• Title/Summary/Keyword: DISTANCE OF MOVEMENT

Search Result 933, Processing Time 0.034 seconds

A Method of Effective Vibration Reduction for Positioning Systems Undergoing Frequent Short-distance Movement (단거리 이동을 반복하는 위치결정장치를 위한 효율적인 진동저감 방법)

  • Hong, Seong-Wook;Bae, Gyu-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.421-428
    • /
    • 2013
  • The current vibration reduction methods for positioning systems lead to either complicated motion or the need for additional hardware when the positioning systems carry out frequent short-distance movements. This paper proposes a simple yet efficient vibration reduction method for positioning systems subjected to frequent short-distance movements. The essence of the proposed method is the trapezoidal or triangular velocity profiles, whose acceleration/deceleration rates are designed to be related to the natural frequency of concern. The combined use of the proposed method and the input shaping method is also proposed for the possible application to multi-mode systems. Experiments are performed to validate the proposed method. The simulation and experiments prove that the proposed method is of great use for residual vibration reduction in positioning systems subjected to frequent short-distance movement.

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

A Study on the Balance of Stroke Patients According to Kneeling Squat Exercise and Standing Squat Exercise Positions (무릎스쿼트 운동과 스쿼트 운동 자세에 따른 뇌졸중 환자의 균형 비교 연구)

  • Go, Gwan-Hyeok;Kim, Byeong-Jo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose : The purpose of this research is to propose a more efficient exercising method by measuring and comparing the movement of center of pressure (COP) while hemiplegic stroke patients perform kneeling squat exercise and squat exercise. Methods : 17 hemiplegic stroke patients were instructed to perform kneeling squat exercises and squat exercises, and the research was designed as a cross-over study. For data collection, a pressure distribution measurement platform (PDM) was used to measure the movement area, length, speed, and distance from the center of the X-axis of center of pressure. The data was then analyzed through a paired t-test. Results : Kneeling squat exercises have been found to have a significantly smaller center of pressure movement area compared to that of squat exercise(p<.001), and the center of pressure movement length of kneeing squat exercise has also been found to be relatively shorter (p<.001). Moreover, kneeling squat exercises have been found to have a significantly slower center of pressure movement speed than squat exercise (p<.001), and kneeing squat exercise center of pressure movement distance from the center of the X-axis has been found to be significantly small (p<.001). Conclusion : Kneeling squat exercises have significantly decreased amounts of center of pressure movement area, distance, and speed compared to squat exercises. Also, the center of pressure movement distance from the center of the X-axis was relatively closer. This result seems to derive from patients performing their motions with wide base surfaces while being refrained from using unstable ankle joints during kneeing squat exercise. Therefore, it can be concluded that kneeing squat exercises show relatively balanced center of pressure movements between the paralyzed and non-paralyzed sides because kneeling squats show smaller shakes in the center of pressure.

Comparison of Postural Sway in the Elderly Males and Females during Quiet Standing and Squat-and-Stand Movement (정적 서기와 쪼그려 앉았다 서기 동작에서 고령자남녀의 자세 동요 비교)

  • Kim, Ji-Won;Kim, Da-Hye;Moon, Ki-Wook;Eam, Gwang-Moon;Nam, Jung-Sook;Kim, Yo-Han;Hong, Jeong-Hwa;Park, Bung-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2131-2137
    • /
    • 2008
  • In this paper, COP (center of pressure) during quiet standing and squat-and-stand movement was analyzed to compare the postural control of young and elderly subjects with special interest in the elderly females who were reported to have higher fall rate than the elderly males. Subjects include the young subjects (10 males: $21.8{\pm}2.6yrs$, 10 females: $20.4{\pm}0.3yrs$) and the elderly subjects (8 males: $75.5{\pm}4yrs$, 8 females: $72.3{\pm}3.5yrs$). Analysis parameters were the mean of the distance between the instantaneous COP and the average COP (COP distance) and the mean of the COP movement velocity (COP velocity) in both AP (anterio-posterior) and ML (media-lateral) directions. During quiet standing, the COP distance in ML direction of elderly females was significantly greater than that of elderly males and the COP velocity of elderly females in both ML and AP direction were significantly greater than those of all the other groups. During squat and stand movement, the COP distance of elderly females was not significantly different with that of the elderly males. However, the COP velocity of elderly females was significantly greater than that of all the other groups. The large lateral weight shift (COP distance) of elderly females during quiet standing may explain their greater fall rate. However, this does not apply to squat-and stand movement. In contrast, COP velocity results show that the elderly females' COP is rapidly trembling compared to that of elderly males during both quiet standing and squat and-stand movement. This results suggest that rapid trembling or postural sway may reflect the reduced postural control ability and the risk of falling.

A COMPUTER ANALYSIS ON THE CONDYLAR PATH IN MANDIBULAR PROTRUSIVE MOVEMENT (하악 전방운동시 과두의 운동궤적에 관한 컴퓨터 분석)

  • Pae, Il-Hwan;Choi, Dae-Gyun;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.39-52
    • /
    • 1991
  • The purpose of this study were to compare the condylar path and the anterior angle of glenoid fossae, and analyze the condylar path, and classify the patterns of condylar path. Thirty-three male and female dental students with normal occlusion and masticatory system ranging in age from 24 to 27, without present symptoms and any history of TM joint disturbance, were selected for this study. Then, sixty-six TM joint were examed. Transcranial radiographs of TM joint and Cephalometric radiographs under mandibular protrusive movement were obtained. They were taken at six positions on protrusive movement. The results obtained were as follows : 1. The sequence of the frequeny of condylar movement patterns were concave curve, "S"shape curve, convex curve, and reverse "S"shape. 2. The horizontal distance of the greatest changed position of condylar angle averaged 2.6mm. 3. The condylar path angle averaged 36.91 degree. 4. The angle of the anterior slope of glenoid fossae averaged 37.28 degree. 5. The distance fo condylar movement averaged 5.98mm and the distance of condylar horizontal movement averaged 4.71mm. 6. The slope of articular eminence was correlated to the condyalr path and three were no significant differences between right and left side of the anterior slope of articular eminence, and the condyalr path angle.

  • PDF

3D Spreader Movement Information by the CCD cameras and the Laser Distance Measuring Unit

  • Lee, Bong-Ki;Lee, Jung-Jae;Kim, Sang-Ju;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.241-245
    • /
    • 2003
  • This paper introduces a method that can derive information about the movement of a spreader and skew in order to drive ALS(Automatic Landing System) in the crane used at a harbor. Some methods that use LDL Corner detectors a kind of 2D Laser scanner sensor or Laser distance measuring units to obtain the information in ALS are used presently. But these have some defects in economic efficiency and performance. Therefore, to correct these defects, we propose a method to acquire the information for the movement of a spreader, skew and sway angle using CCD camera image data and Laser distance measuring unit data.

  • PDF

A Study on the Estimation of Smartphone Movement Distance using Optical Flow Technology on a Limited Screen (제한된 화면에 광류 기술을 적용한 스마트폰 이동 거리 추정에 관한 연구)

  • Jung, Keunyoung;Oh, Jongtaek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.71-76
    • /
    • 2019
  • Research on indoor location tracking technology using smartphone is actively being carried out. Especially, the movement distance of the smartphone should be accurately measured and the movement route of the user should be displayed on the map. Location tracking technology using sensors mounted on smart phones has been used for a long time, but accuracy is not good enough to measure the moving distance of the user using only the sensor. Therefore, when the user moves the smartphone in a certain posture, it must research and develop an appropriate algorithm to measure the distance accurately. In this paper, we propose a method to reduce moving distance estimation error by removing user 's foot shape by limiting the screen of smartphone in pyramid - based optical flow estimation method.

Forward Vehicle Movement Estimation Algorithm (전방 차량 움직임 추정 알고리즘)

  • Park, Han-dong;Oh, Jeong-su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1697-1702
    • /
    • 2017
  • This paper proposes a forward vehicle movement estimation algorithm for the image-based forward collision warning. The road region in the acquired image is designated as a region of interest (ROI) and a distance look up table (LUT) is made in advance. The distance LUT shows horizontal and vertical real distances from a reference pixel as a test vehicle position to any pixel as a position of a vehicle on the ROI. The proposed algorithm detects vehicles in the ROI, assigns labels to them, and saves their distance information using the distance LUT. And then the proposed algorithm estimates the vehicle movements such as approach distance, side-approaching and front-approaching velocities using distance changes between frames. In forward vehicle movement estimation test using road driving videos, the proposed algorithm makes the valid estimation of average 98.7%, 95.9%, 94.3% in the vehicle movements, respectively.

Comparison of Scapular Kinematics During Active Shoulder Horizontal Adduction Between Subjects With and Without Limited Range of Motion of Shoulder Horizontal Adduction

  • Joung, Ha-na;Kim, Moon-hwan;Jeon, In-cheol;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.68-75
    • /
    • 2016
  • Background: Shoulder horizontal adduction (HA) is performed in many activities of daily living. The limited range of motion (LROM) of HA is affected by the tightness of the posterior deltoid, infraspinatus, teres major, and posterior capsule of glenohumeral joint. The LROM of shoulder HA contributes to excessive scapular abduction. Objects: The aim of this study is to compare the scapular abduction distance and three-dimensional displacement of the scapula during shoulder horizontal adduction between subjects with and without the LROM of shoulder HA. Methods: 24 subjects (12 people in LROM group and 12 people in normal ROM group) participated. Subjects with less than $115^{\circ}$ of HA ROM were included in LROM group. Shoulder HA was performed 3 times for measuring scapular abduction distance and three-dimensional displacement of the scapula. Tape measure was used for measuring scapular abduction distance. Scapular abduction distance was normalized by dividing the scapular size. Polhemus Liberty was used for measuring the three-dimensional displacement of the scapula. Results: Normalized scapular abduction distance was significantly greater in LROM group than normal ROM group (p<.001). Three-dimensional displacement of the scapula during shoulder HA was greater in LROM group than normal ROM group (p<.05). Conclusion: LROM group had a greater scapular abduction and three-dimensional displacement of the scapula during shoulder HA compared to normal ROM group.

Effect of Body Posture on the Rest Position and the Rotational Torque Movement of the Mandible (신체 자세의 변화가 하악의 안정위와 비틀림 회전운동에 미치는 영향)

  • Jung, Seung-Ah;Han, Kyung-Soo;Park, Mi-Sung;Yang, Keun-Young
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.383-394
    • /
    • 2000
  • This study was performed to investigate the effect of change of body posture on the rest position and the rotational torque movement of the mandible. Thirty dental students without any signs and symptoms of temporomandibular disorders and with natural dentition were selected for this study. Cervical inclination and the amount of the mandibular movement on protrusion, on left and right excursion, and on tapping in three body postures such as sitting position, supine position without pillow, and supine position with pillow were measured by goniometer, Cervical-Range-of-$Motion^{(R)}$, and mandibular tracking device, $BioEGN^{(R)}$ with $Rotate!^{(R)}$ program. The data obtained were classified and processed according to body posture and type of lateral guidance with SPSS windows program and the results were as follows: 1. There was significant difference among the three cervical inclinations by body postures. 2. Comparison of mandibular rest positions among body postures showed significant difference only for lateral distance in frontal plane, but comparison between before and after swallowing showed significant difference except for the lateral distance, vice versa. 3. Distance and amount of the rotational torque movement on protrusion and/or lateral excursions didn't show any difference by body posture. But by both body posture and lateral guidance type, there were slightly significant difference for some items. 4. A significant difference was shown for the rotational torque movement in frontal plane on tapping by body postures, for the lateral distance in frontal plane on sitting position by lateral guidance type, and for the rotational torque movement in frontal plane by both body posture and lateral guidance type.

  • PDF