• 제목/요약/키워드: DSP isolation

검색결과 15건 처리시간 0.109초

Three new okadaic acid derivatives isolated from a benthic dinoflagellate Prorocetrum lima

  • Semin Moon;Dong Han Choi;Yeonjung Lee;Jung-Rae Rho
    • 한국자기공명학회논문지
    • /
    • 제28권3호
    • /
    • pp.25-31
    • /
    • 2024
  • Toxins produced by marine toxigenic algae have garnered growing attention due to their detrimental impacts on marine ecosystem, aquaculture, and human health. Among these, diarrhetic shellfish poisoning (DSP) toxins, such as okadaic acid (OA), are of particular concern. In this study, we report the successful isolation and structural elucidation of three new derivatives of OA from the marine dinoflagellate Prorocentrum lima. These newly identified compounds, OA-2Me-C7, OA-2-Me-C8, and OA-1-Me-C8, were characterized through a comprehensive series of NMR experiments, combined with structural comparisons to the well-known OA. The identification of these derivatives contributes to the expanding knowledge of DSP toxin diversity and provides new insights into the structural variations of these harmful algal toxins.

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

압전세라믹을 이용한 능동진동제어장치의 개발 (Development of the Active Vibration Absorber Using Piezoelectric Actuators)

  • 곽명훈;허석;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.476-481
    • /
    • 2001
  • This research is concerned with development of the active vibration absorber using piezoelectric actuators. This active isolation system consists of a-pairs of PZT actuators bonded on a S-shaped aluminum plate and the passive damping material. The active system is connected to the passive system in series. In this paper, one of the popular control techniques which have been successfully applied to the smart structure is the Positive Position Feedback(PPF) control. The digital PPF control lows downloaded to the DSP chip and a main program, which runs SISO PPF algorithm. The structure and dynamic characteristics of the proposed active vibration isolation system and described in detail. To demonstate the effectiveness of the active vibration control, the PPF controller is first employed. Experimental results show that the active vibration isolation is possible by means of the proposed system.

  • PDF

DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구 (A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP)

  • 서효룡;박영길;김종현;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

Broadband polarimetric Microstrip Antennas for Space-borne SAR

  • Hong, Lei;Qunying, Zhang;Guang, Fu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.465-470
    • /
    • 2002
  • A novel phased array antenna system for space-borne polarimetric SAR is proposed and completed in this paper.The antenna system assures polarimetric and multi-mode capability of SAR. It has broadband, high polarization isolation and high port to port isolation. The antenna system is composed of broadband polarimetric microstrip antenna, T/R modules and multifunction beam controller nit. The polarimetric microstrip antenna has more than 100MHz bandwidth at L-band with -30dB polarization isolation and high port to port isolation. The microstrip element and T/R module's structure and characteristics, the subarray's performances measuring results are presented in detail in this paper. A design scheme on beam controller of the phased array antenna is also proposed and completed, which is based on Digital Signal Processing (DSP) chip -TMS320F206. This beam controller unit has small size and high reliability compared with general beam controller. In addition, the multifunction beam controller unit can acquire and then send the T/R module's working states to detection system in real time.

  • PDF

영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구 (A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor)

  • 김경화;최동욱;구본관;정인성
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.40-51
    • /
    • 2009
  • 인버터 스위치의 개당 혹은 인버터와 모터 터미널의 분리로 인해 발생하는 고장을 해석하고 진단 알고리즘의 시험 평가를 위해 효과적으로 사용할 수 있는 영구자석 동기전동기 구동 인버터의 개방 고장에 의한 제어 특성해석 및 고장모델이 제시된다. 기존의 전동기의 해석과 제어에 많이 사용되는 dq 모델은 상전압 모델을 변환한 것으로 고장 상황에서는 3상평형 조건이 성립하지 않기 때문에 개방 회로의 입력 전압을 구하기가 쉽지 않아 고장 모델의 해석을 위해 직접 사용하기 어렵다. 이를 해결하기 위해 스위치 개방에 따른 전통기의 선전압 관계를 이용한 인버터의 고장 모델이 제안되고 제안된 고장모델의 타당성을 입증하기 위해 시뮬레이션이 수행된다. 전체 시스템이 DSP TMS320F28335에 의해 구현되어 동일 고장 조건에서의 비교 실험과 특성 해석이 수행된다.

직접토크제어 유도전동기의 센서 이상허용 제어 (A Fault-Tolerant Scheme for Direct Torque Controlled Induction Motor Drives)

  • 류지수;이기상
    • 전력전자학회논문지
    • /
    • 제7권4호
    • /
    • pp.366-376
    • /
    • 2002
  • 본 논문에서는 직접토크제어 유도전동기 구동시스템의 고 신뢰성 운전을 위한 센서이상 검출식별 및 이상허용제어에 관한 실험적 연구 결과를 기술한다. 주요 내용은 센서이상 해석 결과의 실험적 검증과 이상검출식별 시스템의 설계, 이상허용제어기의 구현 및 실험적 성능 고찰이다. 적용된 센서이상 검출식별기법은 관측기기반 기법이며 기존의 다중 관측기 기법과 달리 한 개의 관측기에 의해 검출식별정보를 발생하므로 실시간 적용이 용이하다. 제안된 시스템의 성능을 검증하기 위하여 2.2kW 유도전동기를 대상으로 직접토크제어 기법을 이용한 속도제어시스템을 설계하였다. 이상허용제어를 위한 시스템의 하드웨어는 고성능 DSP인 TMS320VC33을 이용한 제어보드와 IPM을 이용한 전력회로로 구성된다. 다양한 센서이상에 대한 실험결과, 설계된 시스템의 검출식별 및 이상허용 제어 성능이 매우 우수함을 확인하였다.

NBI용 필라멘트 전원공급 장치를 위한 풀-브리지 DC/DC 컨버터 (Full-Bridge DC/DC Converter for NBI Filament Power Supply)

  • 전범수;이세형;이희준;신수철;이승교;원충연
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.32-39
    • /
    • 2011
  • FPS(Filament Power Supply), one of the KSTAR NBI(Neutral Beam Injections) is implemented by full-bridge DC/DC converter. NBI heating device for KSTAR(1.5MW) is developed for heating an ion source of plasma in KSTAR tokmak. The full-bridge DC/DC converter is applied to FPS for isolation with input and output. And FPS is operated with PWM control method which is the most usual method. In this paper, NBI FPS of 4.8kW is simulated by using the PSIM 6.0. And the full-bridge DC/DC converter using IGBTs is fabricated to demonstrate it. The processor DSP 28335 is implemented for digital control.

c-CMG Cluster for Small Satellites

  • Lee, Seung-Mok;Seo, Hyun-Ho;Rhee, Seung-Wu
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권1호
    • /
    • pp.105-114
    • /
    • 2007
  • This article presents the details of a designed control moment gyroscope (CMG) with a constant speed momentum wheel and one-axis-gimbal, and its experimental results performed at Korea Aerospace Research Institute. The CMG which is able to produce a torque of lOO mNm per each, is mounted in a pyramid configuration with four SGCMGs. Each CMG test and a single axis maneuver test with four-CMG cluster configuration are performed to confirm their performance on a ground-test facilities consisted of three major parts: a vibration isolation system, a dynamic force plate (Kistler sensor), and a DSP board. These facilities provide the accurate data of three axial and torques from the control moment gyro. Details of the CMG experimental results are presented with discussion of the experimental errors. The experimental data are compared with theoretical results and both results are used to verify their performance specifications.

NBI용 필라멘트 전원공급장치를 위한 풀-브릿지 DC/DC 컨버터 (Full-Bridge DC/DC Converter for NBI Filament Power Supply)

  • 임희성;이세형;전범수;이승교;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.485-486
    • /
    • 2010
  • FPS(Filament Power Supply), one of the KSTAR NBI (Neutral Beam Injections) is implemented by full-bridge DC/DC converter. NBI heating device for KSTAR(1.5MW) is developed for heating an ion source of plasma in KSTAR tokmak. The full-bridge DC/DC converter is applied to FPS for isolation with input and output. And FPS is operated with PWM control method which is the most usual method. In this paper, NBI FPS of 4.8kW is simulated by using the PSIM 6.0. And the full-bridge DC/DC converter using IGBTs is fabricated to demonstrate it. The processor DSP 28335 is implemented for digital control.

  • PDF