• Title/Summary/Keyword: DC-AC inverter

Search Result 458, Processing Time 0.023 seconds

Improvement of Naval Combat System UPS under Abnormal Transients (비정상 과도상태에서의 해군 전투체계 UPS 개선)

  • Kim, Sung-Who;Choi, Han-Go
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.97-103
    • /
    • 2018
  • This paper addresses an improved naval combat UPS(Uninterruptable Power Supply) system under abnormal transients. Previously, thermistor and varistor elements were used to cope with transient overvoltage and overcurrent, however the UPS was frequently unavailable because it was vulnerable to abnormal transient voltage generated during system operation. In order to overcome this problem and protect UPS system, this paper proposes an input power cut-off circuit that detects the initial input power and abnormal transient voltage generated during operation, improvement of power control sequence, and a method to prevent malfunction of an inverter and CPU. The UPS system implementing the proposed method was simulated by input power variable test using programmable AC/DC generator, and finally validated its reliability and stability through field tests by mounting on multifunctional console of naval combat system.

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.

Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation (5kW 급 주택용 고분자 연료전지 시스템)

  • Yang, Tae-Hyun;Park, Gu-Gon;Yoon, Young-Gi;Lee, Won-Yong;Yoon, Wang-Lai;Kim, Chang-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

High Power Factor Converter for Electric Vehicle Chargers (전기자동차 충전기용 고역율 콘버어터 회로)

  • 김영민;이수원;모창호;유철로
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.33-38
    • /
    • 1997
  • Generally, various semiconductor switching devices for power systems are used in battery chargers for electric vehicle. When these used, it takes the problems of transient-current or distortion of waveforms in power systems near by battery chargers because of harmonics and large peak-current, low power factor, etc., caused by the non-linearity of these devices. Recently, power factor control, line current peak-cut, harmonics reduction which was ignored in past is more and more important. In this paper, to solve those problems we will improve the characteristics of voltage rising and propose the high power factor converter circuit for battery chargers. Our proposed system convert commutated voltage to AC resonant wave in high frequency inverter and rectify the link voltages passed high-frequency transformer and transfer the DC voltages. Especially, the effect using these converter system can be improved very large by power factor control and we have to verify the possibilities of improvement through the experiment of Pb-Acid battery application.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Adaptive Regulators for Quality Assurance in Resistance Welding (MFDC 저항용접의 적응제어 및 SPC 기능 고찰)

  • Lee, Yong-Ki
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.119-119
    • /
    • 2009
  • 인버터 DC 저항용접의 적용성 증대 : 인버터 DC 저항용접 공법이 SPOT, PROJECTON, SEAM, BUTT 등의 공정에 다양하게 적용되어 저항용접 현장에서 고효율, 친환경적 용접 환경을 만드는데 일조 하고 있다. 특히 자동차의 경량화, 충돌내성 증대, 진동 및 내구성 증대, 공간활용 극대화, 새로운 Design 개념 적용 등의 산업전반에 걸쳐 나타나는 신 Trends로 고 장력 철재의 적용 범위가 확대되고 HSS(High Strength Steel), EHSS(Extra High Strength Steel), UHSS (Ultra High strength Steel ; Hot - Formed Steel )등 다양한 철판의 SPOT 저항용접이 필요하게 되었다. 기존의 AC 단상용접의 전력 특성 상 통전 중 무 통전 시간 과 높은 PEAK 전력, 단상 대 전력 소모로 인한 전력 DROP 등의 문제로 인하여 신소재의 용접 시 매우 많은 Spatter가 발생하고, 높은 용접품질의 확보가 어려워 지므로 이를 대체하기 위한 공법으로 MFDC ( 인버터 DC 저항용접공법 )이 적용되고 있다. 인버터 DC 저항용접의 적응제어 : MFDC라는 높은 효율의 용접 전력원이 확보 됨에도 불구하고 용접현장에서는 원 자재, 도금 등의 품질 산포, 프레스 물의 가공산포, 공기압 산포, 전극 과열 및 마모 등의 요인에 의하여 저항용접 산포가 발생하고 있다. 이는 인위적인 조작이 어렵고 불규칙적이며, 어디서나 산재하고 있는 문제이다. 이를 용접전력 제어 법으로 개선하여 일정한 용접성을 확보하기 위한 노력이 적응제어 기법이다. 정 전류, 정 전력 제어는 정량 제어로 용접 물을 비롯한 용접부의 변화와는 관계없이 설정된 일정량의 전력을 공급하기만 하는데 반하여 적응제어는 적절한 용접 작업 시의 용접 물의 상태, 전극의 가압, 표면 상태 등에 따른 변화 페턴을 기억하고 이후 진행되는 용접에 대하여 정상 페턴과의 차이를 감지 이를 보상하므로 고품질의 용접성을 보장하는 제어기법이다. 따라서 다양한 용접 산포 유발 요인에 의해 용접부의 변화가 발생한다 하여도 그 변화를 감지 하고 적절한 용접전력을 공급한다면 고품질의 용접성을 확보하는데 유용한 공법이 될 수 있다. 인버터 DC 저항용접의 SPC 관리 : SPOT 용접 시 획득할 수 있는 다양한 파라메터에 대하여 모니터링 하고 이 자료를 data 화 하여 품질 관리에 응용하게 되면 양산라인에서 반복적으로 발생되는 문제점을 확인 할 수 있고 이를 통계적 방법으로 추적 개선해 나간다면 용접 불량 감소 및 생산성 향상에 도움이 되며 작업자의 공정 능력 향상 및 기업의 기술축적에도 높은 기여를 할 수 있을 것이다. 용접 적응제어와 다양한 파라메터 모니터링이 한 system에서 이루어 질 때 높은 용접성 확보와 불량률 감소, 원가절감, 생산성 향상 등의 효과가 극대화 될 것이다.

  • PDF

A Study on the Inverter performance by Simulated Converter (시뮬레이터 컨버터에 의한 인버터 성능시험에 관한 연구)

  • Jho, J.M.;Jho, J.H.;Kim, S.N.;Lee, S.H.;Oh, S.H.;Lee, H.G.;Kim, Y.J.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.983-985
    • /
    • 2002
  • This paper is the machine that is able to estimate a new built power convertor in a production line. Generally, this machine test can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. But the proposal system is controlled to create some specific load characteristic needed for the test without any mechanical equipment. The suggested test stand consists only of a converter to be test and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. And then, to obtain a superior characteristic for dynamic reference used the feedforward control.

  • PDF

An Identification Method of Secondary Resistance Based on Quick Torque Control System of Induction Motors (피드포워드적 수법에 근거한 유도전동기의 토크 속응제어계에 있어서 2차저항 동정법)

  • Jeong, Seok-Kwon;Yang, Joo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.267-269
    • /
    • 1996
  • Servo systems became indispensable to applications such as industrial robots and numerically controlled machinery. Especially, induction motor drives are widely used as ac-servo system owing to the fact that it is maintenance-free. At the present time, Quick torque control methods such as vector control have been employed that enables an induction motor to attain as quick torque response as a dc motor. However, these methods can not be realized without knowing several motor parameters accurately, because the methods need them to calculate flux or voltage command. Most of all, secondary resistance has to be identified accurately, because it's value varies greatly for operation of induction motors. In this paper, a new identification method of secondary resistance based on quick torque control system of induction motors is proposed. The proposed method is derived theoretically from motor circuit equation and can be realized very simply by detecting primary current and voltage command of the motor. Through the numerical simulation considered using PWM inverter, the validity of the proposed method was successfully confirmed.

  • PDF