• Title/Summary/Keyword: DP system

Search Result 258, Processing Time 0.029 seconds

IMPLEMENTATION OFWHOLE SHAPE MEASUREMENT SYSTEM USING A CYLINDRICAL MIRROR

  • Uranishi, Yuki;Manabe, Yoshitsugu;Sasaki, Hiroshi;Chihara, Kunihiro
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.601-605
    • /
    • 2009
  • We have proposed a measurement system for measuring a whole shape of an object easily. The proposed system consists of a camera and a cylinder whose inside is coated by a mirror layer. A target object is placed inside the cylinder and an image is captured by the camera from right above. The captured image includes sets of points that are observed from multiple viewpoints: one is observed directly, and others are observed via the mirror. Therefore, the whole shape of the object can be measured using stereo vision in a single shot. This paper shows that a prototype of the proposed system was implemented and an actual object was measured using the prototype. A method based on a pattern matching which uses a value of SSD (Sum of Squared Difference), and a method based on DP (Dynamic Programming) are employed to identify a set of corresponding points in warped captured images.

  • PDF

Potable Water Treatment Study using the Double Stage Fiber Filter for the Pre-treatment of the Reverse Osmosis Membrane (역삼투막 전처리로서의 2단 섬유상 여과기를 이용한 정수처리 연구)

  • Bae, Si-Youl;Jang, Hyung-Wook;Yun, Chang-Han
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • This study was to evaluate the performance of the Double stage Pore controllable fiber (DP) filter system as the pre-treatment of the RO membrane. The evaluation for the pre-treatment filter was performed through the indirect method, SDI (Silt Density Index) measurement of the filtrate. This study was done during Jan. 3 of 2009 to Dec. 3 of 2009 at OO Water Treatment Plant that was suppling industrial water to plants, and the raw water was contaminated lake water and it was fed to the system after clarification with coagulation. The average turbidity of the feed water and that of the filtrate was 0.79 NTU (0.28~4.01 NTU), and 0.16 NTU (0.04~0.50) respectively. And so the average turbidity removal efficiency was 77%. The filtrate flow rate and the backwash water flow rate was about 230 $m^3$/day and about 8.7 $m^3$/day respectively, and so the backwash rate was 3.8%. The data for some samples were obtained after a few days storage, and it caused the higher turbidity and SDI15 as the storage time was increased. But average SDI value of the filtrate was 3.6 (2.26~5.00) which was lower than minimum value required by the RO membrane manufacturer as the RO feed water to guarantee the life time of the RO membrane. So, the DP filter system was enough for the application as the pre-treatment of the RO membrane.

Preparation of Highly Porous Poly(d,l-lactic-co-glycolic acid) (PLGA) Microspheres (다공성 PLGA 마이크로입자 제조법의 최적화 연구)

  • Park, Hong-Il;Kim, Huyn-Uk;Lee, Eun-Seong;Lee, Kang-Choon;Youn, Yu-Seok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.3
    • /
    • pp.167-171
    • /
    • 2009
  • Poly(lactic-co-glycolic acid) (PLGA) microspheres have been a useful tool as a controlled drug delivery system for peptides and proteins. Recently, porous microspheres have gained great attention as inhalation drug delivery system due to their low aerodynamic densities. Here, we report highly porous PLGA microspheres, which were prepared by using a single o/w emulsification/solvent evaporation method. Two types of porogen, i.e., (i) extractable Pluronic F127 and (ii) gas foaming salt of ammonium bicarbonate, were used to induce pores on the surface of PLGA microspheres. The respective preparation conditions on dp/cp ratio and porogen concentration were determined by the previous preliminary experiments, and other preparation factors were further optimized on the basis of PLGA Mw and porogen type. The morphological features examined by scanning electron microscope (SEM) show these porous microspheres have highly porous surface structure with a diameter range of 20${\sim}$30 ${\mu}$m. These highly porous PLGA microspheres, which have much lower density, would be a practical aerosol system for pulmonary drug delivery.

Optimal Control of Multireservoirs Using Discrete Laguerre Polynomials (Laguerre Polynomial을 이용한 저수지군의 최적제어)

  • Lee, Jae Hyoung;Kim, Min Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.4
    • /
    • pp.91-102
    • /
    • 1991
  • Traditionally, a dynamic programming(DP) technique has been used to the multireservoir control system. The algorithm has inherent problem to increase computational requirements exponentially due to discretization of variables and expanding the dimension of the system. To solve this problem, this paper describes transforming the optimal control system into a quadratic programming(QP), using Laguerre polynomials(LP) and its properties. The objective function of the proposed QP is independent of time variable. The solution of the QP is obtained by nonlinear programming(NLP) using augmented Lagrangian multiplier method. The numerical experiment shows that the water level of reservoirs is higher than Lee's and the evaluated benefit value is about the same as other researcher's.

  • PDF

Empirical Initial Scantling Equations on Optimal Structural Design of Submarine Pressure Hull

  • Oh, Dohan;Koo, Bonguk
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The submarine is an underwater weapon system which covertly attacks the enemy. Pressure hull of a submarine is a main system which has to have a capacity which can improve the survivability (e.g., protection of crews) from the high pressure and air pollution by a leakage of water, a fire caused by outside shock, explosion, and/or operational errors. In addition, pressure hull should keep the functional performance under the harsh environment. In this study, optimal design of submarine pressure hull is dealt with 7 case studies done by analytic method and then each result's adequacy is verified by numerical method such as Finite Element Analysis (FEA). For the structural analysis by FEM, material non-linearity and geometric non-linearity are considered. After FEA, the results by analytic method and numerical method are compared. Weight optimized pressure hull initial scantling methods are suggested such as a ratio with shell thickness, flange width, web height and/or relations with radius, yield strength and design pressure (DP). The suggested initial scantling formulae can reduce the pressure hull weight from 6% and 19%.

An Implementation of Speech Recognition System for Car's Control (자동차 제어용 음성 인식시스템 구현)

  • 이광석;김현덕
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.3
    • /
    • pp.451-458
    • /
    • 2001
  • In this paper, we propose speech control system for a various control device in the car with real time control speech. A real time speech control system is detected start-end points from speech data processing by A/D conversion, and recognize by one pass dynamic programming method. The results displays a monitor, and transports control data to control interfaces. The HMM model is modeled by a continuous control speech consists of control speech and digit speech for controlling of a various control device in the car The recognition rates is an average 97.3% in case of word & control speech, and is an average 96.3% in case of digit speech.

  • PDF

Universal Quantification by Children (보편 양화사 (Universal Quantifier)에 대한 아동들의 해석 양상)

  • 강혜경
    • Language and Information
    • /
    • v.5 no.2
    • /
    • pp.39-55
    • /
    • 2001
  • This paper investigates the idiosyncratic understanding of universal quantifiers such as every, each or all by young children at the ages of 4 to 7, and argues that the phenomenon is explicable in terms of the maturation of both the cognitive system and the linguistic system. Evidence for this dual explanation comes from the fact that the visual input, a picture, plays a key role in determining the children's conceptual representation, suggesting the need for the central integration of visual and linguistic elements; and from the fact that a quantifier in the linguistic input has an intrinsic property, i.e. a <+focus> feature. I have tried to explain the nature of the cognitive factors in terms of the function of the central system, suggesting a modified form of Smith & Tsimpli's (1995) yersion of Fodor's (1983) modularity hypothesis. The categorial status of the quantifier in the children's interpretation is considered, focusing on the movement of that quantifier out of its own extended projection to FP. It is claimed that children initially treat quantifiers as modifiers, rather than functional heads, and that the phenomenon of quantifier spreading by children can be attributed to delay in the development of the relevant functional category, i.e., DP (or QP), in language acquisition.

  • PDF

The Development of an Expert System for Supporting the Diagnosis of Diffuse Interstitial Lung Diseases by High Resolution Computed Tomography$^1$

  • Heon Han;Chung, Sung-Hoon;Chae, Young-Moon
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2001.01a
    • /
    • pp.378-382
    • /
    • 2001
  • The purpose of this study was to develop an expert system supporting the diagnosis of diffuse interstitial lung disease by high resolution computed tomography. CLIPS(C language integrated production system) with rule-based reasoning was used to develop the system. Development of expert system had three stages knowledge acquisition, knowledge representation, and reasoning. Knowledge was obtained and integrated, from tables and figure legends of a representative textbook in the domain of this expert system, High-Resolution CT of the Lung, by Webb WR, Mueller NL, and Naidich DP. The acquired knowledge was analyzed to form a knowledge base. Overlapping knowledge was eliminated, similar pieces of knowledge were combined and professional terms were defined. The most important knowledge of findings was then selected for each disease. After groupings of combined findings were made, disease groups were analyzed sequentially to determine final diagnoses. The system was based upon the input of 69 diseases, 185 findings, 73 conditions, 387 status, and 62 rules. The system was set up to determine the diagnoses of diseases from the combination of findings using forward reasoning. In an empirical trial, the system was applied to support the diagnosis of 40 cases of diffuse interstitial lung diseases. The performance of two doctors with support of the system was compared to that of another two doctors without support of the system. The two doctors with the support of the system made more accurate diagnoses than the doctors without the support of the system. The system is believed to be useful for the diagnosis of rare diseases and for cases with many possible differential diagnoses. In conclusion, an expert system supporting the high resolution computed tomographic diagnosis of diffuse interstitial lung disease was developed and the system is thought to be useful for medical practice.

  • PDF

Development of Optimal Operation Algorithm about CES Power Plant (CES 발전소의 최적운용 알고리즘 개발)

  • Kim, Yong-Ha;Park, Hwa-Yong;Kim, Eui-Gyeong;Woo, Sung-Min;Lee, Won-Ku
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • Recently due to the increasing of the importance on the green energy is getting higher by implementing EERS(Energy Efficiency Resource Standards) and NA(Negotiated Agreement) such as lacks of natural resources and The United Nations Framework Convention on Climate Change. And the most practical solution is CHP(Combined Heat and Power) which performs the best energy efficiency. This paper developed optimal operation mechanism of CES(Community Energy System) for enhancement of energy efficiency using CHP(Combined Heat and Power), PLB(Peak Load Boiler) and ACC(ACCumulator) capacities. This method optimally operated these capacities calculated the maximum profits by Dynamic Programing. Through the case studies, it is verified that the proposed algorithm of can evaluate availability.

A study on the interactive speech recognition mobile robot (대화형 음성인식 이동로봇에 관한 연구)

  • 이재영;윤석현;홍광석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.97-105
    • /
    • 1996
  • This paper is a study on the implementation of speech recognition mobile robot to which the interactive speech recognition techniques is applied. The speech command uttered the sentential connected word and is asserted through the wireless mic system. This speech signal transferred LPC-cepstrum and shorttime energy which are computed from the received signal on the DSP board to notebook PC. In notebook PC, DP matching technique is used for recognizer and the recognition results are transferred to the motor control unit which output pulse signals corresponding to the recognized command and drive the stepping motor. Grammar network applied to reduce the recognition speed of the recogniger, so that real time recognition is realized. The misrecognized command is revised by interface revision through the conversation with mobile robot. Therefore, user can move the mobile robot to the direction which user wants.

  • PDF