• Title/Summary/Keyword: DLN Combustor

Search Result 13, Processing Time 0.031 seconds

An Experimental Investigation of Combustion Characteristics in a Model Combustor by Reproduction of GE 7FA+e DLN-2.6 Gas Turbine (GE 7FA+e DLN-2.6 연소기를 모사한 모형 가스터빈 연소기의 연소불안정 특성에 대한 실험적 연구)

  • Kim, Min-Ki;Lee, Jang-Su;Park, Seong-Soon;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.231-235
    • /
    • 2009
  • The mainly objectives of this study was a combustion dynamics and instability characteristics in a model dump type combustor which is scale down of GE 7FA+e DLN 2.6 gas turbine combustor with running at Seo-Inchon combined cycle power plant. Model gas turbine injector has 2-stage swirl vane and it's reduced 1/3 size of the original one. The shape of plenum and combustor were designed for similar acoustic characteristics. As the result, this research have been shows the peak frequency of model combustor was changed quarter-wave mode to Helmholtz resonator mode in plenum and longitudinal mode in dump combustor at unstable flame conditions caused by the different of combustor temperature and fuel-air mixture distributions.

  • PDF

GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part II Design of Lab Scale Dump Combustor (GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part II 모형 덤프 연소기 설계)

  • Oh, Jeong-Seog;Kim, Min-Ki;Heo, Pil-Won;Lee, Jang-Soo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.51-59
    • /
    • 2008
  • DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).

Performance Test of 5MW Gas Turbine Engine Combustor (5MW 발전용 가스터빈 엔진 연소기 성능시험)

  • Park, Poo-Min;Kim, Hyung-Mo;Choi, Young-Ho;Yang, Soo-Seok;Chon, Mu-Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.4
    • /
    • pp.37-46
    • /
    • 2008
  • Performance test of 5MW class gasturbine combustor was carried out at combustor test facility of KARI(Korea Aerospace Research Institute). The combustor is dry low NOx type premixed combustor and fuel is natural gas. The characteristics of combustor were measured including emission, pressure pulsation and exit temperature distribution. Optimum operation point of combustor was found by changing parameters like fuel ratio between pilot and main burner. The test result showed that the combustor performance is sufficient to satisfy the gasturbine system requirement.

  • PDF

An Experimental Study of Combustion Characteristics in a Model Gas Turbine Combustor (모형 가스터빈 연소기의 기초 연소특성에 대한 실험적 연구)

  • Lee, Jang-Su;Kim, Min-Ki;Park, Sung-Soon;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.263-266
    • /
    • 2009
  • The mainly objectives of this study was a combustion dynamics and instability characteristics in a model gas turbine dump combustor which is the scale down of GE 7FA+e DLN 2.6 gas turbine combustor. Model gas turbine injector has 2-stage swirl vane and it’s reduced 1/3 size of the original one. The shape of plenum and combustor were designed for similar acoustic characteristics. Inlet air was preheated to $200{\sim}400^{\circ}C$. The flow velocity at mixing nozzle was 30 to 75 m/s and equivalent ratio was 0.4 to 1.2. The combustor length was varied for different acoustic characteristics to $375{\sim}700\;mm$. As the result, this research have been show the combustion instability was observed at lower equivalence ratios ($\Phi$ < $0.5{\sim}0.6$) and higher equivalent ratios ($\Phi$ > $1.1{\sim}1.2$).

  • PDF

GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part Ⅰ Operating Condition Optimization (GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part Ⅰ 운전조건 최적화)

  • Oh, Jeong-Seog;Kim, Min-Ki;Heo, Pil-Won;Lee, Jang-Soo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.43-50
    • /
    • 2008
  • DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).

CFD Simulation of Non-reacting and Reacting Flows for a Gas Turbine Combustor Firing Biogas (바이오 가스터빈 연소기의 비반응장과 반응장의 3차원 유동해석)

  • An, Yun-Ho;Nam, Sam-Sik;Choe, Jin-Hoon;Im, Ji-Hyuk;Kim, Ho-Keun;Chun, Jae-Chul
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.439-444
    • /
    • 2011
  • Doosan Heavy Industries & Construction Co., Ltd. has been recently developing the gas turbine engine using the biogas as fuel. This paper describes the non-reacting and reacting flow analysis of the combustor which is one of the main components in gas turbine engine. Through CFD analysis, investigation has been performed to evaluate the primary factors for aerodynamic design and to predict combustor behaviors during operation with various fuel distribution ratios. The calculation results are compared with rig test data, which reveals that CFD predictions such as pressure loss, air distribution ratio, and recirculation flow are quite reliable. The trend of NO formation was similar with the test, except the low fuel distribution ratio.

  • PDF

Numerical Analysis of Combustion Characteristics during Combustion Mode Change of a Low NOx Utility Gas Turbine (발전용 저 NOx 가스터빈의 연소모드 변환시기의 연소특성 전산해석)

  • Jeong, Jai-Mo;Chung, Jae-Hwa;Park, Jung-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • Three-dimensional numerical investigations are carried out to understand the combustion characteristics inside a DLN(dry low NOx) utility gas turbine combustor during the combustion mode change period by applying transient fuel flow rates in fuel supply system as numerical boundary conditions. The numerical solution domain comprises the complex combustor liner including cooling air holes, three types of fuel nozzles, a swirl vane, and a venturi. Detailed three-dimensional flow and temperature fields before and after combustion mode changeover have been analyzed. The results may be useful for further studies on the unfavorable phenomena, such as flashback or thermal damage of combustor parts when the combustion mode changes.

Quantitative Acetone PLIF Measurement of Fuel Distribution in a Gas Turbine Combustor Burner (아세톤 PLIF를 이용한 가스터빈 연소기 버너 출구 연료분포의 정량적 측정)

  • Jeon, Woo-Jin;Kim, Hyung-Mo;Lee, Kang-Yeop;Yang, Su-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.4
    • /
    • pp.43-52
    • /
    • 2010
  • A non-intrusive measurement, Planar Laser Induced Fluorescence was employed to visualize and measure the fuel distribution of the non-reacting field at the burner exit of gas turbine combustor. Measurement techniques, image processing method and quantification procedure were presented. Also, concentration measurement with gas analyzer was carried out to verify the propriety of PLIF result. The PLIF result coincides well with gas analyzer measurement result. PLIF test result for several other conditions are mentioned as well.

Effects of Combustor Stages on M501J Gas Turbine Combustion (M501J 가스터빈 연소기 단별 연료비율이 연소상태에 미치는 영향 고찰)

  • Yu, Won-Ju;Chung, Jin-Do
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.2
    • /
    • pp.1-8
    • /
    • 2019
  • Most of gas turbine combined cycle power plants are located in urban areas to provide peak load and district heating. However, NOx(nitrogen oxides) of exhaust gas emission from the power plants cause additional fine dust and thus it has negative impact on the urban environment. Although DLN(dry low NOx) and multi-stage combustors have been widely applied to solve this problem, they have another critical problem of damages to combustors and turbine components due to combustion dynamic pressure. In this study, the effect of different fuel ratio on NOx emission and pressure fluctuation was investigated regarding two variable conditions; combustor stages and power output on M501J gas turbine.

Numerical Analysis of Combustion Characteristics during Mode Transfer Period in a Lean Premixed Gas Turbine for Power Generation (발전용 희박예혼합 가스터빈에서 연소모드변환 시기의 연소특성 해석)

  • Chung Jae Hwa;Seo Seok Bin;Kim Jong Jin;Cha Dong Jin;Ahn Dal Hong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.279-282
    • /
    • 2002
  • Recently, gas turbines for power generation adopt multistage DLN(Dry Low NOx) type combustion, where diffusion combustion is applied at low load and, with increase in load, the combustion mode is changed to lean premixed combustion to reduce NOx emissive concentration. However, during the mode changeover from diffusion to premixed flame, unfavorable phenomena, such as flashback, high amplitude combustion oscillations, or thermal damage of combustor parts could frequently occur. In the present study, to apply for the analysis of such unfavorable phenomena, three-dimensional CFD investigations are carried out to compare the detailed flow characteristics and temperature distribution inside the gas turbine combustor before and after combustion mode changeover. The fuel considered here is pure methane gas. A standard $k-{\varepsilon}$ turbulence model with wall function and a P-N type radiation heat transfer model, have been utilized. To analyze the complex geometric effects of combustor parts on combustion characteristics, fuel nozzles, a swirl vane f3r fuel-air mixing, and cooling air holes on the combustor liner wall, are included in this simulation.

  • PDF