• Title/Summary/Keyword: DNA delivery

Search Result 193, Processing Time 0.033 seconds

Quantification of DNA Delivery Efficiency Labeled with Fluorescent Dye in Digital Electroporation System (디지털 전기천공시스템에서 형광 염료로 표지 된 DNA 전달 효율의 정량화)

  • Bae, Seo Jun;Im, Do Jin
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.450-457
    • /
    • 2020
  • In the previous study, there was a big difference between the tendency of the delivery efficiency of Yo-Pro-1 and the expression efficiency of the CFP gene, but there was a problem that could not provide a clue to this problem. Therefore, this study aimed to present a clue to this problem by quantifying and comparing the delivery efficiency after labeling DNA using a fluorescent dye, which was one of the methods for quantifying biomolecules. As a fluorescent dye for labeling, Yo-Pro-1 was used, and the delivery efficiency of the fluorescent dye Yo-Pro-1 and the labeled DNA was compared. The delivery efficiency of Yo-Pro-1 and labeled DNA according to the voltage condition of the digital electroporation system was maximized at 96 V, and the delivery efficiency tended to decrease as the voltage increased further. In the comparison of the delivery efficiency of Yo-Pro-1 and labeled DNA according to the number of voltage application conditions, the delivery efficiency was maximized at the number of 8 voltage application times for both delivery materials, and the delivery efficiency tended to decrease as the number of voltage application increases further. Through the two results, it was confirmed that the delivery efficiency using Yo-Pro-1 in the digital electroporation system represents the delivery efficiency of the system well. In addition, through the results of this study, the difference between the tendency of the delivery efficiency of Yo-Pro-1 and the expression efficiency of the CFP gene shown in the preceding study was not the result of the difference in the delivery efficiency of the delivery material, but it can be predicted to be due to a problem with the expression process of the genetic material that had been delivered.

F2 Gel Matrix - a Novel Delivery System for Immune and Gene Vaccinations

  • Tuorkey, Muobarak J
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3061-3063
    • /
    • 2016
  • Exploiting the immune system to abolish cancer growth via vaccination is a promising strategy but that is limited by many clinical issues. For DNA vaccines, viral vectors as a delivery system mediate a strong immune response due to their protein structure, which could afflect the cellular uptake of the genetic vector or even induce cytotoxic immune responses against transfected cells. Recently, synthetic DNA delivery systems have been developed and recommended as much easier and simple approaches for DNA delivery compared with viral vectors. These are based on the attraction of the positively charged cationic transfection reagents to negatively charged DNA molecules, which augments the cellular DNA uptake. In fact, there are three major cellular barriers which hinder successful DNA delivery systems: low uptake across the plasma membrane; inadequate release of DNA molecules with limited stability; and lack of nuclear targeting. Recently, a polysaccharide polymer produced by microalgae has been synthesized in a form of polymeric fiber material poly-N-acetyl glucosamine (p-GlcNAc). Due its unique properties, the F2 gel matrix was suggested as an effective delivery system for immune and gene vaccinations.

Apoptosis Induced by Polyethylenimine/DNA Complex in Polymer Mediated Gene Delivery

  • Lee, Min-Hyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.95-98
    • /
    • 2007
  • Polyethylenimine (PEI) has been widely investigated for delivery of DNA into cells. It was previously reported that there were at least two types of cytotoxicity in PEI-mediated gene delivery, immediate and delayed toxicities. PEI-mediated gene delivery protocols use net cationic complexes with an excess of PEI to maintain equilibrium between the complexed and dissociated forms in solution. In this study, toxicity of free PEI or PEI/ DNA complex was investigated. Human embryonic kidney 293 cells were incubated with free PEI or PEI/DNA complex for 4 hrs. Then, the cells were analyzed at 6, 24, 48, and 96 hrs after the incubation. In MTT assay, the viability of the cells incubated with PEI/DNA complex was continuously decreased with time, while that of the cells incubated with free PEI was not. On the contrary, the expression level of the luciferase gene increased gradually along with time. Release of DNAs from the complexes for transcription produces free PEIs in the cells. This process may proceed slowly due to high charge density of PEI and may be related to delayed toxicity. In addition, apoptotic cells were observed only in the cells incubated with the PEI/DNA complex from 24 hrs after the incubation. The results suggest that PEI/DNA complex contributes to the delayed toxicity by inducing apoptosis and that the delayed toxicity may be related to decomplexation of the complexes in the cells.

Polyethylenimine Mediated Gene Delivery with Various Liposomal Formulations (폴리에틸렌이민 및 그들의 리포좀이 중재된 Plasmid DNA의 운반)

  • Han, In Sook;Jun, Mi Sook;Lee, Kab Yong
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.193-198
    • /
    • 1999
  • The transfection efficiency of plasmid DNA was inspected using multi-cationic polymer, 5, 10, 25 and 50KD polyethylenimine (PEI). The optimal neutralization ratio of PEI/DNA complexes by agarose assay was 1.5-2.0 (nmol/nmol) without much difference in molecular weight of PEI.In vitro transfection assay, most of PEI-mediated plasmid delivery was better compared to the naked DNA. Especially, 25KD PEI at optimal condition gave higher transfection rather than the standard assay of DEAE-dextran or Lipofectin. To enhance the cell targeting delivery, the liposome formulations were introduced using phospholipids. As a result, PC/PE liposomes increased 2-2.5 times of the transfection efficiency of PEI single or PC/PE single delivery, but not the case of 25KD PEI. Moreover, the DOTAP/PE-introduced PEI delivery reduced the transfection of DOTAP/PE single delivery. All these results proved that the PEI can be used not only good transfectants and but also good DNA condensing agents in neutral/anionic liposome for cell targeting delivery.

  • PDF

R3V6 Amphiphilic Peptide with High Mobility Group Box 1A Domain as an Efficient Carrier for Gene Delivery

  • Ryu, Jaehwan;Jeon, Pureum;Lee, Minhyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3665-3670
    • /
    • 2013
  • The R3V6 peptide includes a hydrophilic arginine stretch and a hydrophobic valine stretch. In previous studies, the R3V6 peptide was evaluated as a gene carrier and was found to have low cytotoxicity. However, the transfection efficiency of R3V6 was lower than that of poly-L-lysine (PLL) in N2A neuroblastoma cells. In this study, the transfection efficiency of R3V6 was improved in combination with high mobility group box 1A domain (HMGA). HMGA is originated from the nuclear protein and has many positively-charged amino acids. Therefore, HMGA binds to DNA via charge interaction. In addition, HMGA has a nuclear localization signal peptide and may increase the delivery efficiency of DNA into the nucleus. The ternary complex with HMGA, R3V6, and DNA was prepared and evaluated as a gene carrier. First, the HMGA/DNA complex was prepared with a negative surface charge. Then, R3V6 was added to the complex to coat the negative charges of the HMGA/DNA complex, forming the ternary complex of HMGA, R3V6, and DNA. A physical characterization study showed that the ternary complex was more stable than the PLL/DNA complex. The HMGA/R3V6/DNA complex had a higher transfection efficiency than the PLL/DNA, HMGA/DNA, or R3V6/DNA complexes in N2A cells. Furthermore, the HMGA/R3V6/DNA complex was not toxic to cells. Therefore, the HMGA/R3V6/DNA complex may be a useful gene delivery carrier.

Application of in situ gelling mucoadhesive delivery system for plasmid DNA as a macromolecule

  • Park, Jeong-Sook;Oh, Yu-Kyoung;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.236.1-236.1
    • /
    • 2002
  • Mucosal administration of drug or therapeutic gene is emerging as a new route of delivery for systemic and local therapeutics. Previously. in situ gelling system has been applied to chemical drug such as acetaminophen. insulin. prostaglandin E1. and clotrimazole. Plasmid DNA has not been delivered in form of in situ gelling vehicles. To improve the intranasal absorption of plasmid DNA. we designed delivery systems composed of provide of in 냐셔 gelling and mucoadhesive polymers. (omitted)

  • PDF

Studies on Developing Direct Gene Transfer Based on Naked Plasmid DNA for Treating Anemia (Naked Plasmid DNA를 이용한 빈혈 치료용 Direct Gene Transfer 시스템의 개발에 대한 연구)

  • Park Young Seoub;Jung Dong Gun;Choi Cha Yong
    • KSBB Journal
    • /
    • v.19 no.5
    • /
    • pp.341-347
    • /
    • 2004
  • Several gene delivery therapies are being developed for treatment of serum protein deficiency. EPO is one of the most promising therapeutic agent for this treatment which is currently being investigated in depth. This study has the ultimate purpose of improving the gene delivery system for an increase of red blood cell production. A plasmid DNA was constructed smaller than other plasmids for an increase in penetration into animal cells, and two genes were cloned into each vector as a co-delivery system to express erythropoietin, and interluekin-3 or thrombopoietin, which can act on erythroid cell, thus activating hematopoiesis synergically. This co-delivery system has an advantage of decreasing the labour required for industrial production of DNA vaccine. A new plasmid vector, pVAC, in size 2.9 kb, was constructed with the essential parts from PUC 19 and pSectagB, which is much smaller than other plasmid vector and is the size of 2.9 kb. Co-delivery system was constituted by cloning human erythropoietin with each of human interluekin-3 gene or human thrombopoietin gene into both pVAC and pSectagB. As a result, the transfection efficiency of pVAC was higer than that of pSectagB in vitro, and hematocrit level of the mice injected with pVAC is higher than that of other mice. And co-delivery system, made of several plasmid DNAs, was expressed in vitro.

Validation of Heterodimeric TAT-NLS Peptide as a Gene Delivery Enhancer

  • Doh, Kyung-Oh
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.6
    • /
    • pp.788-794
    • /
    • 2015
  • Cationic liposomes have been actively used as gene delivery vehicles despite their unsatisfactory efficiencies because of their relatively low toxicity. In this study, we designed novel heterodimeric peptides as nonviral gene delivery systems from TAT and NLS peptides using cysteine-to-cysteine disulfide bonds between the two. Mixing these heterodimeric peptides with DNA before mixing with lipofectamine resulted in higher transfection efficiencies in MCF-7 breast cancer cells than mixing unmodified TAT, NLS, and a simple mixture of TAT and NLS with DNA, but did not show an adverse effect on cell viability. In gel retardation assays, the DNA binding affinities of heterodimeric peptides were stronger than NLS but weaker than TAT. However, this enhancement was only observed when heterodimeric peptides were premixed with DNA before being mixed with lipofectamine. The described novel transfection-enhancing peptide system produced by the heterodimerization of TAT and NLS peptides followed by simple mixing with DNA, increased the gene transfer efficiency of cationic lipids without enhancing cytotoxicity.

Low Molecular Weight Polyethylenimine-Mitochondrial Leader Peptide Conjugate for DNA Delivery to Mitochondria

  • Choi, Joon-Sig;Choi, Min-Ji;Go, Gyeong-Su;Rhee, Byoung-Doo;KimPak, Young-Mi;Bang, In-Seok;Lee, Min-Hyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1335-1340
    • /
    • 2006
  • It has been found that a number of diseases are associated with mutations in the mitochondrial DNA. Therapeutic gene delivery to mitochondria has been suggested as a clinical option for these diseases. In this study, we developed a gene carrier to mitochondria by the conjugation of mitochondrial leader peptide (LP) to polyethylenimine (PEI). Mitochondrial LP conjugated PEI (PEI-LP) was synthesized with low molecular weight PEI (2,000 Da, PEI2K). Gel retardation assay showed that PEI2K-LP formed complexes at a 1.0/1 weight ratio. In addition, PEI2K-LP protected DNA from the enzymatic degradation for at least 60 min, while naked DNA was completely degraded within 20 min. PEI2K-LP was compared with LP conjugated high molecular weight PEI (25,000 Da, PEI25K) in terms of toxicity and delivery efficiency. MTT assay showed that PEI2K-LP had much lower cytotoxicity than PEI25K-LP to 293 cells. In addition, cell-free DNA delivery assay showed that PEI2K-LP delivered more DNA to mitochondria at a 1.8/1 weight ratio than naked DNA or PEI. This result suggests that PEI2K-LP may be useful for the development of mitochondrial gene therapy system with lower cytotoxicity.

Reduction of Oncogene Expression in Cancer Cells Using siRNA Delivery Systems

  • Kim, Eun-Joong;Kim, Young-Bong;Choi, Han-Gon;Shim, Chang-Koo;Oh, Yu-Kyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.343-348
    • /
    • 2005
  • Recently, siRNA has been emerging as new therapeutic agents for various diseases such as cancers and infectious diseases. However, the evaluation for delivery systems for siRNA has not been fully done. In this study, we designed and delivered siRNA of oncogenic E6 and E7 proteins to several cell lines and tested the delivery efficiencies of various cationic nonviral delivery vectors. Of cationic delivery systems tested in this study, lipid-based Lipofectamine revealed higher delivery efficiency of siRNA to cervical cancer cell line, SiHa, compared to other delivery systems. Notably, the polyethylenimine, which showed the comparable delivery efficiencies in plasmid DNA, did not show significant delivery of siRNA in cervical cancer cells. These results indicate that the mechanisms involved in siRNA delivery might be different from those in plasmid DNA delivery, and that cationic lipid-based delivery vehicles deliver siRNA with higher efficiency to intracellular target sites.