• Title/Summary/Keyword: DC-AC 인버터

Search Result 246, Processing Time 0.031 seconds

Regeneration inverter system for DC traction system (직류 지하철 급전시스템용 회생인버터 시스템)

  • Cho, Kee-Hyun;Jang, Su-Jin;Kim, Jong-Yoon;Won, Chung-Yuen;Kim, Yong-Ki
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.28-32
    • /
    • 2007
  • In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.

  • PDF

Utility interactive PV system using buck-boost chopper and partial resonant Inverter (승강압초퍼와 부부공진 인버터를 이용한 계통연계형 태양광 발전시스템)

  • 고강훈;이현우;김영철;정명웅;홍두성
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.278-281
    • /
    • 1999
  • In a utility interactive photovoltaic system, a PWM inverter is used for the connection between the photovoltaic arrays and the utility. The DC current becomes pulsated causes the distortion of the AC current waveform. This paper presents the reduced pulsation of DC input current by operating the inverter with buck-boost chopper in the discontinuous conduction mode. The DC current with contains harmonics component is analyzed by means of separating into two terms of a ripple component and a direct component. The constant DC current without pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provide a sinusoidal AC current for domestic loads and the utility line with unity power factor.

  • PDF

A Study on the Power Factor Improvement of DC Power Regenerating Systems (직류전력 회생시스템의 역률개선에 관한 연구)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • This paper proposes a new control scheme for the power factor improvement of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three-phase square-wave inverters and composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the regenerating system are not sinusoidal. However, regenerated complex power is analyzed on the basis of fundamental components and thus the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero even for nonsinusoidal cases. To verify the validity of the proposed control scheme, computer simulations are carried out. And the results show that the power factor is theoretically higher than 0.99.

  • PDF

Application of Multi-Level Inverter for Improvement of Power Quality in AC 25[kV] Electrified Railway System (교류전기철도 전력품질 향상을 위한 직.병렬 보상장치 적용에 관한 연구)

  • Park, Soo-Cheol;Song, Joong-Ho;Chang, Sang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.131-141
    • /
    • 2007
  • This paper proposes analysis on new equipment for power quality in electric railway. The proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer. We verified the proposed equipment using the PSCAD/EMTDC and the calculation results from the proposed approach are widely described in the paper.

Performance Analysis of High Frequency Power Conversion Topologies for Remote Plasma Generators (원격 플라즈마 발생장치를 위한 고주파 전력변환 토폴로지의 성능 분석)

  • Sung, Won-Yong;Chae, Hun-Gyu;Koo, Keun Wan;Lee, Byoung Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.147-148
    • /
    • 2016
  • 본 논문에서는 원격 플라즈마 발생장치 (Remote Plasma Generator, RPG)에 적용하기 위한 공진형 토폴로지에 대해 비교한다. 원격 플라즈마 발생장치는 AC-DC 정류기, DC-AC 인버터, 공진탱크, 플라즈마 발생용 리액터, 점화장치로 구성되며, 이는 기존의 SMPS와 유사한 구성이다. 하지만 플라즈마 부하는 기존의 전력전자 어플리케이션들과는 달리 점화조건과 플라즈마 유지 조건을 충족시켜야 한다는 특징이 있다. 따라서 본 논문에서는 각 공진형 토폴로지들의 특성 비교 분석을 통해 원격 플라즈마 발생장치에 대한 적용 가능성에 대한 분석을 수행하였으며, 시뮬레이션을 통해 검증하였다.

  • PDF

The considerations of a High Frequency DC-AC Inverter in a Short Range Wireless Power Transfer Applications (근거리 무선전력전송용 고주파 DC-AC 인버터 회로 고찰)

  • Park, Jae-Hyun;Kim, Chang-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.37-38
    • /
    • 2010
  • For MHz-class high frequency inverter in wireless power transfer applications, the voltage/current surges can be occurred in power stage when driving on the inverter. And also, the high-frequency oscillations can be produced at a high switching frequency due to the parasitic elements. The voltage and current stresses of the switching devices lead to the switching losses. The efficiency of the high frequency inverter will be reduced. And the inverter circuit with the sudden voltage and current fluctuations also generates the noise such as the EMI. Zero voltage, zero current switching technique can be used to reduce the switching loss and the noise. The high power density and high efficiency can be obtained. In this paper, the high-frequency inverter for short-range wireless power transfer applications was discussed. The feasible inverter circuit is analyzed in the circuit operating characteristics and the results are verified by the simulation.

  • PDF

Design of High Voltage Cascaded NPC H-Bridge Inverter (고전압 Cascaded NPC H-Bridge 인버터 설계)

  • Hyun, Seung-Wook;Noh, Yong-Su;Hyon, Byong Jo;Choi, Jun-Hyuk;Kim, Jin-Hong
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.290-291
    • /
    • 2018
  • This paper proposed design method of DC link capasitor and leakage inductance of transformer with high voltage cascaded NPC H-bridge inverter. DC link capacitor is designed based on the ripple power between input AC power and output AC power, and leakage inductance of transformer is designed based on FFT table of unipola PWM with NPC H-bridge inverter. The proposed design method is verified by simulation results of 6.6[kV], 1.2[MW] Cascaded NPC H-bridge inverter.

  • PDF

Design of Three-port Flyback Inverter for Active Power Decoupling (능동 전력 디커플링을 위한 3권선 방식의 플라이백 인버터 설계)

  • Kim, Kyu-Dong;Kim, Jun-Gu;Lee, Tae-Won;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.486-487
    • /
    • 2012
  • In this paper, novel three-port active power decoupling (APD) method for applying 250[W] micro-inverter. This type using third port for active power decoupling stores the surplus energy and supplies sufficient energy to grid. Conventional decoupling circuit is applied in single phase grid connected micro-inverter especially single-stage configuration like flyback-type DC-AC inverter. In this passive power decoupling method, electrolytic capacitor with large capacitance is needed for decoupling from constant DC power and instantaneous AC power. However the decoupling capacitor is replaced with film capacitor by using APD, thus the overall system can achieve smaller size and long lifespan. Proposed three-port flyback inverter is verified by design and simulation.

  • PDF

PWM Control of Line Commutated Inverter With GTO Forced Commutation (GTO강제 전류를 병용한 타려식 인버터의 PWM제어)

  • 정연택;성세진;심재명
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.610-616
    • /
    • 1989
  • The line commutated inverter with GTO forced commutation is described in this paper. The presented circuit has one bypass GTO inserted in DC power side line commutated thyristor inverter. The extended commutation region with additional one GTO-commutation is clearly shown. Also, a new PWM pattern is presented to decrease the effects of harmonics for commutation. A criterion for designing the AC filter parameters to decrease harmonics of AC part is given. The simulation and experimental results clearly show that the proposed circuit can be adapted in the application of regeneration.

  • PDF

Design of High-Efficiency Full-Bridge Converter and Inverter for ESS (ESS용 고효율 풀브리지 컨버터 및 인버터 설계)

  • Jung, Jae-Hun;Lee, Chang-woo;Choi, Jin-ku
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.685-688
    • /
    • 2015
  • A phase-shift full-bridge converter is widely used conventional converter. If the input power change in the variation of the output voltage, there is a time interval freewheeling according to a duty change. This is a factor of reducing the efficiency. In this paper, we propose a method for improving the efficiency of the converter/inverter systems that require high efficiency in the ESS. The proposed method was used for the duty control for solving the fail problem ZVS(Zero Voltage Switching) in Freewheeling interval. The proposed method was verified by experiments.

  • PDF