• Title/Summary/Keyword: DF

Search Result 1,194, Processing Time 0.027 seconds

Effects of Pressure Ratio on Population Inversion in a DF Chemical Laser with Concurrent Lasing

  • Park, Jun-Sung;Baek, Seung-Wook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.287-293
    • /
    • 2004
  • A numerical simulation is presented for investigating the effects of pressure ratio of $D_2$ injector to supersonic nozzle on the population inversion in the DF chemical laser cavity, while a lasing concurrently takes place. The laser beam is generated between the mirrors in the cavity and it is important to obtain stronger population inversion and more uniform distribution of the excited molecules in the laser cavity in order to produce high power laser beam with good quality. In this study, these phenomena are investigated by means of analyzing the distributions of the DF excited molecules and the F atom used as an oxidant, while simultaneously estimating the maximum small signal and saturated gains and power in the DF chemical laser cavity. For the numerical solution, an 11-species (including DF molecules in various excited states of energies), 32-step chemistry model is adopted for the chemical reaction of the DF chemical laser system. The results are discussed by comparison with two $D_2$injector pressure cases; 192 torr and 388.64 torr. Major results reveal that in the resonator, stronger population inversions occur in the all transitions except DF(1)-DF(0), when the $D_2$injection pressure is lower. But, the higher $D_2$injection pressure provides a favorable condition for DF(1)-DF(0) transition to generate the higher power laser beam. In other words, as the pressure of $D_2$injector increases, the maximum small signal gain in the $V_{1-0}$ transition, which is in charge of generating most of laser power, becomes higher. Therefore, the total laser beam power becomes higher.r.

  • PDF

Grapefruit Seed Extract (DF-100) Treatment of Poultry to Reduce Attached Salmonella

  • Mike F. Slavik;Kim, Jeong-Weon;Phil L. Matsler;Hong Wang
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.1
    • /
    • pp.7-10
    • /
    • 1996
  • Chicken skins or carcasses inoculated with Salmonella typhimurium were exposed to 0.1 or 0.5% grapefruit seed extracts (DF-100) for 1 or 3 min to evaluate antibacterial activity of DF-100 and its possible application in proultry processing. The numbers of live salmonellae on chicken skins were reduced by 0.8-1.2 logs/cm2 with 0.5% DF-100. Dipping chicken carcasses into 0.5% DF-100 for 3 min reduced salmonelae by 4.3 logs/carcass. Scanning electron microscopy showed that DF-100 killed the cells attached but did not detach cells from the skin. No odor or changes in the color of chicken skin were detected after DF-100 treatment.

  • PDF

Parallel Deblocking Filter Based on Modified Order of Accessing the Coding Tree Units for HEVC on Multicore Processor

  • Lei, Haiwei;Liu, Wenyi;Wang, Anhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.3
    • /
    • pp.1684-1699
    • /
    • 2017
  • The deblocking filter (DF) reduces blocking artifacts in encoded video sequences, and thereby significantly improves the subjective and objective quality of videos. Statistics show that the DF accounts for 5-18% of the total decoding time in high-efficiency video coding. Therefore, speeding up the DF will improve codec performance, especially for the decoder. In view of the rapid development of multicore technology, we propose a parallel DF scheme based on a modified order of accessing the coding tree units (CTUs) by analyzing the data dependencies between adjacent CTUs. This enables the DF to run in parallel, providing accelerated performance and more flexibility in the degree of parallelism, as well as finer parallel granularity. We additionally solve the problems of variable privatization and thread synchronization in the parallelization of the DF. Finally, the DF module is parallelized based on the HM16.1 reference software using OpenMP technology. The acceleration performance is experimentally tested under various numbers of cores, and the results show that the proposed scheme is very effective at speeding up the DF.

Soybean Growth and Yield as Affected by Spacing of Drainage Furrows in Paddy Field

  • Cho, Jin-Woong;Lee, Jung-June;Oh, Young-Jin;So, Jung-D.;Won, Jun-Yeon;Kim, Chang-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.1
    • /
    • pp.26-31
    • /
    • 2006
  • This study was conducted to determine the optimum number of inter-rows according to distance of drainage furrow (DF) for running-off excessive-water stress (EWS) in paddy field. The most soil water potential was shown in high ridge (distance of DF by 70 cm) cultivation and the soil water potential showed increasing tendency in over four inter-rows cultivation by DF. The growth of soybean reduced by extended inter-row and its reducing level was high, especially, over four inter-rows (DF distance by 2.8 m) because of EWS. The photosynthetic rate decreased in the more extensive field by distance of DF at V5 and R2 stages, especially, in over four interrows cultivation. Also, root activity decreased at wider DF. The yield was reduced with wider distance of DF more extensively, the highest yield of 270 g per $m^2$ at the every row, but yield showed decreasing tendency at over the $4^{th}$ row (2.8 m) cultivation. Soybean cultivation in paddy field could be founded with DF of every other or $4^{th}$ row.

Outage Analysis of OFDM-Based Dual-hop Multi-Relay Systems with Best Relay Selection (최선 릴레이 선택을 적용한 OFDM 기반 이중-홉 다중 릴레이 시스템의 아웃티지 성능 분석)

  • Park, Jae-Cheol;Wang, Jin-Soo;Lee, Ji-Hye;Kim, Yun-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.5C
    • /
    • pp.487-494
    • /
    • 2010
  • This paper presents an OFDM-based dual-hop multi-relay system with best relay selection maximizing the mutual information. For the system either with decode-and-forward (DF) relays or with amplify-and-forward (AF) relays, we derive a lower-bound on the outage probability and the diversity order achievable in frequency selective fading channels and provide the outage capacity from simulation. Performance evaluation shows that both DF and AF provide the same diversity order as in the lower-bound but DF of which the outage probability is much closer to the lower-bound provides a better outage capacity than AF. It is also observed that the SNR gain of DF over AF gets larger as either the number of resolvable multipaths or the number of relay candidates increases, which makes DF relaying more favorable to the OFDM-based multi-relay system.

Analytical method of PCDDs/PCDFs in blood using NIST SRM 1589a (인증표준물질(NIST SRM 1589a)을 이용한 혈액 중 다이옥신 분석방법)

  • Shin, Sun Kyoung;Park, Seok Un;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.559-567
    • /
    • 2005
  • For the analytical method of PCDD/Fs in blood, which have been issued recently, SRM 1589a of NIST(National Institute of Standards and Technology) was used and a practical analytical method of PCDD/Fs in blood was presented through comparison of methods of Canada and Japan. The proposed method used alkali-digestion extraction for removal of the lipid effectively using two capillary columns. The limit of quantification of TeCDD/DF and PeCDD/DF was 1 pg/g-lipid, HxCDD/DF and HpCDD/DF was 2 pg/g-lipid, OCDD/DF was 4 pg/g-lipid. With consideration the range of detected concentration, calibration standards were presented as $CS_L$(0.1~1), $CS_1/2$(0.25~2.5), $CS_1$(0.5~5.0), $CS_2$(2~20), $CS_3$(10~100).

An Accurate Direction Finding Technology Using a Phase Comparison and Time Difference of Arrival (위상비교와 시간차를 복합한 정밀 방향탐지 기술)

  • Lim, Joong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5208-5213
    • /
    • 2011
  • In this paper, we proposed a new direction finding(DF) technology using TDOA(time-difference of arrival) and PDOA(phase difference of arriving signal) method. The proposed technology has a good DF accuracy without DF ambiguity. TDOA or PDOA technology is used to the most of intelligence systems in 21 century. The principle of TDOA is to receive a signal with two parallel antennas, measure the time difference of arrival signal, and converse the time difference to the direction of incident signal. Those technology make a DF system small size but the DF accuracy is low into short antenna installation distance. The principle of PDOA is similar to TDOA except measuring the phase difference of arrival signal, These technology get a good DF accuracy in short antenna installation distance but have a DF ambiguity. The proposed DF method is simulated into DF system operation environment with noise, and has a good DF accuracy.

Dual Fuel Generator Modeling and Simulation for Development of PMS HILS (PMS HILS 구축을 위한 Dual Fuel Generator 모델링 및 시뮬레이션)

  • Hwang, Joon-Tae;Hong, Suk-Yoon;Kwon, Hyun-Wung;Lee, Kwang-Kook;Song, Jee-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.613-619
    • /
    • 2017
  • In this paper, DF(Dual Fuel) Generator modeling, which uses both conventional diesel fuel and LNG fuel, has been performed and monitoring system has been developed based on MATLAB/SIMULINK for the development of PMS(Power Management System) HILS(Hardware In the Loop Simulation). The principal components modeling of DF Generator are DF engine which provides the mechanical power and synchronous generator which convert the mechanical power into electrical power. Submodels, such as throttle body, intake manifold, torque generation and mass of LNG and diesel Quantity are used to perform DF engine. Also, governor is used for load sharing between paralleled DF generators to share a total load that exceeds the capacity of a single generator. To verify modeling of DF Generator designated ship lumped load Simulation is carried out. A validity of DF Generator has been verified by comparison between simulation results and estimated result from the designated lumped load.

PLAQUE ADHESION ON THE SURFACES OF VARIOUS COMPOSITE RESIN (수종 복합레진에 대한 치태 부착도 비교)

  • Kim, Young-Jong;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.547-554
    • /
    • 2004
  • The surface characteristics of restoration such as surface roughness and droplet contact angle are important part for the process of bacterial adhesion. The purpose of this study is to compare plaque adhesion by measuring roughness, droplet contact angle, and amount of accumulated plaque on the surfaces of composite resins. Four kinds of composite resins, Z-100(Z1), Durafil(DF), Filtek supreme(FS), Clearfil AP X(CA) were used. Ten samples were divided into unpolished and polished group. Surface roughnesses and droplet contact angles were measured by profilometer and goniometer. Plaque weight gains are measured. The results were as follows: 1. The experimental group were rougher than the control group. Surface roughnesses were decreased in the following order; (Z1, DF, CA)>FS in the control group, and CA>Z1>(FS, DF) in the experimental group(P<0.05). 2 The control group showed larger contact angle than the experimental group. Contact angles were decreased in the following order; CA>(FS, DF, Z1) in the control group, and (CA, DF)>(FS, Z1) in the experimental group(P<0.05). 3. The experimental group showed more much plaque than the control group. The amounts of plaque accumulation in vitro were decreased in the following order; Z1>(DF, FS)>CA in the control group, and Z1>FS>(CA, DF) in the experimental group. The latter showed more much plaque than the former(P<0.05). 4. There were stronger correlation between plaque deposition and contact angle (P<0.05) than that of plaque deposition and surface roughness.

  • PDF

Comparison and evaluation of 89Zr-labeled trastuzumab and Thio-trastuzumab : a potential immuno-PET probe for HER2-positive carcinomas

  • Un Chol Shin;Seoku Bae;Suk-man Kim;Min-Woo Lee;Han Sang Jin;Hyun Park;Kyo Chul Lee;Jung Young Kim;Ji Woong Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.105-111
    • /
    • 2021
  • 89Zr is a positron-emitting radioisotope, which has known as well-suited radioisotope for use in a monoclonal antibody-based imaging agent for immuno-PET. The purpose of this study was to quantitatively evaluate the diagnostic ability of general trastuzumab and thio-trastuzumab as HER2 positive receptors based on Df hexadentate iron chelator. Desferrioxamine-p-SCN (Df-Bz-NCS) and desferroixamine-maleimide (Df-Mal) were purchased from Macrocyclics (Dallas, TX, USA). The trastuzumab was purchased from Roche (Schweiz), and thio-trastuzumab was obtained from professor Hyo-Jeong Hong group (Kangwon National University). The radioisotope 89Zr was produced by domestic purification system and KIRAMS using medical cyclotron (50 MeV, Scantronix). The conjugates of Df-trastuzumab and Df-thio-trastuzumab were prepared with Df-Bz-NCS and Df-Mal under basic aqueous solution (pH 8-9) at room temperature, respectively. The conjugates purified by PD-10 column were mixed with dried 89Zr chloride. 89Zr-labeled conjugates were purified and concentrated by Amicon ultra centrifugal filter. The preparation step and time of 89Zr-labeled conjugates was shorted as 4 steps within 2 hours. 89Zr-labeled conjugates showed the highly radiochemical purity of over 98%, and were very stable until 7 days by the analysis of radio-ITLC method. Each radio-labeled conjugates were also exhibited the highly stability in both PBS buffer and mouse serum. Immuno-PET imaging of 89Zr-labeled conjugates in mice bearing gastric cancer xenograft tumors with HER2 expression showed high tumor uptake in the NCI-N87 HER2-expressing. However, 89Zr-Df-Mal-thio-trastuzumab showed a relatively lower tumor-to-background ratio than 89Zr-Df-Bz-trastuzumab, as well as whole-body distribution. In the results, 89Zr-Df-Bz-trastuzumab was evaluated to have a relatively higher HER2 diagnostic ability than 89Zr-Df-Mal-thio-trastuzumab.