• Title/Summary/Keyword: DIAMETER DISTRIBUTION

Search Result 1,862, Processing Time 0.031 seconds

Microstructure Characteristics of Conductive Cement Mortar with Deterioration Damage (열화손상이 발생된 전도성시멘트모르타르의 미세구조 특성)

  • Kim, Young-Min;Lee, Gun Cheol;Yun, Hyun Do;Kwon, Hyun Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.195-196
    • /
    • 2021
  • The pore distribution of the cement mortar mixed with carbon nanotubes was found to have a large number of pores at (370~80)㎛, and the distribution ratio was larger as the carbon nanotubes were mixed. However, the pores with a fine particle diameter of (10-0.5) ㎛ were found to be larger as the carbon nanotubes were incorporated. However, the distribution of pores of the test specimens of conductive cement mortar with deterioration damage was found to be distributed in a number of particle diameters of (500 to 100) ㎛ and (10 to 0.5) ㎛. It is judged that the particle diameter of the internal pores increased due to the damage. However, as the mixing ratio of the test specimen with carbon nanotubes increased, the distribution of voids was relatively lower than that of plain, and it was judged to have excellent resistance to deterioration damage.

  • PDF

A study on material removal characteristics of MR fluid jet polishing system through flow analysis (유동해석을 통한 MR fluid jet polishing 시스템의 재료제거 특성 분석)

  • Sin, Bong-Cheol;Lim, Dong-Wook;Lee, Jung-Won
    • Design & Manufacturing
    • /
    • v.13 no.3
    • /
    • pp.12-18
    • /
    • 2019
  • Fluid jet polishing is a method of jetting a fluid to polish a concave or free-form surface. However, the fluid jet method is difficult to form a stable polishing spot because of the lack of concentration. In order to solve this problem, MR fluid jet polishing system using an abrasive mixed with an MR fluid whose viscosity changes according to the intensity of a magnetic field is under study. MR fluid jet polishing is not easy to formulate for precise optimal conditions and material removal due to numerous fluid compositions and process conditions. Therefore, in this paper, quantitative data on the factors that have significant influence on the machining conditions are presented using various simulations and the correlation studies are conducted. In order to verify applicability of the fabricated MR fluid jet polishing system by nozzle diameter, the flow pattern and velocity distribution of MR fluid and polishing slurry of MR fluid jet polishing were analyzed by flow analysis and shear stress due to magnetic field changes was analyzed. The MR fluid of the MR fluid jet polishing and the flow pattern and velocity distribution of the polishing slurry were analyzed according to the nozzle diameter and the effects of nozzle diameter on the polishing effect were discussed. The analysis showed that the maximum shear stress was 0.45 mm at the diameter of 0.5 mm, 0.73 mm at 1.0 mm, and 1.24 mm at 1.5 mm. The cross-sectional shape is symmetrical and smooth W-shape is generated, which is consistent with typical fluid spray polishing result. Therefore, it was confirmed that the high-quality surface polishing process can be stably performed using the developed system.

Flow Characteristics of Ejector Driven Pipe According to the Changes of Diameter Ratio and End Position (이젝터 구동관로의 직경비와 끝단의 위치 변화에 따른 유동특성)

  • Kim, Noh Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • This study conducted CFD analysis on the mean velocity vector of distribution of the ejector driven pipe while changing the inlet velocity to 1 m/s at the diameter ratio of diffuser of 1:3, 1:2.25, 1:1.8 with the end position of driven pipe at 1, 1.253, 1.333, 1.467 respectively, which used $k-{\varepsilon}$/High Reynolds Number for the turbulence model, SIMPLE method for the analysis algorithm, and PIV experiment to verify the CFD analysis. As a result of the CFD analysis the optimum diameter ratio of ejector driven pipe was 1:3, the optimum end position of driven pipe was 1.333 for the diameter ratio of 1:3, 1:2.25, 1:1.8 and the PIV experiment obtained the same result as the CFD analysis. Therefore, the numerical analysis of the flow characteristics of ejector can be used for the optimum design implementation on ejector system.

A Secure and Fast Session Key Distribution Mechanism in Diameter Mobile IP Environment (Diameter Mobile IP 환경에서 안전하고 빠른 세션키 분배 메커니즘)

  • Song, Ji-Eun;Cho, Gi-Hwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05c
    • /
    • pp.2109-2112
    • /
    • 2003
  • Diameter-MIPV4 프로토콜은 기존 Mobile IP(MIP)의 취약한 키 분배 문제를 해결하고 이동노드에 대해 인증 및 권한 검증, 과금 서비스 등을 지원함으로써 보다 개선된 보안 메커니즘을 제안하고 있다. 그러나 흠 망의 Diameter 서버에 의해 인증 및 등록이 수행된 후 공중망을 통해서 이동노드에게 세션키를 분배하는 것은 많은 보안상 공격에 노출될 수 있으며 원격지 도메인간의 빈번한 등록 메시지 교환은 통신 지연을 야기 시킬 수 있다. 본 논문에서는 안전한 세션키 분배를 위해서, 이동 노드의 등록 수행 과정 중 홈 망과 방문 망 사이에 IPsec(IP security) 터널을 구축함으로써 공중망에서의 세션키 유출 위협을 감소시켰다. 또한 네트워크의 계층성과 Micro-Mobility MIP 메커니즘을 이용하여 동일 도메인 내에서의 핸드오프 시 이동 노드의 인증 및 등록, 세션키 분배를 지역화 함으로써 통신 지연 문제를 효율적으로 개선하였다.

  • PDF

Pore Structure of Non-Sintered Cement Matrix (비소성 시멘트 경화체의 공극구조)

  • Mun Kyoung-Ju;Park Won-Chun;Soh Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.329-332
    • /
    • 2004
  • This study aims to manufacture non-sintering cement(NSC) by adding phosphogypsum(PG) and waste lime(WL) to granulated blast furnace slag(GBFS) as sulfate and alkali activators. This study also investigates the pore structure of NSC Matrix. The result of experiment of pore structure properties, showed no considerable difference for total pore volume by cement mixing ratio but shows a large distinction in distribution of pore diameter. On the whole, pore-diameter of paste of NSC show that occupation ratio of pore diameter below 10mm is larger and is smaller than OPC and BFSC at pore diameter of over 10nm. Such a reason is that the hydrate like CSH gel and ettringite formed dense pore structure of NSC matrix.

  • PDF

Growth characteristics by age measurement of Prunus yedoensis on Jeju Island, Korea (제주도 자생 왕벚나무의 연륜생장 특성 분석)

  • Seo, Yeon Ok;Kim, Chan-Soo;Song, Gwan Pil;Jung, Sung Cheol
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.555-560
    • /
    • 2018
  • This study conducted to analyze the growth characteristics of old Prunus yedoensis on Jeju island. The diameter growth per year was measured using a DTRS-2000 instrument. The DBH, ground DBH and height of the investigated P. yedoensis were 137 cm, 143 cm, and 15.5 m, respectively. Our analysis showed that the age of the old P. yedoensis was 93 years. An annual diameter growth of $2.85mm{\pm}0.96$ was observed. The result of age estimation, about $265{\pm}64$ years in P. yedoensis on Jeju island. This information could be useful to understand the annual diameter growth characteristics the P. yedoensis distributed on Jeju island.

Flow Distribution Characteristics in a Multi-Pass Heat Exchanger (다패스 열교환기에서의 유량분배 특성)

  • Kim, Min-Soo;Kang, Soo-Jin;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.737-742
    • /
    • 2006
  • This paper numerically investigates to evaluate the performance according to the number of passes and the inlet/outlet diameter in a multi-pass multi-branch heat exchanger. A JF factor is used as an evaluation characteristic value to consider the heat transfer rate and the pressure drop simultaneously. It estimates the performance according to the number of passes and the inlet diameter of the reference heat exchanger. When the ratio of the inlet diameter to the header height is about 0.5, the optimum number of passes is selected along with the inlet diameter.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

Experimental Study of Molten Wood's Metal Jet Breakup in Subcooled Water (과냉각수조 내의 제트에 의한 용융우드메탈 미립화에 관한 실험적 연구)

  • Heo, Hyo;Jerng, Dong Wook;Bang, In Cheol
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.197-203
    • /
    • 2014
  • The liquid jet breakup has been studied in the areas such as aerosols, spray and combustion. The breakup depends on several physical parameters such as the jet velocity, the nozzle inner diameter, and the density ratio of the water to the jet. This paper deals with characteristics of the jet breakup according to the jet velocity and the nozzle diameter. In order to consider only hydrodynamic factors, all the experiments were conducted in non-boiling conditions. The jet behavior in the water pool was observed by high-speed camera and PIV technique. For the condition of the inner diameter of 6.95 mm and the jet velocity of 2.8 m/s, the debris size of 22 mm gave the largest mass fraction, 39%. For higher jet velocity of 3.1 m/s, the debris size of 14 mm gave the largest mass fraction, 36%. For the nozzle with inner diameter of 9.30 mm, the debris size distribution was different. For jet velocity of 2.8 m/s and 3.1 m/s, the debris size with the largest mass fraction was found to be 14 mm. It was identified that the debris size decreased as the diameter or the jet velocity increased.

A RADIOGRAPHIC STUDY ON PERIAPICAL LESIONS (치근단병소에 관한 방사선학적 연구)

  • Bae Keum-Bok;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.109-118
    • /
    • 1991
  • The author studied the age distribution, etiology, affected site and several radiographic features of periapical granulomas, cysts, and abscesses. The material consisted of 928 films obtained from the patients who were diagnosed and treated under the diagnosis of periapical granulomas, cysts, and abscesses during the past 8 years (1979-1986) at the Infirmary of Dental School, Chosun University. The obtained results were as follows: 1. The order of incidence was as follows: periapical abscess (67.2%), granuloma, and cyst. 2. The age distribution revealed the highest incidence around the age of 30 and relatively higher incidence over the age of 60 in the case of periapical abscess and granuloma. 3. In the frequency of location: Periapical abscesses occured most frequently in the mandibular molars. Granulomas showed relatively higher incidence in maxilla than in mandible. Cysts were most common in the maxillary anterior teeth. 4. The mean diameter of dental granuloma was 5.9㎜, however, all dental granulomas were less than 9.3㎜ in diameter. The mean diameter of periapical cyst was l3.8㎜. 5. Periapical cyst revealed well circumscribed radiolucent lesions and 77.8% of the lesion showed white line. 86.0% of dental granuloma showed well circumscribed border, 54.5% sclerosis on surrounding bone and 38.5% partial white line. Periapical abscess revealed diffuse radiolucent lesion, 89.6% of the lesions had sclerosis on surrounding bone, and 38.0% sinus tract.

  • PDF