• Title/Summary/Keyword: Dae Hee Lee

Search Result 3,601, Processing Time 0.032 seconds

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

Improved Cerebral Blood Flow and Cerebrovascular Reserve after Carotid Endarterectomy in Patients with Carotid Stenosis and Contralateral Carotid Occlusion: Acetazolamide Stress Brain SPECT Study (반대측 내경동맥 폐쇄를 동반한 경동맥 협착에서 경동맥 내막절제술 후 뇌혈류 및 뇌혈관 예비능의 증가: 아세타졸아마이드 부하 뇌혈류 SPECT 연구)

  • Kim, Jae-Seung;Moon, Dae-Hyuk;Kim, Geun-Eun;Kim, Jong-S.;Kweon, Sun-Uck;Cho, Yong-Pil;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.352-361
    • /
    • 1999
  • Purpose: Carotid endarterectomy nay benefit patients with bilateral carotid stenosis by improving cerebro-vascular hemodynamics of ipsilateral as well as contralateral cerebral hemispheres. We investigated cerebro-vascular hemodynamics after carotid endarterectomy in patients with contralateral carotid occlusion by acetazolamide stress brain SPECT. Materials and Methods: Subjects were 14 symptomatic patients (all men, mean age 66 yrs) with carotid stenosis (>50%) with contralateral carotid occlusion. Acetazolamide stress Tc-99m ECD brain SPECTs were performed within 2 weeks before and after carotid endarterectomy using one day protocol. Cerebral blood flow (CBF) and cerebrovascular reserve (CVR) were assessed visually. In 12 patients, correlation between the patency of proximal anterior cerebral or anterior communicating arteries (A1/A-comm) and the improvement of CBF or CVR after endarterectomy was assessed. Results: Preoperative SPECT showed reduced CBF in 2 ipsilateral and 10 contralateral hemispheres. CVR was reduced in 4 ipsilateral and 9 contralateral hemispheres. Of 12 hemispheres with reduced CBF, 2 hemispheres (16.7%) showed improvement of CBF after endarterectomy. However, reduced CVR was improved in all 4 ipsilateral and 7 of 9 (78%) of contralateral hemispheres after endarterectomy. Three of4 with stenotic Al/A-comm and 4 of 8 with patent A1/A-comm had reduced contralateral CVR. Reduced contralateral CVR improved in all 3 patients with stenotic A1/A-comm and 3 of 4 with patent A1/A-comm. Conclusion: Acetazolamide stress brain SPECT demonstrated improvement of compromised cerebrovascular reserve in not only ipsilateral but also contralateral hemispheres of patients with contralateral carotid occlusion after carotid endarterectomy, and may, therefore, be useful for evaluating cerebral blood flow and cerebrovascular reserve after carotid endarterectomy.

  • PDF

The Nutritive Value of Grains from Barley Cultivars (Wooho, Youngyang, Yuyeon) (청보리 종실의 품종별(우호, 영양, 유연) 사료가치 평가)

  • Kim, Hoi-Yun;Chu, Gyo-Moon;Kim, Sam-Churl;Ha, Ji-Hee;Kim, Jong-Hyun;Lee, Sung-Dae;Song, Young-Min
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.69-78
    • /
    • 2012
  • This study was conducted to investigate the nutritive value of grains from barley cultivars (wooho, youngyang and yuyeon) for substitution of the feedstuffs as corn and soybean meal. In results of proximately analysis, the crude protein concentration was significantly higher (p<0.05) in barley grains than in corn and the crude fat concentration was significantly lower (p<0.05) in barley grains than in soybean meal. The metabolism energy of barley grains was significantly lower (p<0.05) than corn and it was higher (p<0.05) than soybean meal. The in vitro results of pepsin digestibility was significantly higher (p<0.05) in soybean meal than in barley grains and corn, and it was similar barely grains with corn. Barley grains significantly higher (p<0.05) the composition of saturated fatty acids than corn and soybean meal, while lower (p<0.05) the compositions of unsaturated fatty acids and essential fatty acidsin barley grain. The composition of linolenic acid, concentration of lysine and mineral was significantly higher (p<0.05) in barley grains than in corn, while lower (p<0.05) than soybean meal. Therefore, the barley grains is sufficient for substitution of corn. Moreover, the barley grain of yuyeon has high concentrations of crude protein, metabolism energy, lysine and minerals compared with barley grains of wooho and youngyang.

Effect of Supplying Volume and Frequency of Nutrient Solution on Growth and Fruit Quality of Blueberry (블루베리 양액재배시 공급량 및 공급횟수가 수체생육 및 과실품질에 미치는 영향)

  • Cheon, Mi Geon;Lee, Young Suk;Chung, Yong Mo;Kim, Hee Dae;Hong, Kwang Pyo;Kumarihami, H.M. Prathibhani C.;Kim, Jin Gook
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.447-453
    • /
    • 2019
  • In this study, the effect of supplying volume and frequency of a nutrient solution consisted with $NO_3-N$ 4.6, $NH_4-N$ 3.4, $PO_4-P$ 3, K 3, Ca 4.6 and Mg $2.2mmol{\cdot}L^{-1}$ on growth and fruit quality of 'Duke' blueberry was investigated. Three years old 'Duke' blueberry bushes cultivated in containers ($60{\times}80{\times}40cm$) filled with 130L peat moss and 40L pearlite (v/v) were selected for the experiment. The growth containers were mulched with sawdust. Two different volumes (4L and 8L) of nutrient solution was tested at three different supplying frequencies (one time, two times, and three times) per week and the drainage quality of nutrient solution and fruit quality of 'Duke' blueberry was evaluated. The optimal drainage rate for the vegetable cultivation is known to be 20-30%. The results revealed that the average drainage rates of 27% and 29% for the nutrient solution supplied in 'Duke' blueberry growth medium at 4L, 2 times/7 days and 4L, 3 times/7days, respectively. The highest shoot diameter (4.2mm) and shoot length (31cm) of 'Duke' blueberry was recorded with the 8L of nutrient solution supplied at 3 times per 7 days. According to the analysis of inorganic components in the drainage of nutrient solution, there was a tendency of absorbing nitrogen at the early stage of growth. The supplying volume and frequency of nutrient solution was not significantly affected on 'Duke' blueberry fruit weight, soluble solids content, and titratable acidity. The highest yield per bush (2.7kg) was recorded for the nutrient solution supplied with 4L at three times per 7 days, while the 4L nutrient solution supplied at one time per 7 days resulted the lowest yield of 1.4kg per bush. Consequently, the tested nutrient solution can be applied for the 'Duke' blueberry bushes with the volume of 4L at three times per week for the better crop growth.

A Study on Skin Status with Acoustic Measurements of Skin Friction Noise (피부 마찰 소음 측정을 통한 피부 상태 연구)

  • Chang, Yun Hee;Seo, Dae Hoon;Koh, A Rum;Kim, Sun Young;Lim, Jun Man;Han, Jong Seup;Lee, Sang Hwa;Park, Sun Gyoo;Kim, Yang Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Efficacy of cosmetics has been mainly evaluated by qualitative and quantitative methods based on visual sense, tactile sense and skin structure until now. In this study, we suggested a novel evaluation method for skin status based on sound; measuring and analyzing the rubbing noise generated by applying cosmetics. First, the rubbing noise was measured at a close range by a high-sensitivity microphone in anechoic environment, and the noises were analyzed by 1/3 octave band analysis in frequency-domain. Three conditions, 1) before washing, 2) after washing and 3) after application of cosmetics, were compared. As a result, sound pressure level (SPL) of rubbing noise after washing was larger than that of before washing, and the SPL of rubbing noise after cosmetic application was the smallest. Furthermore, the energy of rubbing noise after application was higher than that of the before and after washing conditions in a low frequency band (lower than 2 kHz region). Conversely, the energy of rubbing noise after application was much lower than the others in a high-frequency band (upper than 2 kHz region). This change of energy distribution was described as a balloon-skin model. High SPL in the low frequency region after the cosmetic applications was due to the increase of "flexibility index", while SPL in the high frequency region significantly decreased because of the attenuation which is related to "softness index". Therefore, we developed two indices based on the spectrum-energy difference for evaluating skin conditions. This proposed method and indices were verified via skin flexibility and roughness measurement using cutometer and primos respectively. These results suggest that acoustic measurement of skin friction noise may be a new skin status evaluation method.

Studies on the Soil Properties and Fertilizer Recommendation for Grass Lands to be Established (산지초지(山地草地) 조성대상지(造成對象地) 토양특성(土壤特性)과 시비추천(施肥推薦))

  • Lee, Hyub-Sung;Hur, Bong-Koo;Yoon, Kwan-Hee;Son, Eung-Ryong;Um, Ki-Tae;Noh, Dae-Chul;Kim, Young-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.4
    • /
    • pp.301-306
    • /
    • 1989
  • For the agricultural utilization of Korean forest land resources, which constitutes most of country, the distribution of environment and soil physico-chemical properties of establishable grass lands were clarified. The surveyed data were analized for the reasonable utilization and management of establishable grass land. The results were as follows ; 1. About 50.2% of the grass lands to be established were located under the 200m in altitude. The higher the altitude was, the more the organic matter content. 2. Tall type grass species such as Miscanthus purpurascens, Purple eulalia, and Themeda Japonica covered 71.3% of the natural vegetation in the soils of grass land to be established. 3. The extent of sandy and clayey soils which might be limited in the establishment of grassland was only 3.3%, meanwhile majority of the soils were in the favourable condition for grassland that is about 94% have more than 20cm in available soil depth and about 60.5% of the soils have less than 10% of gravels and stones in the soil profiles. 4. The chemical properties of the prearranged grassland soils were worse than the established grasslands, especially in the content of available $P_2O_5$. 5. The amount of fertilizer recommended for meadow were 286kg of nitrogen per hectare, 271kg of phosphorus, 224kg of potassium and 2040kg of calcium per hectare, but for grazing land were 201, 204, 136 and 1920kg/ha respectively.

  • PDF

The Carboxyl-terminal Tail of a Heterotrimeric Kinesin 2 Motor Subunit Directly Binds to β2-tubulin (Heterotrimeric Kinesin 2 모터 단백질의 Carboxyl-말단과 β2-tubulin의 결합)

  • Jeong, Young Joo;Park, Sung Woo;Kim, Sang-Jin;Lee, Won Hee;Kim, Mooseong;Urm, Sang-Hwa;Seog, Dae-Hyun
    • Journal of Life Science
    • /
    • v.29 no.3
    • /
    • pp.369-375
    • /
    • 2019
  • Microtubules form through the polymerization of ${\alpha}-$ and ${\beta}-tubulin$, and tubulin transport plays an important role in defining the rate of microtubule growth inside cellular appendages, such as the cilia and flagella. Heterotrimeric kinesin 2 is a molecular motor member of the kinesin superfamily (KIF) that moves along the microtubules to transport multiple cargoes. It consists of two motor subunits (KIF3A and KIF3B) and a kinesin-associated protein 3 (KAP3), forming a heterotrimeric complex. Heterotrimeric kinesin 2 interacts with many different binding proteins through the cargo-binding domains of the KIF3s, but these binding proteins have not yet been specified. To identify these proteins for KIF3A, we performed yeast two-hybrid (Y2H) screening and found a specific interaction with ${\beta}2-tubulin$ (Tubb2), a microtubule component. Tubb2 was found to bind to the cargo-binding domain of KIF3A but did not interact with KIF3B, KIF5B, or kinesin light chain 1 in the Y2H assay. The carboxyl-terminal region of Tubb2 is essential for interaction with KIF3A. Other Tubb isoforms, including Tubb1, Tubb3, Tubb4, and Tubb5, also interacted with KIF3A in the Y2H screening. However, ${\alpha}1-tubulin$ (Tuba1) did not interact with KIF3A. In addition, an antibody to KIF3A specifically co-immunoprecipitated the KIF3B and KAP3 associated with Tubb2 from mouse brain extracts. In combination, these results suggest that a heterotrimeric kinesin 2 motor protein is capable of binding to tubulin and may transport it in cells.

Incidence of Viral Diseases on Solanaceae Crops in Gangwon Province (강원지역 가지과 작물 바이러스 발생현황)

  • Won, Heon-Seop;Park, Dong-Kwon;Kwon, Soon-Bae;Jo, Sun-Ok;Kang, Sung-Hee;Lee, Jae-Hong;Hwang, Se-Jeong;Jeong, Tae-Sung;Kim, Mi-Kyeong;Choi, Hong-Soo;Hong, Dae-Ki
    • Research in Plant Disease
    • /
    • v.25 no.1
    • /
    • pp.22-28
    • /
    • 2019
  • This study researched the current occurrence status of viral diseases of solanaceous crops in the main production areas of Gangwon region, for four years from 2014 to 2018. From 2014 to 2018, in eight cities and counties including Chuncheon, CMV, BBWV2, PMMoV, TSWV, and PVY occurred in chilli peppers. In case of tomato, the research was performed in 2017 and 2018 while TSWV and TYLCV were verified in Chuncheon, Hoengseong, and Cheorwon. Especially, TYLCV occurred in Chuncheon region for the first time in 2017, which was verified in 2018. Lastly, the current occurrence status of viral diseases of bell peppers was researched in seven cities and counties like Gangneung, Hoengseong, and Cheorwon from 2015 to 2018. In the results, CMV, BBWV2, PMMoV, PepMoV, and TSWV were verified in bell peppers of Gangwon region. During the research period, there were no crops suspected or infected by BWYV, so that it is judged that there is no villiferous or infected aphid by this virus in Gangwon-do. Such results of this study could be used as the basic data for the stable production of crops through the early prevention of plant diseases occurring in the solanaceous crops of Gangwon region.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.