• 제목/요약/키워드: DROP

검색결과 6,826건 처리시간 0.031초

노년남성의 체형분류에 관한 연구 (A Study on the Classification of Elderly Male's Body Type)

  • 김수현;이정란
    • 한국의류학회지
    • /
    • 제27권6호
    • /
    • pp.624-634
    • /
    • 2003
  • The purpose of this study was to classify body types of elderly male aged between 60 and 80. 40 direct items and 22 indexes were measured. The result were as follows. First. through the factor analysis of indexes, 8 factors were extracted upon factor scores, 4 clusters represented characteristics of elderly male's body type. Type 1 indicates flat and bend-forward type. Type 2 indicates fat and bend-forward type. Type 3 indicates lean-back type and is a little bit fat and the waist is round. Type 4 indicates a straight type in which the chest and the hip are developed. Second, drop was needed to discriminate elderly male's body type. 3 types of drop were extracted. The body type with big drop is Y type in which the drop distance is between 14 and 22cm. The body type with standard drop is A type in which the drop distance is between 6 and 14cm. The body type with small drop is B type in which the drop distance is between -4 and 6cm. Third, when the types of appearance rate were combined, 7 body types of elderly male showed high appearance rate; A1, B1, A2, B2, A3, A4, B4. According to the above result, flat and bended-forward type with drop A was dominant body type of elderly male.

일체형원자로 제어봉구동장치의 낙하 및 완충특성 (Drop and Damping Characteristics of the CEDM for the Integral Reactor)

  • 최명환;김지호;허형;유제용
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.658-664
    • /
    • 2010
  • A control element drive mechanism(CEDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod containing a neutron absorbing material within a reactor core to control the reactivity of the core. The ball-screw type CEDM for the integral reactor has a spring-damper system to reduce the impact force due to the scram of the CEDM. This paper describes the experimental results to obtain the drop and damping characteristics of the CEDM. The drop tests are performed by using a drop test rig and a facility. A drop time and a displacement after an impact are measured using a LVDT. The influences of the rod weight, the drop height and the flow area of hydraulic damper on the drop and damping behavior are also estimated on the basis of test results. The drop time of the control element is within 4.5s to meet the design requirement, and the maximum displacement is measured as 15.6 mm. It is also found that the damping system using a spring-hydraulic damper plays a good damper role in the CEDM.

Deformation and Break-up of a Drop in Contraction Flow

  • Davidson Malcolm R.;Cooper-White Justin
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.17-18
    • /
    • 2003
  • Drop deformation in a cylindrical contraction geometry, characterized here by the formation of a thread of drop fluid in the contraction, is predicted using a Volume-of-Fluid numerical technique. The predicted drop shape is found to closely follow the observed deformation. A capillary instability in the developing drop thread in the contraction was predicted, in agreement with experimental observation.

  • PDF

휴대용 단말기의 낙하충격해석 및 실험적 검증 (Drop/Impact Simulation and Experimental Verification of Mobile Phone)

  • 김진곤;이준영;이신영
    • 대한기계학회논문집A
    • /
    • 제25권4호
    • /
    • pp.695-702
    • /
    • 2001
  • In this paper, the drop/impact simulation for a mobile phone has been carried out with the explicit code LS-DYNA and its validation has been experimentally verified. The small size of this kind of electronics products makes it time-consuming, and difficult to conduct drop tests to detect the failure mechanism and identify their drop behaviors. Strict drop/impact performance criteria of such hand held electronic products as mobile phones play an important role in their design because these products must withstand both normal and unexpected shock. Usually, the product durability on drop impact depends on designers experience. The present reliable methodology of drop/impact simulation provides an efficient and powerful vehicle to improve the design quality and reduce the design period.

Challenging a Single-Factor Analysis of Case Drop in Korean

  • Chung, Eun Seon
    • 한국언어정보학회지:언어와정보
    • /
    • 제19권1호
    • /
    • pp.1-18
    • /
    • 2015
  • Korean marks case for subjects and objects, but it is well known that case-markers can be dropped in certain contexts. Kwon and Zribi-Hertz (2008) establishes the phenomenon of Korean case drop on a single factor of f(ocus)-structure visibility and claims that both subject and object case drop can fall under a single linguistic generalization of information structure. However, the supporting data is not empirically substantiated and the tenability of the f-structure analysis is still under question. In this paper, an experiment was conducted to show that the specific claims of Kwon and Zribi-Hertz's analysis that places exclusive importance on information structure cannot be adequately supported by empirical evidence. In addition, the present study examines H. Lee's (2006a, 2006c) multi-factor analysis of object case drop and investigates whether this approach can subsume both subject and object case drop under a unified analysis. The present findings indicate that the multi-factor analysis that involves the interaction of independent factors (Focus, Animacy, and Definiteness) is also compatible with subject case drop, and that judgments on case drop are not categorical but form gradient statistical preferences.

  • PDF

펄스 GMA용접에서 용융 액적의 동특성 및 펄스 조건에 관한 해석 (Analysis of Dynamic Characteristics of Molten Drop and Pulse Condition in Pulsed-GMAW)

  • 최상균;강세령;이상룡
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.491-497
    • /
    • 2002
  • Dynamic behavior of the molten drop during the peak period in the pulsed-GMAW is simulated in this work using the VOF(volume of the fluid) algerian. The dynamic characteristics of molten drop such as minimum radius, average velocity and displacement of mass center were computed as well as the internal pressure and velocity. The minimum and maximum peak durations for detaching a drop were calculated.. The result of Analysis reveals that peak current and volume of pendant drop are important factors which affecting drop detachment. A simplified model of constant acceleration is proposed to describe the behavior of molten drop during peak current, and its results agree with the experimental results.

Pressure Drop in Two-Phase Flow Boiling of R134a, R123 and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.70-78
    • /
    • 2004
  • An experimental study on the pressure drop during flow boiling for pure refrigerants Rl34a and R123, and their mixture was carried out in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6㎫ and in the ranges of heat flux 5-50㎾/$m^2$, vapor quality 0-100 percent and mass velocity of 150-600 kg/$m^2$s. Generally, the two-phase frictional multiplier is used to predict the frictional pressure drop during the two-phase flow boiling. The obtained results have been compared to the existing various correlations for the two-phase multiplier. Also, the frictional pressure drop was compared to a few available correlations; The Lockhart-Martinelli correlation considerally overpredicted the frictional pressure drop data for mixture as well as pure components in the entire mass velocity ranges employed in the present study, while the Chisholm correlation underpredicted the present data. The Friedel correlation was found to satisfactorily correlate the frictional pressure drop data except for a low quality region.

Evaluation of Condensation Pressure Drop Correlations for Microfin Tubes

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.169-174
    • /
    • 2007
  • The characteristics of nine existing condensation frictional pressure drop correlations for microfin tubes were evaluated with geometries, vapor quality, mass flux, and refrigerants. The $M\ddot{u}ller-Steinhagen$ and Heck [17] smooth tube frictional pressure drop correlation was utilized to evaluate the pressure drop penalty factor (PF). Except the Nozu et al. [2], the Kedzierski and Goncalves [3], the Choi et al. [10], and the Cavallini et al. [7], other pressure drop correlations did not consider the effect of tube geometry. The prediction values for R407C by pressure drop correlations show discrepancy with previous researcher's experimental trend. Additional efforts on the development of reliable condensation pressure drop correlation for microfin tubes are still required with the systematic investigation of various effects like geometries and working conditions.

Drop Performance Test of Conceptually Designed Control Rod Assembly for Prototype Generation IV Sodium-Cooled Fast Reactor

  • Lee, Young-Kyu;Lee, Jae-Han;Kim, Hoe-Woong;Kim, Sung-Kyun;Kim, Jong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.855-864
    • /
    • 2017
  • The control rod assembly controls reactor power by adjusting its position during normal operation and shuts down chain reactions by its free drop under scram conditions. Therefore, the drop performance of the control rod assembly is important for the safety of a nuclear reactor. In this study, the drop performance of the conceptually designed control rod assembly for the prototype generation IV sodium-cooled fast reactor that is being developed at the Korea Atomic Energy Research Institute as a next-generation nuclear reactor was experimentally investigated. For the performance test, the test facility and test procedure were established first, and several free drop performance tests of the control rod assembly under different flow rate conditions were then carried out. Moreover, performance tests under several types and magnitudes of seismic loading conditions were also conducted to investigate the effects of seismic loading on the drop performance of the control rod assembly. The drop time of the conceptually designed control rod assembly for 0% of the tentatively designed flow rate was measured to be 1.527 seconds, and this agrees well with the analytically calculated drop time. It was also observed that the effect of seismic loading on the drop time was not significant.

A Multiobjective Model for Locating Drop-off Boxes for Collecting Used Products

  • Tanaka, Ken-Ichi;Kobayashi, Hirokazu;Yura, Kenji
    • Industrial Engineering and Management Systems
    • /
    • 제12권4호
    • /
    • pp.351-358
    • /
    • 2013
  • This paper proposes a multiobjective model describing the trade-offs involved in selecting the locations of drop-off boxes for collecting used products and transporting these products to designated locations. We assume the following reverse flow of used products. Owners of used products (cellular phones, digital cameras, ink cartridges, etc.) take them to the nearest drop-off box when the distance is reasonably short. We also assume that owners living closer to drop-off boxes dispose of more used products than do owners living farther from drop-off boxes. Different types of used products are collected, with each type requiring its own drop-off box. A transportation destination for each product is specified. Three objectives are considered: maximizing the volume of used products collected at drop-off boxes; minimizing the cost of transporting collected products to designated locations; and minimizing the cost of allocating space for drop-off boxes. We formulate the above model as a multiobjective integer programming problem and generate the corresponding set of Pareto optimal solutions. We apply the model to an area using population data for Chofu City, Tokyo, Japan, and analyze the trade-offs between the objectives.