• Title/Summary/Keyword: DC transmission

Search Result 477, Processing Time 0.028 seconds

FDTD Analysis of Lossy Multiconductor Transmission Lines Terminated in Linear Loads (선형소자로 종단된 손실이 있는 다중 전송선의 FDTD 해석)

  • 박범준;주재철;이형영;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.419-428
    • /
    • 2000
  • Multiconductor transmission line(MTL) equations are solved by FDTD(Finite-Difference Time-Domain) method to predict crosstalk and fields to transmission line coupling on lossy multiconductor transmission lines terminated in arbitrary linear loads. Skin effect losses as well as dc losses are included in the analysis. In order to increase computational efficiency, the convolution integral of internal impedance of conductors and the line currents is computed by using Prony method. For boundary conditions of MTLs terminated in linear loads, state-variable formulation is adopted. The simulated results by FDTD method are compared with the measured ones obtained by using TEM cell. The predictions are in good agreement with the measurements. In addition, it has been found that skin effect losses as well as dc losses of the conductors should be included for accurate predictions on relatively high loss transmission lines such as PCB. It has also been found that dc losses and skin-effect losses affect late-time responses and early-time responses, respectively.

  • PDF

An Information Transmission Method of the DC Switchgear for Light Railway Vehicle (경량전철용 직류배전반의 정보 전송방식)

  • Lee, H.D.;Kim, S.N.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

Device Feature and Application Status for Light Triggering Thyristor(LTT) in HVDC Transmission (HVDC 송전용 광구동 사이리스터(LTT)를 위한 소자특성 및 응용의 요구)

  • Zhang, C.L.;Kim, S.C.;Kim, E.D.;Kim, H.W.;Seo, K.S.;Bhang, W.;Cheong, K.Y.;Kim, N.K.;Luo, J.Q.;Bai, J.B.;Wang, X.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.397-400
    • /
    • 2004
  • The design concept for 8kV light triggering thyristor(LTT) with integrated BOD was discussed here in detail. The trade-off between light triggering input source againsthigh dV/dt limitation has been treated via grooved P-base for gate design. The main application point used for high voltage DC transmission(HVDC) was represented.

  • PDF

Feasibility Study of the application of HVDC System to Domestic Power System ' Design of the HVDC system for Sinokchun-Sedaegu 345kV Transmission line (직류변환 송전방식 국내도입 타당성 검토 : 신옥천-서대구 345kV송전선로 1회선 직류변환 설계)

  • Kim D. J.;Yoon J. Y.;Yang K. H.;Moon Y. H.;Lee D. I.;Shin G. Y.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.186-188
    • /
    • 2004
  • This paper describes the feasibility study of HVDC system application to KEPCO power system for increasing power transfer capability or the flexibility of power delivery from one area to the other using the existing transmission line. This paper assumes the 345kV transmission line connecting between Shinokchun and Sedaegu to be converted to the DC line by replacing the AC insulator with that of DC. Then, the HVDC bipole system of 1000MVA with $\pm300kV$ is designed and the contingency studies are carried out.

  • PDF

AC and DC Microgrids: A Review on Protection Issues and Approaches

  • Mirsaeidi, Sohrab;Dong, Xinzhou;Shi, Shenxing;Wang, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2089-2098
    • /
    • 2017
  • Microgrid is a convenient, reliable, and eco-friendly approach for the integration of Distributed Generation (DG) sources into the utility power systems. To date, AC microgrids have been the most common architecture, but DC microgrids are gaining an increasing interest owing to the provision of numerous benefits in comparison with AC ones. These benefits encompass higher reliability, power quality and transmission capacity, non-complex control as well as direct connection to some DG sources, loads and Energy Storage Systems (ESSs). In this paper, main challenges and available approaches for the protection of AC and DC microgrids are discussed. After description, analysis and classification of the existing schemes, some research directions including coordination between AC and DC protective devices as well as development of combined control and protection schemes for the realization of future hybrid AC/DC microgrids are pointed out.

Design of 20 W Class-E Amplifier Including Protection for Wireless Power Transmission at ISM 13.56 MHz (보호 회로를 포함한 무선 전력 전송용 ISM 13.56 MHz 20 W Class-E 앰프 설계)

  • Nam, Min-Young;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.613-622
    • /
    • 2013
  • In this paper, an inductive clamping class-E power amplifier has been tested for wireless power transmission at ISM band, 13.56 MHz. The implemented power amplifier is designed to operate stably without destroying power transistor in wireless power transmission system which basically keeps not to align between a transmitting antenna and a receiving antenna. The power amplifier is also designed to enhance harmonic filtering characteristic. The amplifier was tested with a DC supply voltage of 28 V and input power of 25 dBm at 13.56 MHz. The test results show the output power level of 43 dBm, the difference power level between fundamental frequency and second harmonic frequency of more than 55 dBc, the dc current consumption of 830 mA, and the high power-added efficiency of 85 %. Finally, the implemented power amplifier operated normally with 830 mA DC current consumption from 28 V source when the two antennas were aligned, and the power transmission was successful. But when the two antennas were not aligned, its DC current consumption automatically decreased down to 420 mA to protect the switching transistor.

Clamping-diode Circuit for Marine Controlled-source Electromagnetic Transmitters

  • Song, Hongxi;Zhang, Yiming;Gao, Junxia;Zhang, Yu;Feng, Xinyue
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.395-406
    • /
    • 2018
  • Marine controlled-source electromagnetic transmitters (MCSETs) are important in marine electromagnetic exploration systems. They play a crucial role in the exploration of solid mineral resources, marine oil, and gas and in marine engineering evaluation. A DC-DC controlled-source circuit is typically used in traditional MCSETs, but using this circuit in MCSETs causes several problems, such as large voltage ringing of the high-frequency diode, heating of the insulated-gate bipolar transistor (IGBT) module, high temperature of the high-frequency transformer, loss of the duty cycle, and low transmission efficiency of the controlled-source circuit. This paper presents a clamping-diode circuit for MCSET (CDC-MCSET). Clamping diodes are added to the controlled-source circuit to reduce the loss of the duty ratio and the voltage peak of the high-frequency diode. The temperature of the high-frequency diode, IGBT module, and transformer is decreased, and the service life of these devices is prolonged. The power transmission efficiency of the controlled-source circuit is also improved. Saber simulation and a 20 KW MCSET are used to verify the correctness and effectiveness of the proposed CDC-MCSET.

Switching Frequency Reduction Method for Modular Multi-level Converter Utilizing Redundancy Sub-module (예비 서브모듈을 활용한 모듈형 멀티레벨 컨버터의 스위칭 주파수 저감 기법)

  • Lee, Yoon-Seok;Yoo, Seung-Hwan;Choi, Jong-Yun;Park, Yong-Hee;Han, Byung-Moon;Yoon, Young-Doo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1640-1648
    • /
    • 2014
  • This paper proposes a switching frequency reduction method for MMC (Modular Multilevel Converter) utilizing redundancy operation of sub-module, which can offer reduction of voltage harmonics and switching loss. The feasibility of proposed method was verified through computer simulations with PSCAD/EMTDC software. Based on simulation analysis, a hardware scaled-model of 10kVA, DC-1000V MMC was designed and manufactured in the lab. Various experiments were conducted to verify the feasibility of proposed method in the actual hardware system. The hardware scaled-model can be effectively utilized for analyzing the performance of MMC according to the modulation scheme and redundancy operation.

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

Improved Coded Mark Inversion for the Passive Radio Frequency Transmission System of the Electronic Time Fuze

  • Xiong, Dong;Zeng, Xiaoping;Zhao, Xiaogang
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.348-350
    • /
    • 2009
  • To fit the limited volume and power consumption of the passive radio frequency transmission system of the electronic time fuze, an improved coded mark inversion (CMI) is proposed in this letter. From the performance analysis, the energy transmission efficiency of this encoding method is at least 50% higher than that of CMI and NRZ. Finally, the experiment results show that by adopting this improved CMI, the change of DC voltage through magnetic coupling is lower than 0.2 V when the accuracy of data transmission is above 99.5%.

  • PDF