• 제목/요약/키워드: DC-type energy source

검색결과 41건 처리시간 0.022초

The study of Design Surface Treatment Obtained Metal Color in Magnesium Alloy

  • Lee, Jung Soon;Lee, Hee Myoung
    • Applied Science and Convergence Technology
    • /
    • 제26권2호
    • /
    • pp.21-25
    • /
    • 2017
  • The shape of the reflection spectrum is complex and appears to overlap with several signals, because the surface state is uneven due to the natural oxide film, so that the spectrum becomes a complicated signal shape divided into regions 1 and 2 due to diffuse reflection. On the other hand, it is seen that the reflection spectrum after PEO surface treatment is overlapped with several signals. In addition, the reflectance of the energy band varies from 1.32 to 1.46 eV. Usually, the MgO-type oxide film was observed at an energy band of ~4.2 eV. The thickness of the oxide film was increased as the DC voltage was increased by the thin film thickness meter (QuaNix; 7500M) after Plasma Electrolytic Oxidation (; PEO) surface treatment. This is because the higher the DC voltage, the easier the binding of the $OH^-$ ions in the solution solution and the $Mg^+$ ions of the magnesium alloy. An important part of the bonding of ordinary ions is the energy source (plasma) which can promote bonding. However, when a certain threshold voltage or more is applied, the material is adversely affected. The oxide film of the surface may be destroyed without increasing the thickness of the oxide film, that is, whitening of the material may occur.

LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성 (Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation)

  • 황락훈;나용주
    • 한국항행학회논문지
    • /
    • 제22권5호
    • /
    • pp.420-428
    • /
    • 2018
  • 본 논문은 태양광 발전시스템을 승압쵸퍼와 단상 펄스폭변조 전압형인버터를 사용하여 전원차단 경우나 전압변동 및 부하변동에 의한 출력전류 변화에도 일정한 출력전압을 유지하는 무정전 전원 공급장치(UPS)를 구성하였다. 본 시스템은 전압형인버터를 교류전원과 동기 시켜서 운전하고 정상상태에서는 전원으로부터 운전하고 정상상태에서는 전원으로부터 직류 측에 연결된 축전지를 태양전지를 이용한 광기전력효과와 함께 일정전압을 충전하며, 전원의 차단, 전원의 전압변동 및 부하전류의 변화에도 일정한 전압을 유지하도록 하였다. 에너지 저장장치 (ESS; energy storage system)를 상시 운영하여 공항의 기상 변화에 따른 파장별 LED 항공 유도신호 등을 효율적으로 운용하는 시스템을 구성 하였고, 전력절감효과를 얻을 수 있는 에너지절약 전원복합형 전력변환장치로 구성되어 있다. 출력은 PWM방식에 의하여 양호한 파형이 되도록 하고 전원차단과 부하의 상태의 변화 및 전원 전압 변동에도 일정한 전압으로 출력됨을 실험을 통하여 확인 할 수 있었다.

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석 (Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV)

  • 김승삼;최충석
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

인버터식 X선장치의 관전압 맥동율 개선에 관한 연구 (A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator)

  • 이성길;임홍우;조금배;정수복;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

Dynamic Analysis and Controller Design for Standalone Operation of Photovoltaic Power Conditioners with Energy Storage

  • Park, Sun-Jae;Shin, Jong-Hyun;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2004-2012
    • /
    • 2014
  • Energy storage devices are necessary to obtain stable utilization of renewable energy sources. When black-out occurs, distributed renewable power sources with energy storage devices can operate under standalone mode as uninterruptable power supply. This paper proposes a dynamic response analysis with small-signal modeling for the standalone operation of a photovoltaic power generation system that includes a bidirectional charger/discharger with a battery. Furthermore, it proposes a DC-link voltage controller design of the entire power conditioning system, using the storage current under standalone operation. The purpose of this controller is to guarantee the stable operation of the renewable source and the storage subsystem, with the power conversion of a very efficient bypass-type PCS. This paper presents the operating principle and design guidelines of the proposed scheme, along with performance analysis and simulation. Finally, a hardware prototype of 1-kW power conditioning system with an energy storage device is implemented, for experimental verification of the proposed converter system.

온도보상회로를 부착한 개방형 전류측정기의 특성 (Characteristics of Open-Loop Current Sensor with Temperature Compensation Circuit)

  • 구명환;박주경;차귀수;김동희;최종식
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8306-8313
    • /
    • 2015
  • 개방형 전류측정기는 DC 모터 콘트롤러, AC 가변 콘트롤러, UPS(Uninterruptible Power System)에 주로 사용되며 최근 신재생 에너지의 성장과 전력망의 스마트 그리드화로 인하여 활용성이 점차 확대되고 있다. 이러한 신재생 에너지의 성장으로 관련 핵심기술의 보유여부가 중요해지고 있으며 대부분 수입에 의존하고 있는 개방형 전류측정기의 국산화 및 관련 기술의 확보를 필요로 한다. 본 논문에서는 일반 산업용 개방형 전류측정기의 제작과정과 특성을 측정한 결과를 기술하였다. 개방형 전류측정기를 구성하는 C형 철심의 공극자장분포 해석 및 형상 설계, 홀센서의 선정 및 특성시험, 정전류 전원공급회로와 신호처리회로의 회로설계 과정을 기술하며 DIP(Dual In-line Package) type과 SMD (Surface Mount Device) type의 100A급 개방형 전류측정기를 제작하고 특성을 측정했다. 제작된 전류측정기로 0~100A 범위에서 통전 실험을 실시한 했고 직류전류와 60Hz의 교류전류에서 특성을 측정한 결과 정밀도 오차 2% 이내, 선형도 오차 2% 이내의 성능을 만족하였다. 또한 부 특성 온도계수를 갖는 NTC(Negative Temperature Coefficient) 서미스터를 이용한 온도보상회로를 사용하여 $-35{\sim}100^{\circ}C$의 범위에서 온도보상 효과를 확인하였다.

마이크로그리드용 4-Leg 방식 PCS의 각상 개별제어 알고리즘에 관한 연구 (Single-phase Control Algorithm of 4-Leg type PCS for Micro-grid System)

  • 김승호;최성식;김승종;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.817-825
    • /
    • 2017
  • AC 방식 마이크로그리드는 다양한 DC/AC 인버터를 AC 네트워크에 연결하여, DC 방식 마이크로그리드의 약점을 극복 하고 있다. 그러나 소규모 마이크로그리드에서 일반적으로 발생하는 심각한 부하 불평형 현상에 의하여, AC 마이크로그리드 시스템의 성능을 약화시킬 수 있다. 이것은 마이크로그리드 내의 불평형 부하로 인하여 상별 에너지 흐름과 전압조정기능이 제한되기 때문이다. 이러한 불평형 전압문제를 해결하기 위하여, 3상 4-Leg 방식의 인버터가 제안되고 있지만, 이를 안정적으로 운용할 수 있는 제어알고리즘이 미비한 실정이다. 따라서, 본 논문에서는 부하 불평형에 의해서 발생하는 인버터의 전압 불평형 문제를 해결하고 안정적으로 제어하기 위하여 d-q제어를 기반으로 3상4선식 인버터의 각상 개별제어 알고리즘을 제안하였다. 또한, 이 알고리즘을 바탕으로 Matlab/Simulink를 이용하여 4-Leg 방식의 전압제어기 모델링을 수행하였다. 이 모델링과 250KW급 시험장치를 바탕으로 인버터의 출력전압 제어특성을 분석한 결과, 정상상태에서는 기존의 방식과 비슷한 특성을 보이지만, 과도상태에서는 제안한 각상 개별제어 방식이 기존의 방식보다 안정적으로 동작하여 제안한 방식의 유용성을 확인할 수 있었다.

근접장현미경을 이용한 폴리머박막 나노리쏘그라피 공정의 특성분석 (Characteristics of Nanolithography Process on Polymer Thin-film using Near-field Scanning Optical Microscope)

  • 권상진;김필규;장원석;정성호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.590-595
    • /
    • 2004
  • The shape and size variations of the nanopatterns produced on a positive photoresist using a near-field scanning optical microscope(NSOM) are investigated with respect to the process variables. A cantilever type nanoprobe having a 100nm aperture at the apex of the pyramidal tip is used with the NSOM and a He-Cd laser at a wavelength of 442nm as the illumination source. Patterning characteristics are examined for different laser beam power at the entrance side of the aperture( $P_{in}$ ), scan speed of the piezo stage(V), repeated scanning over the same pattern, and operation modes of the NSOM(DC and AC modes). The pattern size remained almost the same for equal linear energy density. Pattern size decreased for lower laser beam power and greater scan speed, leading to a minimum pattern width of around 50nm at $P_{in}$ =1.2$\mu$W and V=12$\mu$m/. Direct writing of an arbitrary pattern with a line width of about 150nm was demonstrated to verify the feasibility of this technique for nanomask fabrication. Application on high-density data storage using azopolymer is discussed at the end.

  • PDF

Performance Analysis of Cost Effective Portable Solar Photovoltaic Water Pumping System

  • Parmar, Richa;Banerjee, Chandan;Tripathi, Arun K.
    • Current Photovoltaic Research
    • /
    • 제9권2호
    • /
    • pp.51-58
    • /
    • 2021
  • Solar water pumping system (SWPS) is reliable and beneficial for Indian farmers in irrigation and crop production without accessing utility. The capability of easy installation and deployment, makes it an attractive option in remote areas without grid access. The selection of portable solar based pumps is pertaining to its longer life and economic viability due to lower running cost. The work presented in this manuscript intends to demonstrate performance analysis of portable systems. Consequent investigation reveals PSWS as the emerging option for rural household and marginal farmers. This can be attributed to the fact that, a considerable portion (around 45.7%) of the country's land is farmland and irrigation options are yet to reach farmers who entirely rely on rain water at present for harvesting of the crops. According to census 2010-2011 tube wells are the main source for irrigation amongst all other sources followed by canals. Out of the total 64.57-million-hectare net irrigation area, 48.16% is accounted by small and marginal holdings, 43.77% by semi-medium and medium holdings, and 8.07% by large holdings. As per 2015-16 census data, nearly 100 million farming households would struggle to make ends meet. The work included in this manuscript, presents the performance of different commercial brands and different technologies of DC surface solar water micro pumping systems have been studied (specifically, the centrifugal and reciprocating type pumps have been considered for analysis). The performance of the pumping systems has been analyzed and data is evaluated in terms of quantity of water impelled for specific head. The reciprocating pump has been observed to deliver the best system efficiency.