• Title/Summary/Keyword: Daily Average Amount of Storage

Search Result 20, Processing Time 0.025 seconds

Return flow analysis of paddy field by water balance method (물수지분석 기법에 의한 논에서의 회귀율 조사분석)

  • 정상옥;손성호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.59-68
    • /
    • 2001
  • A water balance analysis was performed for a paddy field neighboring the Dongchang stream, downstream of the Unmun reservoir, which is constructed for the urban water supply. Daily rainfall data were collected and irrigation water flow rate, drainage flow rate, evaportranspiration, infiltration, and piezometeric head were measured in the field. The flow rates were continuously observed by water level logger during the growing season. The evaportranspiration and the infiltration were measured by N-type depletion meter and cylindrical infiltrometer, respectively. PVC pipes with 12mm diameter were used for piezometric head measurement. Total Irrigation and drainage flows were 3,608mm and 1,170mm in 1999, and 3,971mm and 1,548mm in 2000, respectively. The mean and range of the daily infiltration rate were 4.4mm/d and 3.4mm/d to 5.5mm/d in 1999 and 5.1mm/d and 4.1mm/d to 6.5mm/d in 2000, respectively. The net ground water flow including the change of soil water storage was 2,855mm in 1999 and 2,540mm in 2000. The evapotranspiration was 458.3mm in 1999 and 553.5mm in 2000. The range of daily evapotranspiration rate was from 1.6 to 8.7mm/d. The return flow ratio was about 32% in 1999 and 39% in 2000 and three year average was 35% including previous study in 1997. The amount of irrigation water was much higher than design standards or references in this study, This was caused by the inadequate water management practice in the area where water was oversupplied on farmers’ request rather than following sound water management principles.

  • PDF

Development of the Standard Blood Inventory Level Decision Rule in Hospitals (병원의 표준 혈액재고량 산출식 개발)

  • Kim, Byoung-Yik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.195-206
    • /
    • 1988
  • Two major issues of the blood bank management are quality assurance and inventory control. Recently, in Korea blood donation has gained popularity increasingly to allow considerable improvement of the quality assurance with respect to blood collection, transportation, storage, component preparation skills and hematological tests. Nevertheless the inventory control, the other issue of blood bank management, has been neglected so far. For the supply of blood by donation barely meets the demand, the blood bank policy on the inventory control has been 'the more the better.' The shortage itself by no means unnecessitate inventory control. In fact, in spite of shortage, no small amount of blood is outdated. The efficient blood inventory control makes it possible to economize the blood usage in the practice of state-of-the-art medical care. For the efficient blood inventory control in Korean hospitals, this tudy is to develop formulae forecasting the standard blood inventory level and suggest a set of policies improving the blood inventory control. For this study informations of $A^+$ whole bloods and packed cells inventory control were collected from a University Hospital and the Central Blood Bank of the Korean Red Cross. Using this informations, 1,461 daily blood inventory records were formulated.48 varieties of blood inventory control environment were identified on the basis of selected combinations of 4 inventory control variables-crossmatch, transfusion, inhospital donation and age of bloods from external supply. In order to decide the optimal blood inventory level for each environment, simulation models were designed to calculate the measures of performance of each environment. After the decision of 48 optimal blood inventory levels, stepwise multiple regression analysis was started where the independent variables were 4 inventory control variables and the dependent variable was optimal inventory level of each environment. Finally the standard blood inventory level decision rule was developed using the backward elimination procedure to select the best regression equation. And the effective alternatives of the issuing policy and crossmatch release period were suggested according to the measures of performance under the condition of the standard blood inventory level. The results of this study' were as follows ; 1. The formulae to calculate the standard blood inventory level($S^*$)was $S^*=2.8617X(d)^{0.9342}$ where d is the mean daily crossmatch(demand) for a blood type. 2. The measures of performace - outdate rate, average period of storage, mean age of transfused bloods, and mean daily available inventory level - were improved after maintenance of the standard inventory level in comparison with the present system. 3. Issuing policy of First In-First Out(FIFO) decreased the outdate rate, while Last In-First Out(LIFO) decreased the mean age of transfused bloods. The decrease of the crossmatch release period reduced the outdate rate and the mean age of transfused bloods.

  • PDF

Level Shifts and Long-term Memory in Stock Distribution Markets (주식유통시장의 층위이동과 장기기억과정)

  • Chung, Jin-Taek
    • Journal of Distribution Science
    • /
    • v.14 no.1
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose - The purpose of paper is studying the static and dynamic side for long-term memory storage properties, and increase the explanatory power regarding the long-term memory process by looking at the long-term storage attributes, Korea Composite Stock Price Index. The reason for the use of GPH statistic is to derive the modified statistic Korea's stock market, and to research a process of long-term memory. Research design, data, and methodology - Level shifts were subjected to be an empirical analysis by applying the GPH method. It has been modified by taking into account the daily log return of the Korea Composite Stock Price Index a. The Data, used for the stock market to analyze whether deciding the action by the long-term memory process, yield daily stock price index of the Korea Composite Stock Price Index and the rate of return a log. The studies were proceeded with long-term memory and long-term semiparametric method in deriving the long-term memory estimators. Chapter 2 examines the leading research, and Chapter 3 describes the long-term memory processes and estimation methods. GPH statistics induced modifications of statistics and discussed Whittle statistic. Chapter 4 used Korea Composite Stock Price Index to estimate the long-term memory process parameters. Chapter 6 presents the conclusions and implications. Results - If the price of the time series is generated by the abnormal process, it may be located in long-term memory by a time series. However, test results by price fixed GPH method is not followed by long-term memory process or fractional differential process. In the case of the time-series level shift, the present test method for a long-term memory processes has a considerable amount of bias, and there exists a structural change in the stock distribution market. This structural change has implications in level shift. Stratum level shift assays are not considered as shifted strata. They exist distinctly in the stock secondary market as bias, and are presented in the test statistic of non-long-term memory process. It also generates an error as a long-term memory that could lead to false results. Conclusions - Changes in long-term memory characteristics associated with level shift present the following two suggestions. One, if any impact outside is flowed for a long period of time, we can know that the long-term memory processes have characteristic of the average return gradually. When the investor makes an investment, the same reasoning applies to him in the light of the characteristics of the long-term memory. It is suggested that when investors make decisions on investment, it is necessary to consider the characters of the long-term storage in reference with causing investors to increase the uncertainty and potential. The other one is the thing which must be considered variously according to time-series. The research for price-earnings ratio and investment risk should be composed of the long-term memory characters, and it would have more predictability.

Assessing Irrigation Water Supply from Agricultural Reservoir Using Automatic Water Level Data of Irrigation Canal (관개용수로의 자동수위측정 자료를 활용한 농업용 저수지 공급량 산정 및 분석)

  • Bang, Jehong;Choi, Jin-Yong;Yoon, Pureun;Oh, Chang-Jo;Maeng, Seung-Jin;Bae, Seung-Jong;Jang, Min-Won;Jang, Taeil;Park, Myeong Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • KRC (Korea Rural Community Corporation) is in charge of about 3,400 agricultural reservoirs out of 17,240 agricultural reservoirs, and automatic water level gauges in reservoirs and canals were installed to collect reservoir and canal water level data from 2010. In this study, 10-minute water level data of 173 reservoir irrigation canals from 2016 to 2018 are collected, and discharge during irrigation season was calculated using rating curves. For estimation of water supply, irrigation water requirement was calculated with HOMWRS (Hydrological Operation Model for Water Resources System), and the summation of reservoir water storage decrease was calculated with daily reservoir storage data from RAWRIS (Rural Agricultural Water Resource Information System). From the results, the total yearly amount of irrigation water supply showed less than 10% difference than the irrigation water requirement. The regional analysis revealed that reservoirs in Jeollanam-do and Chungcheongnam-do supply greater irrigation water than average. On the contrary, reservoirs in Gyeongsangnam-do and Chungcheongbuk-do supply less than others. This study was conducted with a limited number of reservoirs compared to total agricultural reservoirs. Nevertheless, it can indicate irrigation water supply from agricultural reservoirs to provide information about agricultural water use for irrigation.

Securing Inflows to Reservoir with Low Ratio of Watershed to Paddy Field Areas by Operating Outside Diversion Weir (유역외 보의 연계운영에 의한 유역배율이 작은 저수지의 유입량 확보 가능성)

  • Noh, Jae-Kyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.1
    • /
    • pp.17-28
    • /
    • 2011
  • This study was performed to ascertain the possibility of securing inflows to reservoir with low ratio of watershed to paddy field areas by outside diversion weir. The case of Maengdong reservoir and Samryong diversion weir was selected. Most of inflows to Maengdong reservoir with watershed area of $7.06\;km^2$ and total storage capacity of $1,269{\times}10^4\;m^3$ are filled with intake water from outside Samryong diversion weir. Only using water storage data in Maengdong reservoir from 1991 to 2009, the range of water intake in Samryong diversion weir to Maengdong reservoir was optimized to 0.135~30 mm/d, from which water intake to Maengdong reservoir was $1,672.9{\times}10^4\;m^3$ (70.1 %) and downstream outflow to Weonnam reservoir was $714.4{\times}10^4\;m^3$ (29.9 %). The parameters of DAWAST model for reservoir inflow were determined to UMAX of 313.8 mm, LMAX 20.3 mm, FC 136.8 mm, CP 0.018, and CE 0.007. Inflows to Maengdong reservoir were $427.1{\times}10^4\;m^3$ (20.3 %) from inside watershed, and $1,672.9{\times}10^4\;m^3$ (79.7 %) from outside. Paddy irrigation water requirements were estimated to $1,549{\times}10^4\;m^3$ on annual average. Operation rule curve was drawn by using daily inflow and irrigation requirement data. By securing the amount of inflow to Maengdong reservoir to about 80 % from outside Samryong diversion weir, water supply capacity for irrigation of $1,549{\times}10^4\;m^3/yr$ was analyzed to be enough. Additional water supplies for instream flow were analyzed to $1,412\;m^3/d$ in normal reservoir operation, $36,000\;m^3/d$ in withdrawal limit operation by operation rule curve from October to March of non irrigation period.

Soil Salt Prediction Modeling for the Estimation of Irrigation Water Requirements for Dry Field Crops in Reclaimed Tidelands (간척지 밭작물의 관개용수량 추정을 위한 토양염분예측모형 개발)

  • 손재권;구자웅;최진규
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.2
    • /
    • pp.96-110
    • /
    • 1994
  • The purpose of this study is to develop soil salt prediction model for the estimation of irrigation water requirements for dry field crops in reclaimed tidelands. The simulation model based on water balance equation, salt balance equation, and salt storage equation was developed for daily prediction of sa]t concentration in root zone. The data obtained from field measurement during the growing period of tomato were used to evaluate the applicability of this model. The results of this study are summarized as follows: 1.The optimum irrigation point which maximizes the crop yield in reclaimed tidelands of silt loam soil while maintaining the salt concentration within the tolerance level, ws found to be pF 1.6, and total irrigation requirement after transplanting was 602mm(6.7 mm/day)for tomato. 2.When the irrigation point was pF 1.6, the deviation between predicted and measured salt concentration was less than 4 % at the significance level of 1 7% 3.Since the deviations between predicted and measured values data decrease as the amount of irrigation water increases, the proposed model appear to be more suitable for use in reclaimed tidelands. 4.The amount of irrigation water estimated by the simulation model was 7.2mm/day in the average for cultivating tomato at the optimum irrigation point of pF 1.6.The simulation model proposed in this study can be generalized by applying it to other crops. This, model, also, could be further improved and extended to estimate desalinization effects in reclaimed tidelands by including meteorological effect, capillary phenomenon, and infiltration.

  • PDF

The Profile of Milling Plants in Korea (우리나라 양곡가공공장의 현황분석)

  • 정창주;금동혁;강화석
    • Journal of Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.47-63
    • /
    • 1978
  • This study was conducted to obtain a basic information necessary to assess present rice milling technology in Korea The profiles for milling plants was analyzed by survey work.For the private custom-work mills, which process about 80 percent of domestic rice consumption ,their actual milling test for the identical samples as used for filed mills was conducted. Two rice varieties Japonica and Tongil-type were associated with the experiments. The results are summarized as follows: 1. Analyses for private custom-work mills showed their general aspects as; about 91 percent of the mills belonged to an individual owner ship ; more than 93 percent of the mills was established earlier than 1950 ; about 80 percent of the mills was powered with electric motor; mills having less than two employees were about 75 percent; about 45 percent of the mills provided for warehouse in storing customers cereal grains. 2. The polishers installed in 1,255mills within the surveyed area (7 counties) have been supplied by 44 different domestic manufacturers ;in but about 60 percent of which was supplied by 6major manufacturers. The polishers could be classified into two categories in terms of principles of their polishing actions ;jet-pearler and friction types. About 51 percent of the mills was equipped with the former which has been recognized as giving greater milling recovery than the friction types. 3. Reason for owners of private mills to supplement new machines was due mainly to pgrading their mills to meet the requirements that established by the Government. However, about 60 percent of the mill owners intended to replace with new pearler by their own needs to meet with new high yielding varieties. 4. Processing systems of each previate rice mills surveyed could be classified into three categories, depending upon whether the systems posessed such components as precleaner and paddy separator or not. Only 36.7 percent of mills was installed with both precleanr ad paddy seperrator, 5.0 percent of mills did have neither percleaner nor paddy seperator, and rest of them equipped only one of the two. Hence,it is needed for about 63% of rice miils to be supplemented with these basic facilities to meet with the requirements for the standaized system. 5. Actual milling capacity measured at each field rice mills was shown a wide variation, having range from about 190 to 1,210 kg/hr. The percentages of mills classified according to daily milling capacity based on this hourly capacity were 24.3% for the capacity less than 3 M/T a day; 20.0% for 3-4 M/T; 15.6% for 4-5 M/T; 6.7% for 5-6 M/T; 22.3% for 6-7 M/T; and 11.0% for more than 7 M/T a day. 6. Actual amount of rice processed was about 310 M/T a year in average. About 42% of total milled rice was processed during October to Decembear, which formed a peak demand period for rice mills. The amount of rice milled during January to May was relatively small, but it had still a large amount compared to that during June to September. 7. Utilization rate of milling facility, i. e., percentage of the actual amount of milled rice to the capacity of rice mills, was about 18% on the year round average, about 41% in the peak demand season, and about 10% during June to September. Average number of operating days for mills surveyed was about 250 days a year, and about 21 days a month. 8. Moisture contents of paddy at the time of field mill tests were ranged 14.5% to 19.5% for both Japonica and Tong-i] varieties, majority of paddy grains having moisture level much higher than 1530. To aviod potential reduction of milling recovery while milling and deterioration of milled rice while storage due to these high grain mJisture contents, it may be very important for farmers holding rice to dry by an artificial drying method. 9. Milling recovery of JapJnica varieties in rice mills was 75.0% in average and it was widely ranged from 69.0% to 78.0 % according to mills. Potential increase in milJing recovery of Japonica variety with improvement of mill facilities was estimated to about 1.9%. On the other hand, milling recovery of Tong-il varieties in the field mill tests was 69.8% in average and it ranged from 62% to 77 %, which is much wider than that of Japonica varieties. It is noticed that the average milling recovery of Tong-il variety of 69.8% was much less than that of the Japonica-type. It was estimated th3.t up to about 5.0% of milling recovery for Tong-il variety could be improved by improving the present lo'.ver graded milling technology. 10. Head rice recoveries, as a factor of representing the quality of commercial goods, of Japonica and Tong-il varieties were 65.9% and 53.8% in average, and they were widely ranged from 52% to 73% and from 44% to 65% , respectively. It was assessed that head rice recovery of Japonica varieties can be improved up 3.3% and that of Tong-il varieties by 7.0% by improving mill components and systems.

  • PDF

Practical Radiation Safety Control: (II) Application of Numerical Guidance for the Discharges of Radioactive Gaseous and Liquid Effluents (방사선안전관리 실무: (II) 배기중 및 배수중 배출관리기준의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.61-64
    • /
    • 2014
  • Radioactive materials are in use and have many applications from the generation of electricity to the purposes of research, industry and medicine such as diagnosis and therapy. In the course of their use some of radioactive substances may be discharged into the environment from facilities using the unsealed radioactive materials, which are main artificial sources occurring the public exposure. Discharges are in the form of gases, particles or liquids. This paper provides procedures to estimate the level of the public exposure based on the conservative assumptions and simple calculations in the facility using unsealed liquid sources. They consist of two processes; (1) to calculate maximum concentration of gaseous effluents discharged through the exhaust pipe and average concentration of liquid effluents discharged through the drain of the storage tank, (2) to compare each of them to numerical guidances for the discharges of radioactive gaseous and liquid effluents mentioned in the related notification. For this purpose followings are assumed properly; daily usage, form and dispersion rate of radionuclides, daily amount of radioactive liquid waste and exhaust and drainage equipment. The procedures are readily applicable to evaluate environmental effects by planned effluent discharges from facilities using the unsealed radioactive materials. In addition they may be utilized to obtain practical requirements for radiation safety control necessary for the reductions of the public exposure.

Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve (단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산)

  • 최귀열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.7 no.1
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF

Throughfall, Stemflow and Interception Loss at Pinus taeda and Pinus densiflora stands (테다소나무림과 소나무림에서의 수관통과우량(樹冠通過雨量), 수간유하우량(樹幹流下雨量) 및 차단손실우량(遮斷損失雨量))

  • Min, Hong-Jin;Woo, Bo-Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.502-516
    • /
    • 1995
  • The objective of this study was to estimate throughfall, stemflow, interception loss and net rainfall in relation to rainfall interception, and to understand the factors affecting interception process at Pinus taeda stand and Pinus densiflora stand in the Research Forests of Seoul National University, located in Choosan, Kwangyang, Chollanamdo. 1. The gross rainfall during the period of field observation was 3,107.6mm(average 1,035.9mm/year). Most of the daily rainfall intensity was under 30mm, which was 90% in 1992, 81% in 1993 and 88% in 1994. 2. In this study the throughfall, stemflow, interception loss and net rainfall were expressed separately as a function of gross rainfall. The overall throughfall collected during the period of field observation was 2,432.5mm(78.3%) at Pinus taeda stand and 2,699.6mm at Pinus densiflora stand, out of total rainfall of 3107.6mm. The canopy storage capacity, which was determined by the prediction equation between gross rainfall and throughfall was 1.1mm at Pinus taeda stand and 1.3mm at Pinus densiflora stand. 3. The sums of stemflow from measurement of total rainfall at Pinus taeda stand and Pinus densiflora stand was 227.3mm(7.3%) and 62.7mm(2.0%), respectively. The minimum rainfall causing stemflow was estimated as 7.2mm at Pinus taeda stand and 1.9mm at Pinus densiflora stand. 4. Interception loss accounted for 447.8mm(14.4%) at Pinus taeda stand and 345.3mm(11.1%) at Pinus densiflorra stand. 5. Net rainfall was 2,659.8mm(85.6%) at Pinus taeda stand and 2,762.3mm(88.9%) at Pinus densiflora stand. 6. The rates of throughfall and stemflow increased with increasing the gross rainfall. However, the amounts of throughfall and the stemflow were constant above 30mm at Pinus taeda stand and 50mm at Pinus densiflora stand. The rates of interception loss decreased with increasing the gross rainfall. However, the amount of interception loss was constant above 50mm at Pinus taeda stand and Pinus densiflora stand.

  • PDF