• Title/Summary/Keyword: DC23

Search Result 395, Processing Time 0.023 seconds

A Study on Characteristic Analysis of Single-Stage High Frequency Resonant Inverter Link Type DC-DC Converter (단일 전력단 고주파 공진 인버터 링크형 DC-DC 컨버터의 특성해석에 관한 연구)

  • Won, Jae-Sun;Park, Jae-Wook;Seo, Cheol-Sik;Cho, Gyu-Pan;Jung, Do-Young;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.16-23
    • /
    • 2006
  • This paper presents a novel single-stage high frequency resonant inverter link type DC-DC converter using zero voltage switching with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant converter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant converter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, fluorescent lamp and DC-DC converter etc.

Ion Effects of HVDC ±500 kV Double Bipole Overhead Transmission Line with Metallic Return Conductor Using Full-scale Test Line (실증시험선로를 이용한 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 이온류 특성 평가)

  • Shin, Kooyong;Kwon, Gumin;Ju, Munno;Woo, Jeong Min
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.249-256
    • /
    • 2019
  • A full-scale test line was established to verify the electrical environmental interferences caused by the HVDC ±500 kV Double Bipole overhead transmission line with metallic return conductor, which is scheduled for construction in Korea and the fullscale test was conducted for one year. And through the human perception test of the DC electric-field under the HVDC Double Bipole line, the threshold value at which the human detects DC electric field was investigated to verify the validity of the design guide for the HVDC ±500 kV Double Bipole overhead transmission line. The polarity configuration of the HVDC ±500 kV Double Bipole test line was arranged diagonally with the same polarity in terms of the electrical environment disturbance and operation. The test line utilized the 6-bundle arrangement to prevent the corona discharge taking into account the domestic social acceptability. The test results show that the HVDC ±500 kV Double Bipole transmission line generated very little corona discharge from the conductors. Therefore, both DC electric field and ion current density met the domestic design guide for DC overhead transmission lines. Also, the human perception test of DC electric fields under the test line showed that 70% of participants did not recognize the DC electric field even when exposed to 23 kV/m.

Effect of Sintering Time on Degradation Characteristics of ZPCCY-Based Varistors (ZPCCY계 바리스터의 열화특성에 미치는 소결시간의 영향)

  • 남춘우;박종아
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.6
    • /
    • pp.464-470
    • /
    • 2004
  • The electrical stability of ZPCCY-based varistors composing of ZnO-Pr$_{6}$O$_{11}$-CoO-C $r_2$ $O_3$- $Y_2$ $O_3$ ceramics were investigated in various DC accelerated aging stress with sintering times. Sintering time greatly affected electrical properties and stability. Sintering time decreased nonlinear exponent in the range of 51.2∼23.8 and increased leakage current in the range of 1.3∼5.6 ${\mu}$A. The varistor sintered for 1 h exhibited high nonlinearity, whereas relatively low stability. On the contrary, the varistor sintered for 3 h exhibited low nonlinearity, whereas relatively high stability. But the varistor sintered for 2 h exhibited not only good nonlinearity, with nonlinear exponent of 38.6 and leakage current of 3.6 ${\mu}$A but also high stability, in which the variation rates of varistor voltage, nonlinear exponent, leakage current, and dissipation factor are -0.80%, -1.81 %, +74.4%, and +0.88%, respectively.

Development of TIG-Welder DC-DC Converter Based on Fuel Cell Stack (연료전지로 구동되는 TIG-용접기용 DC-DC 컨버터 개발)

  • Min, Myung-Sik;Park, Sang-Hoon;Jeon, Byum-Soo;Won, Chung-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.48-56
    • /
    • 2009
  • This paper presents the power conversion system for TIG-welder using the fuel cell stack Generally, power supply for TIG-welder uses the front-ended diode bridge rectifier by common AC power source. In this case, power supply of TIG-welder increases in volume because of using bulky capacitor and diode-rectifier. Also, input current includes ripple and harmonics. Moreover, TIG-welder will be demand the power supply with lightweight and easy movement in the areas like as the islands and mountainous areas or the special environment are not use common AC power source. Thus, input power of the power conversion system for TIG-welder is used PEMFC(Polymer Electrolyte Membrane Fuel Cell), and the power conversion system is comprised of full-bridge converter with function of boost converter and inverter welding source, in this paper. The proposed power conversion system which is power supply for TIG-welder was verified by computer simulations and experiments.

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

The Analysis of Light Emissions on Ar DC Glow Discharge under the Atmosphere Pressure (대기압 Ar 직류 글로우 방전에서 인가전압의 파형특성에 따른 광원효율 분석)

  • SO, Soon-Youl
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.865-872
    • /
    • 2019
  • We developed a one-dimensional Ar fluid model running in DC-type applied voltage with a sine and a pulse waveform at the atmosphere pressure. We investigated the light emissions and efficiencies of ${\lambda}_{128nm}$, ${\lambda}_{727nm}$, ${\lambda}_{912nm}$ and ${\lambda}_{966nm}$ from the Ar excited particles. From the results, the light emission of ${\lambda}_{128nm}$ and ${\lambda}_{727nm}$ in the applied voltage with a sine waveform were almost two times as in DC voltage type. The shorter the switching time of applied voltage was, the more the light emissions of ${\lambda}_{128nm}$ and ${\lambda}_{727nm}$ were. We discussed the power consumption and Joule heating by charged particles.

EMC Safety Margin Verification for GEO-KOMPSAT Pyrotechnic Systems

  • Koo, Ja-Chun
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • Pyrotechnic initiators provide a source of pyrotechnic energy used to initiate a variety of space mechanisms. Pyrotechnic systems build in electromagnetic environment that may lead to critical or catastrophic hazards. Special precautions are need to prevent a pulse large enough to trigger the initiator from appearing in the pyrotechnic firing circuits at any but the desired time. The EMC verification shall be shown by analysis or test that the pyrotechnic systems meets the requirements of inadvertent activation. The MIL-STD-1576 and two range safeties, AFSPC and CSG, require the safety margin for electromagnetic potential hazards to pyrotechnic systems to a level at least 20 dB below the maximum no-fire power of the EED. The PC23 is equivalent to NASA standard initiator and the 1EPWH100 squib is ESA standard initiator. This paper verifies the two safety margins for electromagnetic potential hazards. The first is verified by analyzing against a RF power. The second is verified by testing against a DC current. The EMC safety margin requirement against RF power has been demonstrated through the electric field coupling analysis in differential mode with 21 dB both PC23 and 1EPWH100, and in common mode with 58 dB for PC23 and 48 dB for 1EPWH100 against the maximum no-fire power of the EED. Also, the EMC safety margin requirement against DC current has been demonstrated through the electrical isolation test for the pyrotechnic firing circuits with greater than 20 dB below the maximum no-fire current of the EED.

Characteristics of Piezoelectric Sensor for Fluid Impact Pressure (유체 충격 압력 측정용 압전 센서 특징)

  • Choi, Young-Myung;Kim, Hyun-Yi;Park, Jun-Soo;Kwon, Sun-Hong;Kim, Dong-Jean
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.17-22
    • /
    • 2009
  • This study presents an investigation of the characteristics of piezoelectric sensors whose main utilization is to measure impact pressure. The piezoelectric sensors were tested from several points of view. Their characteristics were investigated for repeatability, the effect of the diameter, temperature effect, water purity, flush mounting, and AC and DC coupling. Out of these, it was revealed that the temperature effect is very significant. The characteristics of the AC and DC coupling are also very important in understanding the time history of the impact pressure.

Antimicrobial Activity of The Volatile Components from Fruit Peel of Chopi(Zanthoxylum piperitum DC) (초피(Zanthoxylum piperitum DC) 과피의 휘발 성분의 항균작용)

  • 서기림;이현주;고경희
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.3
    • /
    • pp.179-183
    • /
    • 1999
  • The volatile components (essential oil) showing antimicrobial activity were extracted from the fruit peel of Zanthoxylum piperitum DC by distillation and separated by thin layer chromatography (TLC). The crude volatile components exhibited antimicrobial activity only at very high concentration. The active fraction obtained by TLC inhibited noticeably the growth of bacteria. The minimum inhibitory concentration (MIC) of the fraction were 150ppm, 300ppm, and 300ppm against Escherichia coli, Staphylococcus aureus, and Salmonella enteritidis, respectively. The components in the active fraction were identified by gas chromatography/mass spectrometry to be geranlyl acetate (60.23%), citronellal(36.01%), citronellol(3.77%), geraniol(0.46%), and cumin ldehyde(0.43%).

  • PDF