• Title/Summary/Keyword: DO control

Search Result 7,242, Processing Time 0.038 seconds

Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter (발효기 하드웨어 변환을 이용한 용존산소 제어)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF

A study on Location Condition for Erosion Control Dam - Focus on Chungcheong region and Kyeongsangbuk-do - (사방댐 입지조건에 관한 연구 - 충청지역과 경북지역을 중심으로 -)

  • Park, Sae-Jun;Lee, Joon-Woo;Choi, Yeon-Ho;Kim, Myeong-Jun;Kweon, Hyeong-Keun;Jeon, Yong-Jun
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.223-229
    • /
    • 2010
  • This study is to analyze location conditions for erosion control dams to be constructed in Chungcheongnam-do, Daejeon Metropolitan City, Chungcheongbuk-do and Gyeongsangbuk-do in order to establish proper conditions for erosion control dams in the future. 199 sites where erosion control dams are expected to be built in 2010 were chosen and investigated in terms of 12 factors including basin area, basin slope, and landslide risk. The results showed that erosion control dams for Chungcheongnam-do and Daejeon Metropolitan City are mostly impermeable gravity dams mainly composed of concrete. In contrast, Chungcheongbuk-do and Gyeongsangbuk-do are increasing the number of permeable or compound erosion control dams. Basin analysis at planned erosion control dam sites showed that at least 44.5% of the total area has high landslide risk. Gyeongsangbuk-do had the largest basin area for erosion control dam sites at 157.3ha, followed by Chungcheongbuk-do at 64.4ha and Chungcheongnam-do at 54.8ha. Analysis of sand deposits in the Chungcheongnam-do erosion control dam built in 2010 confirmed an average deposit of 971.8m3. The sand deposit capacity and amount of sediment control for erosion control dams have a very low correlation with basin area or flow path slope, and this needs to be addressed in future sand deposit capacity designs.

Fuzzy algorithm of Automatic control for dissolved oxygen in Activated sludge aeration tank (활성슬러지 폐수처리장 폭기조 DO제어를 위한 퍼지 제어 알고리즘 연구)

  • 손건태;김성덕;고주형
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.533-538
    • /
    • 1999
  • Fuzzy algorithm of automatic control for dissolved oxygen(DO) concentration in the aeration tank of an activated sludge process is proposed. Among variables repirometry and air flowrate are selected as significant input factors and the relationship with DO is estimated using a multiple regression model. The DO concentration and the amount of repirometry are fuzzified and the fuzzy rule base are determined. Using the fuzzy algorithm, the change of amount of air flowrate are determined and the change of amount of DO is derived.

  • PDF

Effect and Development of Automatic Control of Dissolved Oxygen on Growth of Phellinus linteus WI-001 (Phellinus linteus WI-001 균사체의 성장에 미치는 용존산소농도의 영향 및 자동 조절방법 개발)

  • 김종래;권호균;전계택;이계관
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.5
    • /
    • pp.285-290
    • /
    • 2000
  • The effects of dissolved oxy-gen(DO) concentration and DO control modes on cell growth in a 4L computer-controlled bioreactor system were investigated using Phellinus linteus WI-001, a producer of protein-polysaccharides having potent anticancer activi-ties. When DO was controlled at about 20%, maximum cell concentration and specific growth rate of the strain were observed to increase 36% and 64%, respectively, as compared to the experiment performed without DO control. By adopting cascade automatic control of DO ar 20% in a mixed automatic control mode using computer-con-trolled program, 19.5g/L of maximum cell concentration was obtained. These results showed that the mixed auto-matic control mode was the effective method for enhancing cell growth of the shear sensitive Phellinus linteus.

  • PDF

Automatic Control Of Dissolved Oxygen In Activated Sludge Aeration Tank

  • Park, Kwang-Soo;Heo, Nam-Hyo;Lee, Hae-Goon;Han, Gee-Baek;Kim, Chang-Won
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • The quality of the effluent from an activated sludge aeration tank can deteriorate when the substrate removal rate decreases due to an abrupt reduction in the DO concentration, which is affected by such operating conditions as the loading rate, temperature, wastewater composition, and so on. In this research, a DO control system that includes a PI (proportional-integral) controller/Hiraoka controller was developed and applied to a pilot-scale activated sludge process, then its acceptability was estimated. The applicability of the respiration rate to DO control was also estimated. The respiration rate indicated a variety of input organic loading rates, which is the main disturbance to the DO concentration in an aeration tank. When the influent concentration incrementally decreased and increased between CODcr 1,000 mg/l and 100 mg/l, the control system with a PI controller exhibited a good llperformance-the average DO concentrations were 2.00$\pm$0.14 mg/l and 1.88$\pm$0.15 mg/l (set value was 2.0 mg/l), respectively, and the settling time was just 10 minites. When the control system was operated for 4 days, the DO concentration was 1.99$\pm$0.18 mg/l and 32.6% of the air flowrate was saved. However, the fluctuations in the respiration rates and air flowrates were severe, which could be harmful to the stability of the biomass and mechanical stability of the blower. A possible approach to solve this problem may be the simultaneous control of the loading rate and DO concentration.

  • PDF

Anti-Sway and Position Control of Overhead Crane Using the LQ Controller (LQ 제어기를 이용한 천정 크레인의 흔들림 억제 및 위치제어)

  • Choi, B.S.;Park, J.W.;Son, J.K.;Kwon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2753-2755
    • /
    • 2003
  • Overhead crane must do to control occurrence of Anti-Sway according to work situation that is used in case move industry spot's heavy freight, and do safe transfer of freight. Transfer process that make use of crane suspends and consist of series action that put down freight to do relevant addition decreasing the speed before objective while move by schedule section equal speed because increasing the speed after lift thing. This need skill degree by experience because there are operator's function and affinity. Also, must control this effectively because can affect big productivity elevation according to effect that get in transfer of safe freight, Therefore, illuminate physical characteristic of crane and algorithm of motor drive department and there is purpose of this research to do so that correct control may be available through over head crane's shaking control and position control designing LQ controller.

  • PDF

Comparison of Proportional, Integral, and P-I Control Systems in Biological Wastewater Treatment Plants (생물학적 하수처리시스템에 적용된 Proportional, Integral 및 P-I 조절 시스템에 대한 비교)

  • Kim, Sungpyo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.410-415
    • /
    • 2005
  • The main purpose of this study is to evaluate the characteristics of three sets of traditional control methods (proportional, integral, and proportional - integral controls) through lab-scale biological reactor experiments. An increase in proportional gain ($K_c$) resulted in reduced dissolved oxygen (DO) offset under proportional control. An increase in integral time ($T_i$) resulted in a slower response in DO concentration with less oscillation, but took longer to get to the set point. P-I control showed more stable and efficient control of DO and airflow rates compared to either proportional control or integral control. Developed P-I control system was successfully applied to lab-scale Sequencing Batch Reactor (SBR) for treating industrial wastewater with high organic strength.

Development and Field Assessment of DO Control System in an Aeration Tank for Automation of Sewage Treatment Plant

  • Jung, In-Chul;Kim, Dae-Yong;Junq, Byung-Gil
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.603-608
    • /
    • 2009
  • Activated sludge sewage treatment processes are difficult to be controlled because of their complex and nonlinear behaviour, however, the control of the dissolved oxygen level in the reactors plays an important role in the operation of the facility. For this reason, this study is designed to present a system which accurately measures DO, MLSS, pH and ORP in the aeration tank to alleviate situations above and provide the automatization of a sewage treatment plant (STP) using new DO control system. The automatic control systems must be guaranteed the accuracy. Therefore, the proposed automatic DO control system in this study could be commercial applications in the aeration tanks by means of operating cost analysis and user-friendly for operation and maintenance. We could get accurate data from the lab tank which has water quality checker because there was no vortex and air bubble during the measurement process. Improvement of confidence in the lab tank enabled effective and automatic operation of sewage treatment plants so that operation costs and manpower could be saved. If this result is put in place in every sewage treatment plant nationwide for practical purposes, it is estimated to cost 18.5 million dollars in installing the lab tank and to save 9.8 million dollars in management cost a year, except for cost saved by automation.