020
  • Objective: The occurrence of intramyocardial hemorrhage (IMH) and microvascular obstruction (MVO) in myocardial infarction (MI), known as severe ischemia/reperfusion injury (IRI), has been associated with adverse remodeling. APT102, a soluble human recombinant ecto-nucleoside triphosphate diphosphohydrolase-1, can hydrolyze extracellular nucleotides to attenuate their prothrombotic and proinflammatory effects. The purpose of this study was to temporally evaluate the therapeutic effect of APT102 on IRI in rats and to elucidate the evolution of IRI in the acute stage using cardiovascular magnetic resonance imaging (CMRI). Materials and Methods: Fifty-four rats with MI, induced by ligation of the origin of the left anterior descending coronary artery for 60 minutes, were randomly divided into the APT102 (n = 27) or control (n = 27) group. Intravenous infusion of APT102 (0.3 mg/kg) or placebo was administered 15 minutes before reperfusion, and then 24 hours, 48 hours, 72 hours, and on day 4 after reperfusion. CMRI was performed at 24 hours, 48 hours, 72 hours, and on day 5 post-reperfusion using a 7T system and the hearts were collected for histopathological examination. Cardiac function was quantified using cine imaging and IMH/edema using T2 mapping, and infarct/MVO using late gadolinium enhancement. Results: The extent of infarction (p < 0.001), edema (p < 0.001), IMH (p = 0.013), and MVO (p = 0.049) was less severe in the APT102 group than in the control group. IMH size at 48 hours was significantly greater than that at 24 hours, 72 hours, and 5 days after reperfusion (all p < 0.001). The left ventricular ejection fraction (LVEF) was significantly greater in the APT102 group than in the control group (p = 0.006). There was a negative correlation between LVEF and IMH (r = -0.294, p = 0.010) and a positive correlation between IMH and MVO (r = 0.392, p < 0.001). Conclusion: APT102 can significantly alleviate damage to the ischemic myocardium and microvasculature. IMH size peaked at 48 hours post reperfusion and IMH is a downstream consequence of MVO. IMH may be a potential therapeutic target to prevent adverse remodeling in MI.