• Title/Summary/Keyword: DCs

Search Result 1,510, Processing Time 0.03 seconds

A Short Wavelength Coplanar Waveguide Employing Periodic 3D Coupling Structures on Silicon Substrate

  • Yun, Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.2
    • /
    • pp.118-120
    • /
    • 2016
  • A coplanar waveguide employing periodic 3D coupling structures (CWP3DCS) was developed for application in miniaturized on-chip passive components on silicon radio frequency integrated circuits (RFIC). The CWP3DCS showed the shortest wavelength of all silicon-based transmission line structures that have been reported to date. Using CWP3DCS, a highly miniaturized impedance transformer was fabricated on silicon substrate, and the resulting device showed good RF performance in a broad band from 4.6 GHz to 28.6 GHz. The device as was 0.04 mm2 in size, which is only 0.74% of the size of the conventional transformer on silicon substrate.

Analysis of a Communication Network for Control Systems in Nuclear Power Plants and a Case Study

  • Lee, Sung-Woo;Gwak, Kwi?Yil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.338-341
    • /
    • 2005
  • In this paper, a real-time communication method using a PICNET-NP(Plant Instrumentation and Control Network for Nuclear Power Plant) is proposed with an analysis of the control network requirements of DCS (Distributed Control System) in nuclear power plants. The method satisfies deadline in case of worst data traffics by considering aperiodic and periodic real-time data and others. In addition, the method was used to analyze the data characteristics of the DCS in existing nuclear power plant. The result shows that use of this method meets the response time requirement(100ms).

  • PDF

An Investigation of ESS(Environmental Stress Screening) Test of the DCS to be used for a thermal power plant. (발전소용 분산제어시스템의 스크리닝 시험에 관한 고찰)

  • Lee, J.H.;Ma, B.R.;Oh, Y.I.;Jung, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.871-873
    • /
    • 1999
  • According to the reports about the failure mode analysis of modules and systems, It is said that there are many early failure of system. To remove latent defects which causes early failures like that, It is necessary that screening test is performed. ESS is often used fur screening electronic equipments, and is proposed by the most powerful tool for removing latent defects of electronic equipments. [1][2] In this report, the procedure of the environmental stress screening which uses the temperature cycling stress is proposed. It is considered about environmental conditions of distributed control system(DCS) to be tested, design specifications of the system, recommended conditions of relative IEC-STD and applied conditions of similar company. ESS test was applied at the DCS to be installed in power plant. As the results of analyzing discovered problems. It was found that almost latent defects of electronic control systems was discovered early.

  • PDF

Development of KNGR-CEDMCS Prototype Using DCS for Nuclear Power Plant (원전용 분산제어시스템을 이용한 차세대 원전 제어봉 구동장치제어시스템 원형 개발)

  • Cheon, Jong-Min;Lee, Jong-Moo;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man;Shin, Jong-Ryeol
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2275-2277
    • /
    • 2004
  • Korea Next Generation Reactor(KNGR) is in the midst of being developed and will exceed Korea Standard Nuclear Power Plant(KSNP) economically. Domestic Instrumentation and Control(I&C) systems shall be applied to KNGR and the development of Control Element Drive Mechanism Control System(CEDMCS) considered as an essential part in nuclear I&C system will be dealt with in this paper. The newly developed CEDMCS has the control cabinet using the nuclear Distributed Control System(DCS) made in Korea and the power cabinet produced by our research institute and interfaced with the DCS control cabinet.

  • PDF

RTD Temperature Instrumentation Test using Distributed Control System based on UNIX (UNIX기반의 Distributed Control System을 이용한 RTD 온도계측 실험)

  • KIM S.G.;LEE S.W.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.669-672
    • /
    • 2002
  • 발전소등 대형 플랜트의 대규모 필드기기 제어용으로 많이 이용되고 있는 OVATION DCS(Distributed Control System) 시스템을 소개하고, RTD를 이용한 온도계측을 위하여 UNIX 워크스테이션을 기반으로 한 OVATION DCS 시스템의 콘트롤러 및 네트워크를 이용하여 현장 입력단 및 출력 포인터에 대한 전체 실험시스템을 구현하고, DCS 시스템의 구성 툴을 이용하여 RTD(Resistive Temperature Detector) 소자에 대한 변환계수를 산출하는 센서 Calibration 작업 및 I/O와 포인터에 대한 Configuration 구축 작업을 수행하였다 마지막으로 실질적인 온도의 측정이 정상적인지 확인하기 위해 포인터 정보 화면으로의 온도계측 값 출력 및 그래픽 디스플레이를 위한 트랜드 화면으로의 온도 출력 값을 확인하였다.

  • PDF

Consideration on the Effect of Setpoint AGC Command and Related AGC Logic in DCS (설정점 제어방식의 AGC 지령 및 발전소 DCS의 관련로직 변경방안)

  • Jeon, Dong-Hoon;Kwon, Soon-Man;Lee, Hyo-Sang;Shin, Joong-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.395-397
    • /
    • 2001
  • A new automatic generation control (AGC) signal transmission format will be adopted in the new energy management system (EMS) that KEPCO is planning to install for managing and operating the power system efficiently under the deregulation environment. Therefore, it is necessary for the power plants to make the AGC processing logic fit the new AGC signal flow format. In this work, we compare the new signal transmission scheme with the conventional one in view of its effect to the signal flow in the distributed control systems (DCS) that ale equipped in power plants to handle AGC operation. Then we propose a basic logic configuration for DCS that can be used with the new signal format. In the design of the configuration, some practical issues that should be discussed for the proper operation of the plants are considered.

  • PDF

통신재난 시나리오 분석 시스템을 이용한 DCS 전송망의 생존도 평가

  • 박구현;신용식;남택승
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1997.04a
    • /
    • pp.66-71
    • /
    • 1997
  • 생존 트래픽 비율로만 정의되는 기존의 생존도는 통신 재난시 트래픽의 상대적 중 요도와 복구기간에 대한 생존도를 적절히 반영하지 못한다. 따라서 트래픽의 상대적 중요도 에 따라 트래픽을 복구함으로써 재난의 사회적 영향을 최소화하고 복구기간을 반영하는 새 로운 평가척도로서 재난영향 평가척도를 제시한다. DCS 전송망에 대해 제시한 재난 영향 평가척도 및 기존의 생존도를 계산하기 위하여 통신재난 시나리오 분석 시스템을 이용한다. 통신재난 시나리오 분석 시스템[1]은 장애발생, 복구방법 및 복구과정 관련 시나리오등으로 구성되므로 DCS 전송망에 대한 생존도 계산이 가능하다. 통신재난 시나리오 분석 시스템을 이용하여 다양한 전송망에 대해 얻은 재난영향 평가척도 결과 및 기존 생존도 결과를 비교 하였다.

  • PDF

IPI feeding structure for the gain improvement of IFA (IFA 이득 향상을 위한 IPI 급전 구조)

  • Oh, Kyu-Jong;Son, Tae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.817-823
    • /
    • 2010
  • Design of IPI feeding structure affecting the antenna gain improvement of mobile phone was investigated. IPI feeder which based on the T matching theory increase line current for internal antenna such as IFA. So IPI feeder makes higher radiation resistance, and also increases the gain with increasing radiation efficiency. To verify IPI feeding effect, feeder is applied to conventional CDMA/DCS dual band IFA. Measurement shows that IPI-IFA has 0.5 ~ 1.4[dBi] higher gain than conventional IFA at CDMA/DCS band. Resonant frequency did not change.

Optimal Period and Priority Assignment Using Task & Message-based Scheduling in Distributed Control Systems

  • Kim, Hyoung-Yuk;Park, Hong-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.60.1-60
    • /
    • 2001
  • In recent years, distributed control systems(DCS) using fieldbus such as CAN have been being applied to process systems but it is very difficult to design the DCS in order to guarantee the given end-to-end constraints such as precedence constraints, time constraints, and periods and priorities of tasks and messages. This paper presents a scheduling method to guarantee the given end-to-end constraints. The presented scheduling method is the integrated one considering both tasks executed in each node and messages transmitted via the network and is designed to be applied to a general DCS that has multiple loops with several types of constraints, where each loop consists of ...

  • PDF

Demonstration of Modeling Process using Giant Magellan Telescope Software Development Kit

  • Han, Jimin;Pi, Marti;Filgueira, Josema;Cox, Marianne;Molgo, Jordi;Swett, Hector;Kurkdjian, Pierre;Lee, Hye-In;Ji, Tae-Geun;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.72.1-72.1
    • /
    • 2019
  • The Giant Magellan Telescope Organization (GMTO) is developing the GMT Software Development Kit (SDK) for the Observatory Control System (OCS). The SDK models a subsystem of the GMT using a Domain Specific Language (DSL) which can generate a skeleton code and validates the availability of the model automatically. The OCS includes a Device Control System (DCS) and all the devices are connected with the DCS via EtherCAT. The DCS has a component (Hardware Adapter) to communicate with EtherCAT slaves. In this presentation, we demonstrate the modeling process and describe the importance and usage plan of the SDK.

  • PDF