• 제목/요약/키워드: DEM resolution

검색결과 302건 처리시간 0.026초

간략모형식의 에피폴라 기하 생성 및 분석 (Epipolar Geometry of Alternative Sensor Models for High-Resolution Satellite Imagery)

  • 정원조;김의명;유복모;유환희
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.179-184
    • /
    • 2004
  • High-resolution satellite imagery are used in various application field such as generation of DEM, orthophto, and three dimensional city model. To define the relation between image and object space, sensor modelling and generation of the epipolar image is essential processes. As the header information or physical sensor model becomes unavailable for the end users due to the national security or commercial purpose, generation of epipolar images without these information becomes one of important processes. In this study, epipolar geometry is generated and analysed by applying two generalized sensor models; parallel and parallel-perspective model Epipolar equation of the parallel model has linear property which is relatively simple; Epipolar geometry of the parallel-perspective model is non-linear. This linear property enable us to generate epipolar image efficiently.

  • PDF

Implementation of a SAR GeoCoding Module based on component

  • Kim, Kwang-Yong;Jeong, Soo;Kim, Kyung-Ok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.337-339
    • /
    • 2003
  • This paper describes the SAR geocoding module, which is the sub-module of a IRHIS ('Integrated RS s/w for High resolution satellite ImageS'): package of 'Development of High Resolution Satellite Image Processing Technique' project in Electronics and Telecommunications Research Institute (ETRI). The function of this module is following. 1) Orbit Type : ERS1/ERS2, RADARSAT 2) Data Format : SAR CEOS Format(Single Look Complex) 3) Function: - Geocode : Generate a map projected SAR image based on only orbit information - Orthorectify: Generate a rigorous geocoded SAR image with a DEM information In this paper, we briefly describe the algorithm that is adopted to the functions, and component architecture.

  • PDF

Generation Of High-Resolution Precise Dems Of The Antarctic Dry Valleys And Its Vicinity Based On Lidar Surveys

  • Lee, Impyeong;Park, Yunsoo;Park, Hong-Gi;Cho, Young-Won
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 Korea-Russia Joint Conference on Geometics
    • /
    • pp.38-44
    • /
    • 2004
  • NASA, NSF and USGS jointly conducted LIDAR surveys to acquire numerous surface points with high densities over the Antarctic Dry Valleys and its vicinity. The huge set of the points unusually includes many blunders, retaining large variation of the point densities. Hence, to reduce the undesirable effects due to these characteristics and process the huge number of points with reasonable time and resources, we developed an efficient, robust, nearly automatic approach to DEM generation. This paper reports about the application of this approach to generating high-resolution precise DEMs from the Antarctic LIDAR surveys and the evaluation of their accuracy.

  • PDF

유량과 지형조건에 따른 Flo-2D에서의 토석류 확산 민감도 분석 (Sensitivity Analysis of Debris Flow Simulation in Flo-2D Using Flow Discharge and Topographic Information)

  • 김남균;전병희
    • 지질공학
    • /
    • 제32권4호
    • /
    • pp.547-558
    • /
    • 2022
  • 2020년 8월 집중호우로 인하여 전라남도 곡성지역에 토석류가 발생하여 5명이 사망하는 재난이 발생하였다. 이 지역을 대상으로 하여 사진 측량을 통해 0.03 m의 고해상도 지형정보를 구축하고 토사의 붕괴량을 측정하였다. 또한 Flo-2D를 이용하여 토석류의 유량과 지형정보의 차이에 따라 유동심, 유속, 확산면적에 대하여 민감도 분석을 수행하였다. 유량이 높아질수록 토석류의 유동심, 유속, 확산면적이 높아지며 고해상도 지형정보와 저해상도 지형정보와의 결과 차이도 높아지는 것으로 나타났다. 그리고, 고해상도의 지형정보를 적용하였을 때 실제의 토석류 흐름방향과 유사하게 계산되어 고해상도 지형정보의 적용이 토석류 해석 결과의 정확성을 높이는 결과를 정량적으로 분석하였다. 추가로 항복응력과 점성과 같은 지질정보에 대해 고려하면 전반적으로 실제 토석류의 확산 정보보다 작게 계산된 결과를 보완할 수 있을 것으로 판단된다.

GOCI-II를 활용한 단기 연안지형변화 모니터링 가능성 평가 연구 (A Study on the Possibility of Short-term Monitoring of Coastal Topography Changes Using GOCI-II)

  • 이진교;김근용;유주형
    • 대한원격탐사학회지
    • /
    • 제37권5_2호
    • /
    • pp.1329-1340
    • /
    • 2021
  • 해양과 육상사이의 전이지대인 조간대는 인위적 활동과 자연적 교란에 의해 다양한 변화가 빠르게 일어나 지속적인 모니터링이 필요하다. 원격탐사 방법을 활용한 연안지형변화 모니터링은 조간대 접근성에 대한 한계를 극복하고, 조간대의 장기적인 지형변화를 관측하는데 효과적인 것으로 평가된다. 원격탐사를 이용한 기존 연안지형 모니터링연구는 대부분 Landsat 위성시리즈와 Sentinel 위성 영상 분석을 통해 수행되었다. 본 연구는 GOCI-II(천리안 해양위성 2호)영상에서 NDWI 지수를 이용해 수륙경계선을 추출한 후 다양한 조위에 따른 경기만 일대 조간대 면적 변화를 파악하고 짧은 기간 동안 DEM제작과 지형고도변화 관측의 유용성에 대해 살펴보았다. 2020년 10월 8일부터 2021년 8월 16일까지 경기만 일대에서 획득된 영상은 GOCI-II 249장, Sentinel-2A/B 39장, Landsat 8 OLI는 7장이었다. 조간대 DEM을 제작할 경우, Sentinel과 Landsat 영상은 최소 3개월에서 1년 이상의 자료수집이 필요했지만, GOCI-II 위성은 단 하루의 자료를 이용해서 조위에 따른 경기만 일대 조간대 DEM생성이 가능하였고 조간대 노출빈도 계산을 통해 지형고도변화도 관측하였다. GOCI-II 위성을 활용해 연안지형변화를 관측시 짧은 주기의 높은 시간해상도로 지형 변화를 조기 감지하고 부족한 공간해상도는 고해상도의 다중복합자료를 이용해 정밀하게 보간하여 활용하는 방안이 좋을 것으로 생각된다. 향후, 위 결과들을 바탕으로 연구 영역을 확대하고, 자동 분석 및 탐지 가능한 기술 개발을 통해 한반도 연안의 최신 지형도와 연안관리에 필요한 정보를 빠르게 제공 가능할 것으로 기대된다.

고해상도 광학영상과 SAR영상으로부터 생성된 수치표고모델의 정확도 분석 (Accuracy Analysis of DEMs Generated from High Resolution Optical and SAR Images)

  • 김충;이동천;염재홍;이용욱
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.337-343
    • /
    • 2004
  • Spatial information could be obtained from spaceborne high resolution optical and synthetic aperture radar(SAR) images. However, some satellite images do not provide physical sensor information instead, rational polynomial coefficients(RPC) are available. The objectives of this study are: (1) 3-dimensional ground coordinates were computed by applying rational function model(RFM) with the RPC for the stereo pair of Ikonos images and their accuracy was evaluated. (2) Interferometric SAR(InSAR) was applied to JERS-1 images to generate DEM and its accuracy was analysis. (3) Quality of the DEM generated automatically also analyzed for different types of terrain in the study site. The overall accuracy was evaluated by comparing with GPS surveying data. The height offset in the RPC was corrected by estimating bias. In consequence, the accuracy was improved. Accuracy of the DEMs generated from InSAR with different selection of GCP was analyzed. In case of the Ikonos images, the results show that the overall RMSE was 0.23327", 0.l1625" and 13.70m in latitude, longitude and height, respectively. The height accuracy was improved after correcting the height offset in the RPC. i.e., RMSE of the height was 1.02m. As for the SAR image, RMSE of the height was 10.50m with optimal selection of GCP. For the different terrain types, the RMSE of the height for urban, forest and flat area was 23.65m, 8.54m, 0.99m, respectively for Ikonos image while the corresponding RMSE was 13.82m, 18.34m, 10.88m, respectively lot SAR image.

  • PDF

변화탐지를 위한 인공위성영상자료의 정밀보정에 관한 연구 (A Study on Precision Rectification Technique of Multi-scale Satellite Images Data for Change Detection)

  • 윤희천;이성순
    • 한국측량학회지
    • /
    • 제22권1호
    • /
    • pp.81-90
    • /
    • 2004
  • 인공위성 영상자료들은 촬영조건 및 센서의 특성에 따라 다른 기하학적인 왜곡을 포함하고 있을 뿐만 아니라 공간, 방사 및 분광 해상도가 상이하기 때문에 정밀한 분석 결과 산출에 어려움이 있다. 즉, 두 개 이상의 영상을 비교 분석하기 위해 기본적인 센서 정보의 차이에서 발생하는 정오차를 소거하고 지형기복에 의해 발생하는 부정오차를 제거하기 위한 정밀 기하보정은 반드시 선행되어야 한다. 본 연구에서는 인공지형지물 변화탐지 기본도 를 구축하기 위해 위성의 센서정보를 이용한 센서모델링을 실시하였고 지상기준점과DEM자료를 가지고 정밀편위수정함으로써 다른 센서 및 촬영조건에 따라 발생하는 정오차를 소거하였다. 즉, 정밀편위수정법에 의해 Kompsat EOC 영상의 기복변위량을 감소시킬 수 있었고, 변화탐지를 위해 사용된 영상의 정합성과를 도심지역, 산림지역 및 혼합지역으로 나누어 시험 지역을 선정하여 검토한 결과 모든 지역에서 약 10% 정도의 정합률이 향상됨으로써 영상의 위치정확도를 향상시킬 수 있었다. 이러한 기본도를 가지고 이루어지는 변화탐지 결과는 지형지물의 갱신이나 다양한 GIS 응용의 기본 자료로서 효율적으로 사용할 수 있을 것으로 기대된다.

Development of New Photogrammetric Software for High Quality Geo-Products and Its Performance Assessment

  • Jeong, Jae-Hoon;Lee, Tae-Yoon;Rhee, Soo-Ahm;Kim, Hyeon;Kim, Tae-Jung
    • 대한원격탐사학회지
    • /
    • 제28권3호
    • /
    • pp.319-327
    • /
    • 2012
  • In this paper, we introduce a newly developed photogrammetric software for automatic generation of high quality geo-products and its performance assessment carried out using various satellite images. Our newly developed software provides the latest techniques of an optimized sensor modelling, ortho-image generation and automated Digital Elevation Model (DEM) generation for diverse remote sensing images. In particular, images from dual- and multi-sensor images can be integrated for 3D mapping. This can be a novel innovation toward a wider applicability of remote sensing data, since 3D mapping has been limited within only single-sensor so far. We used Kompsat-2, Ikonos, QuickBird, Spot-5 high resolution satellite images to test an accuracy of 3D points and ortho-image generated by the software. Outputs were assessed by comparing reliable reference data. From various sensor combinations 3D mapping were implemented and their accuracy was evaluated using independent check points. Model accuracy of 1~2 pixels or better was achieved regardless of sensor combination type. The high resolution ortho-image results are consistent with the reference map on a scale of 1:5,000 after being rectified by the software and an accuracy of 1~2 pixels could be achieved through quantitative assessment. The developed software offers efficient critical geo-processing modules of various remote sensing images and it is expected that the software can be widely used to meet the demand on the high-quality geo products.

Accuracy evaluation of near-surface air temperature from ERA-Interim reanalysis and satellite-based data according to elevation

  • Ryu, Jae-Hyun;Han, Kyung-Soo;Park, Eun-Bin
    • 대한원격탐사학회지
    • /
    • 제29권6호
    • /
    • pp.595-600
    • /
    • 2013
  • In order to spatially interpolate the near-surface temperature (Ta) values, satellite and reanalysis methods were used from previous studies. Accuracy of reanalysis Ta was generally better than that of satellite-based Ta, but spatial resolution of reanalysis Ta was large to use at local scale studies. Our purpose is to evaluate accuracy of reanalysis Ta and satellite-based Ta according to elevation from April 2011 to March 2012 in Northeast Asia that includes various topographic features. In this study, we used reanalysis data that is ERA-Interim produced by European Centre for Medium-Range Weather Forecasts (ECMWF), and estimated satellite-based Ta using Digital Elevation Meter (DEM), Normalized Difference Vegetation Index (NDVI), difference between brightness temperature of $11{\mu}m$ and $12{\mu}m$, and Land Surface Temperature (LST) data. The DEM data was used as auxiliary data, and observed Ta at 470 meteorological stations was used in order to evaluate accuracy. We confirmed that the accuracy of satellite-based Ta was less accurate than that of ERA-Interim Ta for total data. Results of analyzing according to elevation that was divided nine cases, ERA-Interim Ta showed higher accurate than satellite-based Ta at the low elevation (less than 500 m). However, satellite-based Ta was more accurate than ERA-Interim Ta at the higher elevation from 500 to 3500 m. Also, the width of the upper and lower quartile appeared largely from 2500 to 3500 m. It is clear from these results that ERA-Interim Ta do not consider elevation because of large spatial resolution. Therefore, satellite-based Ta was more effective than ERA-Interim Ta in the regions that is range from 500 m to 3500 m, and satellite-based Ta was recommended at a region of above 2500 m.

지상기준점 정합수에 따른 정확도 분석 (Accuracy Analysis According to the Number of GCP Matching)

  • 이승웅;문두열;성우경;김재우
    • 한국지리정보학회지
    • /
    • 제21권3호
    • /
    • pp.127-137
    • /
    • 2018
  • 최근 들어 UAV(무인항공기) 및 드론을 이용하여 다양한 활용기술에 대한 연구들이 이루어지고 있다. 특히, 측량분야에서는 UAV에 탑재된 디지털 카메라나 다양한 센서들을 이용하여 취득된 고해상도의 영상자료를 바탕으로 해당 지형을 모니터링하거나, 고해상도의 정사영상 및 DSM, DEM을 생성하기 위한 기술에 관한 연구들이 수행되고 있다. 본 연구에서는 UAV와 VRS-GPS를 이용하여 GCP 정합수에 따른 정확도를 분석하여 보았다. 먼저 VRS-GPS를 이용해 지상기준점을 선점한 후 UAV를 이용하여 기본고도 150m로 촬영을 실시하였으며, 646장의 영상정보를 취득하여 DSM과 정사영상을 제작하기 위해 pix4d mapper버전을 사용하여 RMSE를 분석한 결과 GCP 정합수를 5장 이상만 하여도 국가 기본도(축척 : 1/5,000) 제작 작업규정의 오차범위를 준수하고 있어 수치지도 수정 갱신 업무까지도 충분이 활용이 가능한 것으로 판단되었다.