• 제목/요약/키워드: DROP

검색결과 6,826건 처리시간 0.029초

수평 다채널에서의 압력강하에 관한 새로운 상관식 (A New Correlation on Pressure Drop in Horizontal Multi Channels)

  • 최용석;임태우;유삼상;김환성
    • 수산해양교육연구
    • /
    • 제28권5호
    • /
    • pp.1273-1279
    • /
    • 2016
  • Flow boiling pressure drop in multi channels was experimently investigated. The multi channel has a width and depth of 0.45 and 0.2mm respectively, and comprises 15 parallel channels. The measured total pressure drop is expressed by the sum of the frictional pressure drop and acceleration pressure drop. In order to predict the total pressure drop, it is required to obtain the correct frictional pressure drop. The existing correlations to predict the frictional pressure were compared with measured frictional pressure drop. The new correlation was developed in the form of the Chisholm correlation. It was related to Chisholm Constant B as a function of Martinelli parameter. The new correlation predicted the experimental data within a mean absolute error of 5.5%.

Gate Length Optimization for Minimum Forward Voltage Drop of IGBTs

  • Moon Jin-Woo;Park Dong-Wook;Choi Yearn-Ik;Chung Sang-Koo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.246-250
    • /
    • 2005
  • The forward voltage drop of IGBT is studied numerically and analytically as a function of gate length. An analytical expression is presented for the first time for the surface potential variation along the channel layer under the gate of IGBT. The surface potential drop and the carrier density near the surface allow calculation of the forward voltage drop of IGBT analytically as a function of the gate length. The voltage-drop in the drift region near the gate decreases exponentially, whereas that on the surface increases linearly with increasing the gate length, the sum of which exhibits an optimum gate length, resulting in a minimum forward voltage drop. Based on the surface potential drop, a remodelling of the forward voltage drop of IGBT is also proposed.

냉연판의 엣지드롭 해석 및 제어용 수식모델 개발 (Analysis of edge drop and development of numerical formula for edge drop control of cold rolled sheet)

  • 송길호;박해두;진철제;신성갑
    • 대한기계학회논문집A
    • /
    • 제22권4호
    • /
    • pp.723-730
    • /
    • 1998
  • With the introduction of edge drop control system in Tandem Cold Rolling Mill, it is necessary to develop te numerical expression for the set-up and edge drop automatic control of cold rolled sheet. As a first step we developed a simulation program which predicts profile and the amounts of edge drop at the delivery side of each stand by using roll deformation anlysis with the slit roll model. And by using the program the effect of various rolling conditions on edge drop was investigated. As a result the relations were obtained between the amounts of edge drop and rolling conditions. Based on above relations, the numerical expression was developed for the set-up and automatic control of edge drop by multi-regression of simulation results for the variation of edge drop amount with each rolling condition.

TAB 모텔과 수정된 액적 항력 모텔을 이용한 공기 보초 분무에서의 액적 분열에 대한 수치적 연구 (Numerical Study an Drop Breakup in Air-Assisted Spray Using the TAB Model with a Modified Drop Drag Model)

  • 고권현;유홍선;이성혁;홍기배
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.87-95
    • /
    • 2002
  • The aim of this article is to perform the numerical simulation far drop drag and breakup processes in air-assisted sprays using the Taylor analogy breakup (TAB) model with a modified drop drag model, in which a random method is newly used to consider the variation of the drop's frontal area. The predicted results for drop trajectory and Salter mean diameter (SMD) were compared with experimental data and the simulation results using the earlier published models such as TAH model, surface wave instability (Wave) model, and Wave model with original drop drag model. In addition, the effects of the breakup model constant, Ck, on prediction of spray behaviors were discussed. The results shows that the TAB model with the modified drop drag model is in better agreement with experimental data than the other models, indicating the present model is acceptable for predicting the drop breakup process in air-assisted sprays. At higher Weber numbers, the smaller Ck shows the best fitting to experimental data. It should be noted that more elaborated studies is required in order to determine the breakup model constant in the suggested model in the study.

점안 지도가 항녹내장 안약의 처방 순응도에 미치는 영향 (Effect of Eye Drop Education on Adherence to Glaucoma Medication)

  • 박경지;송현주;손의동
    • 약학회지
    • /
    • 제57권2호
    • /
    • pp.139-149
    • /
    • 2013
  • Glaucoma is a potentially blinding chronic disease requiring life-long commitment to medical therapy. Failure to adhere to anti-glaucoma treatment may lead to disease progression and visual loss. This study surveyed the adherence to glaucoma eye drop and eye drop instillation technique of glaucoma patients and analyzed the improvement of the adherence and installation technique after patient education for eye drop instillation instructions. Collected responses were statistically analyzed using Kruskal-Wallis test, Mann-Whitney test, Chi-square test, Fisher's exact test, Spearman's correlation coefficient, or one sample proportion test. The survey after patient education for proper eye drop instillation revealed that, even if the patients experienced the adverse effect of their eyes getting dry, they used the eye drop more regularly. They were better at instillation techniques like putting the eye drop inside the eye, and also avoiding applying too much medication or touching their eye with the eye drop bottle. Also, when the patients were divided into groups based on etiologic division, there was difference among groups regarding which category they answered has improved. The result showed improvement in adherence to glaucoma eye drop and eye drop instillation technique after patient education, implicating that patient education is an important aspect of eye care for glaucoma patient and helps them participate in the proper management.

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

항공우주구조물 낙하충격시험기 개발 및 응용 (Development and Application of Drop Impact Tester for Aerospace Structures)

  • 신예솔;김혜진;이주호
    • 항공우주시스템공학회지
    • /
    • 제18권3호
    • /
    • pp.56-64
    • /
    • 2024
  • 본 연구에서는 항공우주구조물의 낙하 충격 특성 및 기초 시험, 학술적 연구를 종합적으로 수행하기 위하여 낙하충격시험기를 개발하였다. 낙하충격시험기는 항공기가 지면과의 충돌 시 발생하는 동적인 응력과 변형에 대한 정확한 평가를 가능하게 하며, 안전성 및 기구 강도와 같은 중요한 설계 요소들을 확인할 수 있도록 한다. 낙하충격시험기는 전자석을 이용하여 시험체를 부착 및 낙하하며, 크레인을 이용하여 시험체 낙하 높이 조절이 가능하도록 구성하였다. 또한, 수직 낙하를 위한 낙하보조장치를 제작하였다. 시험을 위한 낙하 시험체의 수치해석을 수행하고 낙하충격시험기를 활용하여 기초 시험을 수행하였다. 해석 및 시험 결과를 통해 착륙장치 낙하 상황에서의 구조적 형상을 분석하고 각 부분의 거동을 종합적으로 평가하였다.

Comparison of the thickness of the gastrocnemius through ultrasonography during heel-drop exercise performance

  • Gal, Dan-Bee;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권2호
    • /
    • pp.89-94
    • /
    • 2016
  • Objective: This study was aimed to compare the thickness and pennation angle of gastrocnemius through ultrasonography during the heel-drop exercise on ankle dorsiflexion angle. Design: Cross-sectional study. Methods: Nineteen normal adults in their 20s had voluntarily participated in this study. All subjects performed the ankle heel-drop exercise with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$: heel-drop exercise with ankle dorsiflexed to $0^{\circ}$ was executed on floor-level, heel-drop exercise with ankle dorsiflexed to $10^{\circ}$ on a wooden-block of 2.3 cm in height, and heel-drop exercise with ankle dorsiflexed to $20^{\circ}$ on a wooden-block of 5.5 cm in height. In each regimen, the subjects completed a session of 100 heel-drop exercises (10 repetitions${\times}$10 sets; with 30 seconds rest following each set; with 24 hours rest following each exercise). Before and immediately after each heel-drop exercise, the thickness and pennation angle of gastrocnemius were measured using an ultrasonography. Results: After the performance of the heel drop exercises with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$, the thickness of the gastrocnemius was significantly higher than pre-exercise (p<0.05), and furthermore heel-drop exercise with ankle dorsiflexed to $10^{\circ}$ was significantly higher than exercise with the ankle dorsiflexed to $0^{\circ}$ (p<0.05). However, as for the pennation angle of the gastrocnemius, there were no significant changes after each heel-drop exercise. Conclusions: This finding suggest that the heel-drop exercise with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$ is effective on the strengthening of the gastrocnemius. Furthermore, the heel-drop exercise with the ankle dorsiflexed to $10^{\circ}$ is more effective than with the ankle dorsiflexed to $0^{\circ}$.

20대 여성의 드롭에 따른 체형 연구 (The Study of Somatotype According to the Drop of Women in Their 20's)

  • 박주희;홍정민;윤진경
    • 한국의류산업학회지
    • /
    • 제7권5호
    • /
    • pp.494-500
    • /
    • 2005
  • This study classifies somatotype from exact measurements according to the women somatotype with different drop value and isfunctional and has high body fitness. This study was preceded in the following process. Took 147 women in their 20's measurement directly and grasped the general body characteristic, and classified somatotype according to distribution of drop. Drop value is classified into Drop I, Drop II, and Drop III. Drop I is the difference value between bust line and waist line measurement. Drop II is the difference value between hip line and waist line measurement. Drop III is the difference value between hip line and bust line measurement. Suggested distribution of somatotype based on drop istribution. Classified somatotype into 4 types according to the mixture of combination of Drop I, II, and III. Comprehended the characteristics of somatotype based on basic statistical data. Type 1, M type, displays 40 % distribution that is most high distribution rate among four types and it is normal type which is similar to average value in size in the this study. Type 2, A type, displays 32.4% and it's a lower half of their body developed type with a flat busted and hippy. Type 3, X type, displays 19% and it's a healthy type with tall height, slender waist and curves of bust and hip lines. Type 4, H type, displays 8.6% and it's a biggest type in size which is busty, full hipped and nearly has no curves of body line.

PGSFR 제어봉집합체 낙하성능시험 (Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor)

  • 이영규;김회웅;이재한;구경회;김종범;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.