• Title/Summary/Keyword: DETERIORATION TYPE

Search Result 510, Processing Time 0.024 seconds

Development of Dome-Type Cold Storage Facility Using 3-D CFD Simulation (3차원 CFD 시뮬레이션을 이용한 돔형 저온저장고 개발)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • This study was conducted to develop proper model for cold storage facility that could of for uniform heat movement and air movement f3r green grocery and improve improper design of the existing container-type cold storage facility. For that reason, new model(dome-type) cold storage facility was developed using 3-D CFD(computational fluid dynamics) simulation. The size was 6m${\times}$6m${\times}$5m. Its size and configuration were same to simulation model. Unit cooler was designed to send cold air in 4 side ways. A dome-type cold storage facility showed uniform distributions of air temperature and velocity because cold air was forced to move down along the ceiling and the wall and then circulated to the unit cooler from the central part of the floor. Dome-type cold storage facility also showed by low wind velocity, below 1 m/s that could minimized cold damage and quality deterioration.

Oil Absorption Effects of Organic Porous Materials (유기 다공성 소재의 흡유 효과)

  • Kang, Young-Goo;Han, Sang-Bum
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.86-91
    • /
    • 2006
  • Oil spills caused by the accidents have been occurred from house and factory waste, grounded tanker, the rupture of storage tank and oil pipelines, the deterioration of various industrial facilities, etc. Many oil spills result in contamination of shorelines and workplace. Fire and explosion may happen from these spills. There are several technologies used for clean-up application, which include use of oil dispersing agents, absorbents, solidifiers, booms and skimmers by physical, chemical, and biological methods. Methods for oil spill clean-up operation are classified into the absorption type, gel type and self-swelling type. Porous materials with oil absorptive properties are classified into micropore, mesopore, and macropore depending on their pore sizes. Recently, new porous materials with smaller size have been developed, but the selective oil absorption in water-in-oil interface demonstrates the macro pore size. In this study oil absorption effects were evaluated using the organic porous materials with a complex function of gel type and swelling type. Samples were subjected to analysis by FT-IR spectroscopy and were characterized in terms of gel formation and morphologies. Oil sorption capacity, pressure retention force and gel strength were also measured. From these results, the physicochemical reactivity before and after gelation was verified and the industrial applications of clean-up operation were suggested.

Capacitive Sensor for in situ Measurement of Deterioration of Car Engine Oil (자동차 엔진오일 열화상태 in situ 측정용 전기용량 센서)

  • Lee, R.D.;Kim, H.J.;Semenov, Yu. P.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.266-272
    • /
    • 2001
  • A coil-type capacitive sensor on which the deterioration of the car engine oil can be in situ measured, has been developed. The sensor was designed to get over 10 pF at the limited space on the drain hole of the oil pan. The design factors for stable capacitance measurement such as coil diameter and winding condition, materials and configuration of the coil former, and shielding method, etc., were known by both computer simulation and experimental investigations. The dielectric properties measured by several sensors for an used sample oil were consisted within 0.25%. The sensor installed on the car having severe vibration, temperature and humidity fluctuation, even electromagnetic noise, has shown very distinguishable results.

  • PDF

Heating Energy Consumption Analysis of the Apartment Applied District Heating System (지역난방 공동주택의 단지별 난방사용량 분석 연구)

  • Park, Sun-Hyo;Lee, Hyun-Jung;Kwon, Kyung-Woo;Lee, Byung-Seok;Kim, Yang-Sub
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.293-298
    • /
    • 2012
  • The purpose of this study is performance validation of district heating apartments about heating energy consumption and analysis of energy consumption by unit characteristics. The heating energy consumption of the existing apartments was analyzed and the analyzed results will be used for energy saving technology development and policy making. The heating energy consumption data about total 78 apartment complexes, 56,910 units in Gangnam-Gu, Seoul, Korea were investigated from October, 2010 to April 2011. The analysis results are as follows; The mean heating energy consumption is 98[kWh/m2]. The energy consumption of Apgujung-Dong, Daechi-Dong is higher than that of mean valuse. The energy consumption deviation by deterioration, unit area, core type and regional group is very high. Specially, building deterioration casts a long shadow.

  • PDF

Development of Uncertainty-Based Life-Cycle Cost System for Railroad Bridges (불확실성을 고려한 철도 교량의 LCC분석 시스템 개발)

  • Cho, Choong-Yuen;Sun, Jong-Wan;Kim, Lee-Hyeon;Cho, Hyo-Nam
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1158-1164
    • /
    • 2007
  • Recently, the demand on the practical application of life-cycle cost effectiveness for design and rehabilitation of civil infrastructure is rapidly growing unprecedentedly in civil engineering practice. Accordingly, it is expected that the life-cycle cost in the 21st century will become a new paradigm for all engineering decision problems in practice. However, in spite of impressive progress in the researches on the LCC, so far, most researches in Koreahave only focused on roadway bridges, which are not applicable to railway bridges. Thus, this paper presents the formulation models and methods for uncertainty-based LCCA for railroad bridges consideringboth objective statistical data available in the agency database of railroad bridges management and subjective data obtained form interviews with experts of the railway agency, which are used to anew uncertainty-based expected maintenance/repair costs including lifetime indirect costs. For reliable assessment of the life-cycle maintenance/repair costs, statistical analysis considering maintenance history data and survey data including the subjective judgments of railway experts on maintenance/management of railroad bridges, are performed to categorize critical maintenance items and associated expected costs and uncertainty-based deterioration models are developed. Finally, the formulation for simulation-based LCC analysis of railway bridges with uncertainty-based deterioration models are applied to the design-decision problem, which is to select an optimal bridge type having minimum Life-Cycle cost among various railway bridges types such as steel plate girder bridge, and prestressed concrete girder bridge in the basic design phase.

  • PDF

A Study on Early Age Shrinkage of Concrete using Recycled Aggregate (재생골재를 사용한 콘크리트의 초기재령 수축에 관한 연구)

  • Koo, Bong-Kuen;Seo, Sang-Gu;Rha, Jae-Woong;Park, Jae-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.159-167
    • /
    • 2003
  • Cracks in reinforced concrete structures reduce overall durability by allowing the penetration of water and aggressive agents, thereby accelerating the deterioration of the reinforcing steel. Highway pavement and bridge decks are especially susceptible to this type of deterioration since these structures exhibit high rates of shrinkage and are frequently exposed to aggressive environmental conditions. The objectives of this investigation included the development of experimental procedures for assessing shrinkage cracking potential of recycled aggregate concrete, the evaluation of mix composition on shrinkage cracking potential, and the development of theoretical models to simulate early-age cracking behavior. Specifically, the influences of shrinkage-reducing admixture(SRA) and recycled aggregate concrete were investigated. The shrinkage-reducing admixture substantially reduces free shrinkage and restrains shrinkage cracking while providing similar mechanical properties. A fracture mechanics modeling approach was developed to predict the behavior of a variety of restrained concrete specimens. This modeling approach was used to successfully explain experimental results from a variety of mixture compositions. The model was used to demonstrate the influence of material and structural properties on the potential for cracking.

A New Noise Reduction Method Based on Linear Prediction

  • Kawamura, Arata;Fujii, Kensaku;Itho, Yoshio;Fukui, Yutaka
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.260-263
    • /
    • 2000
  • A technique that uses linear prediction to achieve noise reduction in a voice signal which has been mixed with an ambient noise (Signal to Noise (S-N) ratio = about 0dB) is proposed. This noise reduction method which is based on the linear prediction estimates the voice spectrum while ignoring the spectrum of the noise. The performance of the noise reduction method is first examined using the transversal linear predictor filter. However, with this method there is deterioration in the tone quality of the predicted voice due to the low level of the S-N ratio. An additional processing circuit is then proposed so as to adjust the noise reduction circuit with an aim of improving the problem of tone deterioration. Next, we consider a practical application where the effects of round on errors arising from fixed-point computation has to be minimized. This minimization is achieved by using the lattice predictor filter which in comparison to the transversal type, is Down to be less sensitive to the round-off error associated with finite word length operations. Finally, we consider a practical application where noise reduction is necessary. In this noise reduction method, both the voice spectrum and the actual noise spectrum are estimated. Noise reduction is achieved by using the linear predictor filter which includes the control of the predictor filter coefficient’s update.

  • PDF

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

Deterioration Evaluation Method of Noise Barriers for Managements of Highway (고속도로 방음벽 유지관리를 위한 방음벽 노후도 평가 방안)

  • Kim, Sangtae;Shin, Ilhyoung;Kim, Kyoungsu;Kim, Daae;Kim, Heungrae;Im, Jahae;Lee, Jajun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.4
    • /
    • pp.387-399
    • /
    • 2019
  • This research aimed to prepare the classification of the damage types and the damage rating system of noise barriers for expressway noise barriers and to develop deterioration evaluation method of noise barriers by reflecting them. The noise barrier consists of soundproof panels, foundations and posts and the soundproof panels with 10 different types of materials are used in a single or mixed form.In this paper, damage of soundproof panel shows a single or composite damage, and thus a evaluation model of deterioration has been developed for noise barriers that can reflect the characteristic of noise barriers. Materials used mainly for soundproof walls were divided into material types for metal, plastic, timber, transparent and concrete. And damage types for noise barrier were classified into corrosion, discoloration, deformation, spalling and dislocation and damage types were subdivided according to the noise barrier's components and materials. Damage rating was divided into good, minor, normal and severe for each major part of noise barrier to assess damage rating of soundproof panel, foundation and post. The deterioration degree of noise barrier was evaluated comprehensively by using the deterioration evaluation method of whole noise barrier using weighted average. Deterioration evaluation method that can be systematically assessed has been developed for noise barrier using single or mixed soundproof panel and noise barrier with single or complex damage types. Through such an evaluation system, it is deemed that the deterioration status of noise barrier installed can be systematically understood and utilized for efficient maintenance planning and implementation for repair and improvement of noise barriers.

Development of Block type Inlet Distortion Simulating Device for Gas Turbine Engine Inlet Distortion Test

  • Lee, Kyung-Jae;Lee, Bo-Hwa;Kang, Sang-Hun;Jung, Jae-Hong;Yang, Soo-Seok;Lee, Dae-Sung;Kwak, Jae-Su
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.121-125
    • /
    • 2007
  • In late 1960's, engineers of the engine manufacturer experienced that the distortion of inlet flow of turbofan and turbojet engine could cause the surge in compressor and affect overall engine operational performance, which result in the deterioration of stability of the engine. In this study, block type of inlet distortion simulating device has been developed in order to investigate the effect of inlet distortion on the deterioration of overall engine operational performance. The inlet distortion simulating device was installed in front of engine inlet in order to simulate distortion of inlet flow. The degree of inlet distortion was measured by rakes installed upstream the inlet distortion simulating device and between the engine inlet and inlet distortion simulating device. Before applying the inlet distortion simulating device to real engine, preliminary tests were performed with a simulated engine in order to verify the degree of inlet distortion by the device. Preliminary inlet distortion tests were performed in Altitude Engine Test Facility(AETF) of Korea Aerospace Research Institute(KARI) and results showed that the inlet distortion simulating device could be used in simulating various inlet distortion cases.