• Title/Summary/Keyword: DSA system

Search Result 61, Processing Time 0.021 seconds

Effects of Motivational Activation on Processing Positive and Negative Content in Internet Advertisements

  • Lee, Seungjo;Park, Byungho
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.517-526
    • /
    • 2012
  • This study investigated the impact of individual differences in motivational reactivity on cognitive effort, memory strength (sensitivity) and decision making (criterion bias) in response to Internet ads with positive and negative content. Individual variation in trait motivational activation was measured using the Motivational Activation Measurement developed by A. Lang and her colleagues (A. Lang, Bradley, Sparks, & Lee, 2007). MAM indexes an individual's tendency to approach pleasant stimuli (ASA, Appetitive System Activation) and avoid unpleasant stimuli (DSA, Defensive System Activation). Results showed that individuals higher in ASA exert more cognitive effort during positive ads than individuals lower in ASA. Individuals higher in DSA exert more cognitive effort during negative ads compared to individuals lower in DSA. ASA did not predict recognition memory. However, individuals higher in DSA recognized ads better than those lower in DSA. The criterion bias data revealed participants higher in ASA had more conservative decision criterion, compared to participants lower in ASA. Individuals higher in DSA also showed more conservative decision criterion compared to individuals lower in DSA. The theoretical and practical implications are discussed.

  • PDF

EC-DSA Implementation using Security SoC with built-in ECC Core (ECC 코어가 내장된 보안 SoC를 이용한 EC-DSA 구현)

  • Yang, Hyeon-Jun;Shin, Kyung-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.63-65
    • /
    • 2021
  • This paper describes an integrated H/W-S/W implementation of elliptic curve digital signature algorithm (EC-DSA) using a security system-on-chip (SoC). The security SoC uses the Cortex-A53 APU as CPU, and the hardware IPs of high-performance elliptic curve cryptography (HP-ECC) core and SHA3 (secure hash algorithm 3) hash function core are interfaced via AXI4-Lite bus protocol. The signature generation and verification processes of EC-DSA were verified by the implementation of the security SoC on a Zynq UltraScale+ MPSoC device.

  • PDF

Performance Analysis of Dynamic Spectrum Allocation in Heterogeneous Wireless Networks

  • Ha, Jeoung-Lak;Kim, Jin-Up;Kim, Sang-Ha
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.292-301
    • /
    • 2010
  • Increasing convergence among heterogeneous radio networks is expected to be a key feature of future ubiquitous services. The convergence of radio networks in combination with dynamic spectrum allocation (DSA) could be a beneficial means to solve the growing demand for radio spectrum. DSA might enhance the spectrum utilization of involved radio networks to comply with user requirements for high-quality multimedia services. This paper proposes a simple spectrum allocation algorithm and presents an analytical model of dynamic spectrum resource allocation between two networks using a 4-D Markov chain. We argue that there may exist a break-even point for choosing whether or not to adopt DSA in a system. We point out certain circumstances where DSA is not a viable alternative. We also discuss the performance of DSA against the degree of resource sharing using the proposed analytical model and simulations. The presented analytical model is not restricted to DSA, and can be applied to a general resource sharing study.

Quick Semi-Buddy Scheme for Dynamic Storage Allocation in Real-Time Systems (실시간 시스템에서의 동적 스토리지 할당을 위한 빠른 수정 이진 버디 기법)

  • 이영재;추현승;윤희용
    • Journal of the Korea Society for Simulation
    • /
    • v.11 no.3
    • /
    • pp.23-34
    • /
    • 2002
  • Dynamic storage allocation (DSA) is a field fairly well studied for a long time as a basic problem of system software area. Due to memory fragmentation problem of DSA and its unpredictable worst case execution time, real-time system designers have believed that DSA may not be promising for real-time application service. Recently, the need for an efficient DSA algorithm is widely discussed and the algorithm is considered to be very important in the real-time system. This paper proposes an efficient DSA algorithm called QSB (quick semi-buddy) which is designed to be suitable for real-time environment. QSB scheme effectively maintains free lists based on quick-fit approach to quickly accommodate small and frequent memory requests, and the other free lists devised with adaptation upon a typical binary buddy mechanism for bigger requests in harmony for the .improved performance. Comprehensive simulation results show that the proposed scheme outperforms QHF which is known to be effective in terms of memory fragmentation up to about 16%. Furthermore, the memory allocation failure ratio is significantly decreased and the worst case execution time is predictable.

  • PDF

An Experimental Study on the Cause of Signal Inhomogeneity for Magnetic Resonance Angiography Using Phantom Model of Anterior Communicating(A-com) Artery (전교통동맥 모형을 이용한 자기공명혈관촬영술의 신호 불균일에 관한 실험적 연구)

  • Yoo, Beong-Gyu;Chung, Tae-Sub
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • Aneurysm-mimicking findings were frequently visualized due to hemodynamical causes of dephasing effects around area of A-com artery during magnetic resonance angiography(MRA) and these kind of phenomena have not been clearly known yet. We investigated the hemodynamical patterns of dephasing effect around area of the A-com artery that might be a cause of false intracranial aneurysms on MRA. For experimental study, We used hand-made silicon phantoms of the asymmetric A-com artery as like a bifurcation configuration. In a closed circulatory system with UHDC computer driven cardiac pump system. MRA and fast digital subfraction angiography(DSA) involved the use of these phantoms. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF) and DSA of Phantoms constructed from an automated closed-type circulatory system filled with glycerol solution [circulation fluid(glycerol:water = 1:1.4)]. These findings were then compared with those obtained from computational fluid dynamic(CFD) for inter-experimental correlation study. Imaging findings of MRA, DSA and CFD on inflow zone according to the following: a) MRA demonstrated high signal intensity zone as inflow zone on silicon phantom; b) Patterns of DSA were well matched with MRA on trajectory of inflow zone; and c) CFD were well matched with MRA on the pattern of main flow. Imaging findings of MRA. DSA and CFD on turbulent flow zone according to the following: a) MRA demonstrated hyposignal intensity zone at shoulder and axillar zone of main inflow; b) DSA delineated prominent vortex flow at the same area. The hemodynamical causes of signal defect, which could Induce the false aneurysm on MRA, turned out to be dephasing effects at axilla area of bifurcation from turbulent flow as the results of MRA, DSA and CFD.

  • PDF

Efficient Re-Establishment Mechanism of Diameter Security Association lost in MIP Application (MIP 환경에서의 Diameter Security Association 정보 분실시의 재설정 기법)

  • 유희종;김말희;김현곤
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.13 no.5
    • /
    • pp.39-48
    • /
    • 2003
  • AAA(Authentication, Authorization, Accounting) protocol is a framework that propose functions of AAA on multiple networks and platforms. AAA protocol is extending from previous RADIUS protocol to Diameter protocol. There are some Diameter applications for variety purpose. Diameter CMS Application makes Diameter messages more secure by using PKI. Diameter CMS Application establish DSA(Diameter Security Association) for end to end security. However the Application has some problems to establish DSA(Diameter Security Association), which can make Diameter system unstable. If one system lose DSA information for some system error - for example, reboot -, the secure communication between two nodes may not be possible. At the application such as MIP, even user registration can't be done. In this paper, we propose a mechannism for DSA re-establishment, and also show the result of the implementation.

An Efficient Method Defeating Blackmailing Using Blind XTR-DSA Scheme (블라인드 XTR-DSA 스킴을 이용해 블랙메일링을 막는 효율적인 방법)

  • 박혜영;한동국;이동훈;이상진;임종인
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.6
    • /
    • pp.125-135
    • /
    • 2002
  • The electronic payment system based on blind signature is susceptible to the blackmailing attack as opposed to keep the lifestyle of users private. In this paper. we suggest an efficient electronic cash system using a blind XTR-DSA scheme, which improves the method of defeating blackmailing in online electronic cash systems of [6,9]. In case of blackmailing, to issue the marked coins we use the blind XTR-DSA scheme at withdrawal. In [6,9], to cheat the blackmailer who takes the marked coins the decryption key of a user had to be transferred to the Bank. But in our proposed method the delivery of the decryption key is not required. Also, in the most serious attack of blackmailing. kidnapping, we can defeat blackmailing with a relatively high probability of 13/18 compared with 1/2 in [9] and 2/3 in [6]. If an optimal extension field of XTR suggested in [7] is used, then we can implement our system more efficiently.

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

The Technologic Consideration of Using for DSA (DSA에 대한 기술적 고찰)

  • Cho, Young-Ki
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The paper is on the record of radiography the patients with SIEMENS ANGIOSTAR/POLYTRON S PLUS angiosystem with DSA system in the Chonbuk National University Hospital from October 1993 to June 1994. The results are as follow : 1. Among the total No, 836 case of utilization, angiography are 316(37.8 %), interventional radiography are 256(34.2 %), and dacryocystography and sialography are 168(20/1 %). Therefore non-angiogrlphy procedure are incerasing. 2. The aomunt of contrast material used are half as much as conventional angiovascular system. 3. The amount of film consumed are $10{\sim}15%$ of that of conventional angio vascular system and reduction of procedure time are $40{\sim}50%$. 4. Admitting that dignostic utility is in the utilization by examination region, there should be technological study which deal with fine vessel and motion artifact problem.

  • PDF

Effect of Thermally Grown TiO2 Interlayer on Chlorine Evolution Efficiency and Durability of Ti/RuO2-PdO-TiO2 Electrodes (열산화법으로 생성된 TiO2 중간보호층이 Ti/RuO2-PdO-TiO2전극의 염소발생 효율 및 내구성에 미치는 영향)

  • Park, Da Jung;Choi, Sung Mook;Lee, Kyu Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.4
    • /
    • pp.207-213
    • /
    • 2018
  • Not only efficiency of chlorine evolution reaction (CER) but also durability namely service life is very important property in dimensional stable anode for Ballast Water Management System (BWMS) for marine ships. Many researchers have been focused on improving efficiency of CER by controlling composition, phase and surface area for a long time, but the efforts to increase durability was relatively small. In this study, we have investigated the effect of $TiO_2$ protective interlayers on efficiency and durability of DSA electrodes. $TiO_2$ protective interlayers were prepared by thermal oxidation at 500, 600 and $700^{\circ}C$ on Ti substrate. And then the DSA electrodes consisting of $Ti/RuO_2-PdO-TiO_2$ were prepared by thermal decomposition method on $TiO_2$ interlayers. The efficiencies of CER of DSA electrodes without $TiO_2$ interlayer and with $TiO_2$ interlayer grown at 500, 600 and $700^{\circ}C$ were 94.19, 94.45, 84.60 and 76.75% respectively. On the otherhand, durabilities were 30, 55, 90 and 65 hours respectively. In terms of industrial aspect, the performance of DSA is considered high efficiency and durability which can correspond to total production of chlorine. If we considered the performance index of DSA as the product of efficiency and durability, performance indices could be recalculated as 28.26, 50.85, 76.14 and 49.89 respectively. As the thermal oxidation temperature increasing, life time were increased remarkerbly, while efficiency of CER was decreased slightly. As a result, DSA electrode with $TiO_2$ interlayer grown at $600^{\circ}C$ has shown about 2.7 times performace of original DSA electrode without $TiO_2$ interlayer.